GEYA GYM9H-Z DC Solar Mini Circuit Breaker Instruction Manual

Model: GYM9H-Z MCB

Brand: GEYA

1. Introduction

The GEYA GYM9H-Z DC miniature circuit breaker adopts a dual-manifold manifold design, which makes wiring more convenient. The product is marked with a transparent sheet on the outside and features overload protection, short-circuit protection, isolation protection and other functions. The wiring capacity can reach 25mm ², making it suitable for DC screens, energy storage devices and other DC non-compliant applications.

2. Safety Information

  • Always ensure power is disconnected before installation or maintenance.
  • Installation should be performed by qualified personnel in accordance with national and local electrical codes.
  • Do not operate the circuit breaker with wet hands.
  • Ensure proper grounding where required.
  • Verify correct voltage and current ratings before connecting to any circuit.
  • This device is designed for DC systems. Do not use it in AC systems unless explicitly stated for specific models.

3. Product Features

  • Standard Compliance: Meets IEC/EN60947-2, IEC/EN60947-2 Annex P, GB14048.2, GB14048.2 Annex P.
  • Dual-Manifold Design: Facilitates convenient wiring.
  • Transparent Identification: Clear visibility of status.
  • Contact Position Indication: Provides visual confirmation of contact status.
  • High Wiring Capacity: Supports up to 25mm² wiring.
  • Protection Functions: Overload protection, short-circuit protection, and isolation.
  • Versatile Application: Suitable for DC screens, energy storage devices, communication, and photovoltaic systems.

4. Technical Specifications

Table 1: Electrical Characteristics
CharacteristicValue
Rated Current (In)1, 2, 3, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63A
Rated Voltage (Ue) - 1P48, 60, 125, 150VDC
Rated Voltage (Ue) - 2P110, 125, 250, 300VDC
Rated Voltage (Ue) - 3P450VDC
Rated Voltage (Ue) - 4P600VDC
Tripping CurvesB, C
Breaking Capacity6kA
Poles1P, 2P, 3P, 4P
Mechanical Life20000 times
Electrical Life1500 times
Wiring Capacity1-25mm² (Copper wire hard line), 1-16mm² (Soft wire or ferrule terminal)

Temperature Compensation

When the ambient temperature is not the baseline temperature of 30°C, the reference correction coefficient is as follows:

Table 2: Current Correction Factor
Ambient Temperature-20°C-10°C0°C10°C20°C30°C40°C50°C60°C
Current Correction Factor1.251.21.151.101.051.000.950.900.85

5. Installation

5.1. Mounting

The GYM9H-Z DC circuit breaker is designed for DIN rail mounting. Ensure a secure fit on the rail.

5.2. Wiring

Connect the DC power supply to the upper terminals and the DC load to the lower terminals. The circuit breaker supports universal positive and negative poles, allowing flexible wiring. Ensure all connections are tight to prevent loose contacts and overheating.

Video: Demonstrates connecting the DC power supply to the upper terminals and the DC load to the lower terminals of the circuit breaker.

5.3. Wiring Diagrams and Dimensions

Refer to the diagrams below for detailed wiring configurations and physical dimensions for 1P, 2P, 3P, and 4P models.

Technical Specification and Outline Overall And Installing Dimensions for GEYA GYM9H-Z DC MCB
Figure 1: Technical Specifications and Outline Overall and Installing Dimensions for 1P, 2P, 3P, and 4P models.
Universal Positive and Negative Poles for GEYA GYM9H-Z DC MCB
Figure 2: Illustration of universal positive and negative poles for flexible wiring.
Dimensions for 1P GEYA GYM9H-Z DC MCB
Figure 3: Dimensions for the 1P model.
Dimensions for 2P GEYA GYM9H-Z DC MCB
Figure 4: Dimensions for the 2P model.

6. Operation

To operate the circuit breaker, use the toggle switch on the front panel:

  • ON: Push the toggle switch upwards to close the circuit and allow current flow.
  • OFF: Push the toggle switch downwards to open the circuit and interrupt current flow.
  • Tripped: If an overload or short circuit occurs, the toggle switch will automatically move to an intermediate position, indicating a trip. To reset, first move the switch fully to the OFF position, then back to ON.

The transparent identification window provides a visual indication of the contact position (ON/OFF/TRIPPED).

7. Maintenance

Regular maintenance ensures optimal performance and longevity of the circuit breaker.

  • Periodic Inspection: Inspect the circuit breaker and its connections regularly (e.g., every 6-12 months) for any signs of damage, loose connections, or discoloration.
  • Cleaning: Keep the circuit breaker free from dust and debris. Use a dry, soft cloth for cleaning. Do not use solvents or abrasive cleaners.
  • Connection Check: Ensure all terminal screws are tight. Loose connections can cause overheating and potential hazards.
  • Functionality Test: Periodically test the ON/OFF switching and observe if the trip mechanism operates correctly under simulated fault conditions (if safely possible and recommended by a professional).
  • Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent premature aging or malfunction.

8. Troubleshooting

Table 3: Common Issues and Solutions
ProblemPossible CauseSolution
Circuit breaker trips frequentlyOverload, short circuit, ground fault, incorrect ratingCheck connected load for overcurrent. Inspect wiring for short circuits or ground faults. Ensure the circuit breaker's rating matches the circuit requirements. Consult an electrician if issues persist.
Circuit breaker does not resetPersistent fault, internal damageEnsure the fault condition is cleared. Try moving the switch fully to OFF before attempting to reset to ON. If it still doesn't reset, the unit may be damaged and require replacement.
Overheating at terminalsLoose connections, undersized wires, excessive currentTighten all terminal screws. Verify wire gauge is appropriate for the current. Check for overcurrent conditions.

9. User Tips

  • For solar applications, always ensure the circuit breaker is rated for the maximum open-circuit voltage (Voc) of your solar array, not just the operating voltage.
  • Consider using a higher current rating than your typical operating current to account for potential surges, but always stay within safe limits for your wiring.
  • Regularly check the transparent window for the contact position indicator to quickly identify if the breaker has tripped.

10. Additional Documents

For a comprehensive guide and detailed diagrams, you can refer to the official user manual:

User manual (PDF): View PDF Manual

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.