Aideepen KWS-DC26

Rate this product if you’ve used it
Contents

KWS-DC26 DC 8-80V Multifunctional LCD Digital Battery Charger Tester User Manual

Brand: Aideepen | Model: KWS-DC26

1. Introduction

The KWS-DC26 is a newly upgraded, multifunctional LCD digital battery charger tester designed for precise measurement of voltage, current, power, and energy consumption in DC circuits. It features a high-resolution color LCD screen for clear display of measured values and offers bidirectional measurement, data recording, and timing functions. Its robust design and ease of operation make it a reliable tool for various applications.

KWS-DC26 Multifunctional LCD Digital Battery Charger Tester displaying voltage, current, power, energy, time, and temperature.
Figure 1: KWS-DC26 Multifunctional LCD Digital Battery Charger Tester

2. Key Features

  • Color LCD Screen: Provides accurate and clear display of measured values including voltage, current, power, and energy consumption.
  • Bidirectional Measurement: Capable of measuring power flow in both directions.
  • Data Recording: Records measurement data for analysis.
  • Timing Function: Includes a built-in timer for monitoring duration.
  • Temperature Display: Equipped with a temperature probe for real-time monitoring of charging product temperature, helping to prevent overheating.
  • High Reliability: Designed for easy operation and high accuracy.

3. Specifications

Table 1: KWS-DC26 Product Parameters
Parameter Value
Model NumberKWS-DC26
Voltage Measurement RangeDC 8-80V ± 1%+0.5V
Current Measurement Range0-20A/25A/35A/50A ± 1%+0.2A
Power Measurement Range0-4000W ± 1%+2W
Electric Energy Range0-99999Wh
Ampere Hour Range0-9999Ah
Timing Range99 days and 59 hours
Temperature Range-20~99 ℃ ± 2%
Monitor51*30MM Color LCD
Power Failure MemoryYes
Over Pressure IndicationYes
Overcurrent IndicationYes
Overtemperature AlertYes
Zeroing of Electrical EnergyYes
Timekeeping is Zeroed OutYes
Screensaver SettingsYes
Product Size90 * 54 * 23.6mm (3.54 * 2.13 * 0.93 inches)
CertificationCE, RoHS
Table of KWS-DC26 product parameters and dimensions diagram.
Figure 2: Detailed Product Parameters and Dimensions

4. Setup and Connection

The KWS-DC26 supports various plug types to accommodate different applications. Ensure you select the correct current rating (20A, 25A, 35A, or 50A) for your needs.

Image showing various compatible plug types: Anderson 50A, Pin-type 20A, XT60-25A, XT90-35A.
Figure 3: Compatible Plug Types

4.1 Connection Scenarios

Refer to the diagram below for proper connection methods depending on your testing scenario.

Diagram illustrating three connection situations for the KWS-DC26 tester: 1) Tester connected to electric vehicle battery pack alone, displaying voltage. 2) Tester connected to electric vehicle charger alone, displaying voltage. 3) Tester connected to both EV charger and EV battery pack, showing normal testing of voltage and current.
Figure 4: Connection Scenarios for KWS-DC26
  1. Situation 1 (Battery Pack Only): When the tester is connected to the battery pack of an electric vehicle alone, the tester will display the voltage value of the battery pack at that time.
  2. Situation 2 (Charger Only): When the tester is connected to the electric vehicle charger alone, the tester will display the voltage value of the charger at that time.
  3. Situation 3 (Charger and Battery Pack): When the tester is connected to both the EV charger and the EV battery pack, the tester will show normal operation, and begin testing voltage and current.

Important: Always ensure correct polarity when connecting the tester to avoid damage to the device or the connected equipment.

5. Operation

The KWS-DC26 features a user-friendly interface with a color LCD screen and simple controls for monitoring various electrical parameters.

KWS-DC26 display showing voltage, current, power, energy, time, and temperature, highlighting bidirectional measurement, data recording, and timing functions.
Figure 5: Voltage, Current, and Power Meter Display

5.1 Display Interpretation

The color LCD screen provides real-time data:

  • Voltage (V): Displays the current voltage.
  • Current (A): Shows the current flowing through the circuit.
  • Power (W): Indicates the instantaneous power consumption.
  • Energy (Wh): Accumulates the total electrical energy consumed.
  • Ampere-hour (Ah): Accumulates the total charge transferred.
  • Timing: Displays the duration of the measurement.
  • Temperature (°C): Shows the real-time temperature detected by the probe.
  • Directional Arrows: Indicate the direction of current flow for bidirectional measurement.

5.2 Controls

The device typically features buttons for navigation and function control. While specific button functions are not detailed, common operations include:

  • Mode (M) Button: Likely used to cycle through display modes or access settings.
  • Arrow Buttons (Up/Down or Left/Right): Used for navigating menus or adjusting settings.

Consult the on-screen prompts or experiment with the buttons to understand their specific functions for resetting values or changing settings.

6. Applications

The KWS-DC26 is versatile and suitable for a wide range of DC power monitoring applications:

  • Battery performance testing (e.g., lead-acid, ternary lithium, lithium iron phosphate, and other batteries).
  • Solar energy system monitoring.
  • Electric vehicle charging station monitoring.
  • Monitoring outdoor power supplies.
  • Use with various electric vehicle models, including floor sweepers and electric lifts.
Product overview showing compatibility with lead-acid, ternary lithium, lithium iron phosphate, and other batteries.
Figure 6: Battery Compatibility
Examples of applications including outdoor power supplies and electric powered vehicles.
Figure 7: Outdoor Power Supply and Electric Vehicle Applications
Examples of applications including mall sweepers and electric lifts.
Figure 8: Mall Sweeper and Electric Lift Applications

7. Maintenance

  • Keep the device clean and free from dust and moisture.
  • Avoid exposing the device to extreme temperatures or direct sunlight for prolonged periods.
  • Do not attempt to disassemble or repair the device yourself. Refer to qualified personnel for service.
  • Store the device in a dry, cool place when not in use.
  • Regularly check the connectors and cables for any signs of wear or damage.

8. Troubleshooting

The KWS-DC26 is designed with several protective features and indicators to help identify potential issues:

  • No Display: Ensure the device is correctly connected to a power source within the specified voltage range (DC 8-80V). Check all connections for looseness.
  • Over Pressure Indication: If an over-voltage condition is detected, the device will indicate this. Disconnect immediately and check the input voltage.
  • Overcurrent Indication: If the current exceeds the rated capacity (e.g., 20A, 25A, 35A, or 50A depending on model), an overcurrent indication will appear. Reduce the load or use a tester with a higher current rating.
  • Overtemperature Alert: The built-in temperature probe monitors the device's temperature. If an alert appears, disconnect the device and allow it to cool down. Ensure adequate ventilation and avoid operating in high ambient temperatures.
  • Inaccurate Readings: Ensure connections are secure and clean. Verify that the device is operating within its specified measurement ranges.
KWS-DC26 showing real-time temperature monitoring with a thermostat probe to prevent overheating.
Figure 9: Temperature Monitoring Feature

9. User Tips

No specific user tips were available from reviews or Q&A for this product at the time of manual creation. However, general best practices for using DC power meters include:

  • Always double-check your connections before applying power to prevent damage.
  • For long-term monitoring, ensure the device is placed in a well-ventilated area.
  • Utilize the data recording feature to track performance over time, especially for battery health or solar panel output.

10. Warranty and Support

For warranty information and technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

11. Package Contents

  • KWS-DC26 Tester x 1

© 2023 Aideepen. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.