Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the HLTNC Pressure Sensor. This device is designed for accurate pressure measurement in various media including oil, gas, water, and air, offering reliable performance in industrial and commercial applications.
Safety Information
Please read and understand all safety instructions before installing, operating, or maintaining the pressure sensor. Failure to follow these instructions may result in injury or equipment damage.
- Ensure power is disconnected before any installation or maintenance procedures.
- Installation should only be performed by qualified and experienced personnel.
- Verify the compatibility of the sensor's materials with the measured medium and ensure the pressure range is suitable for your application.
- Do not exceed the specified maximum operating pressure or temperature limits of the sensor.
- Protect the sensor from physical impact, excessive vibration, and exposure to harsh or corrosive chemicals.
Product Overview
The HLTNC Pressure Sensor is a robust and accurate device designed for a wide range of pressure measurement applications. It features a durable construction and various output options to suit different control systems.
Key Features
- Sensor Type: Gauge pressure
- Thread Size: M20*1.5 (customizable options available)
- Measurement Range: Available in various ranges, e.g., 0-0.6Mpa, 0-1.0Mpa, 0-1.6Mpa, 0-2.0Mpa, 0-2.5Mpa
- Accuracy: ±0.5% FS
- Output Options: 4-20mA, 0-5V, 0-10V (customizable options available)
- Power Supply: DC24V (for 4-20mA, 0-10V outputs), DC5V (for 0.5-4.5V output)
- Medium Compatibility: Suitable for Oil, Gas, Water, Air
- Process Connection: M20x1.5 external thread (customizable)
- Diaphragm Material: 316LSS
- Process Connection Material: 304SS
- Protection Level: IP65
- Electrical Interface: Hessman connector

Installation
Mounting
The pressure sensor is equipped with an M20x1.5 external thread for direct connection to your process line. Ensure the mounting point is stable, free from excessive vibration, and allows for easy access for future maintenance. The IP65 protection level ensures suitability for various industrial environments, but avoid conditions that exceed its specified operating parameters.
Wiring Diagrams
Correct electrical wiring is essential for the sensor's functionality and accurate signal transmission. Refer to the following diagrams for connecting the sensor to your power supply and receiving instrument.


Typical Application Setup
The HLTNC Pressure Sensor can be seamlessly integrated into various industrial systems. Below is a diagram illustrating its placement within a constant pressure water supply process flow.

Operation
Once the HLTNC Pressure Sensor is correctly installed and wired, it will automatically begin measuring pressure and transmitting the corresponding electrical signal (4-20mA, 0-5V, or 0-10V) to your connected instrument or control system.
Parameter Settings (if applicable)
For models that allow for parameter adjustments or require specific configurations, please adhere to the following guidelines:
- F0-04 Setting: This parameter is typically set to '16' when the sensor's range is 0-1.6Mpa.
- Pressure Gauge Range: If your system uses a pressure gauge with a range of 1.0Mpa, the default parameter output values are generally sufficient.
- F0-19 Setting: For applications requiring a 4-20mA current signal output, this parameter is usually set to '0'.
For any customized settings or if your application requires specific adjustments not covered here, please consult the manufacturer's technical documentation or support.
Maintenance
To ensure the longevity, accuracy, and optimal performance of your HLTNC Pressure Sensor, regular maintenance is recommended:
- Regular Cleaning: Periodically clean the exterior of the sensor, especially the pressure port and process connection area, to prevent accumulation of debris or corrosive substances that could affect readings or cause damage. Use a soft cloth and a mild, non-abrasive cleaning solution.
- Inspect Connections: Routinely check all electrical connections for tightness and signs of wear, corrosion, or damage. Ensure the process connection remains leak-free. Loose connections can lead to intermittent operation or inaccurate measurements.
- Calibration Verification: Depending on the criticality of your application and required accuracy, periodic calibration checks are advisable. Refer to relevant industry standards or your system's specific requirements for recommended calibration intervals.
- Environmental Protection: Ensure the sensor is continuously operated within its specified environmental conditions (temperature, humidity). Protect it from direct exposure to extreme weather or harsh industrial environments unless specifically designed for such conditions.
- Avoid Overpressure: Never subject the sensor to pressures exceeding its maximum rated range. Overpressure can cause irreversible damage to the sensing element.
Troubleshooting
If you encounter any issues with your HLTNC Pressure Sensor, refer to the following common problems and their potential solutions:
No Output or Incorrect Readings
- Check Power Supply: Verify that the sensor is receiving the correct power supply voltage (DC24V or DC5V) and that the supply is stable and within the specified limits.
- Verify Wiring: Carefully re-check all electrical connections against the wiring diagrams provided in the Installation section. Ensure correct polarity, secure terminals, and continuity of cables.
- Inspect Process Connection: Confirm that the sensor is properly installed in the process line and that there are no blockages, leaks, or air pockets at the pressure port.
- Medium Compatibility: Ensure the measured medium is compatible with the sensor's wetted parts (316LSS diaphragm, 304SS process connection). Incompatible media can cause corrosion or damage.
- Sensor Damage: Visually inspect the sensor for any signs of physical damage. If damage is suspected, the sensor may require replacement.
Unstable Output
- Vibration: Check for excessive vibration at the mounting location. If present, consider using vibration dampeners or relocating the sensor.
- Pressure Fluctuations: Rapid or pulsating pressure changes in the process can cause unstable readings. Consider installing a pressure snubber or damper in the system to smooth out fluctuations.
- Electrical Noise: Ensure proper grounding and shielding of signal cables to minimize electromagnetic interference (EMI) or radio frequency interference (RFI).
Sensor Not Responding
- Complete Power Cycle: Disconnect the power supply to the sensor for a few minutes, then reconnect it to perform a hard reset.
- Check for Blockages: Ensure the pressure port is not clogged with debris, sediment, or frozen medium.
If the problem persists after attempting these troubleshooting steps, please contact technical support for further assistance.
Specifications
The following table details the technical specifications of the HLTNC Pressure Sensor:
| Attribute | Value |
|---|---|
| Sensor type | Gauge pressure |
| Thread Size | M20*1.5 or customize |
| Measurement range | 0-0.6Mpa, 0.1Mpa ect. |
| Accuracy | ±0.5% FS |
| Power supply | 4-20mA ,0-5V,0-10V or Customize |
| Medium | Oil, Gas, Water, Air |
| Process connection | M20x1.5 external thread or customize |
| Diaphragm material | 316LSS |
| Process connection material | 304SS |
| Protection level | IP65 |
| Electrical interface | Hessman connector |
| Battery Included | No |
| High-concerned chemical | None |
| Origin | Mainland China |
| Certification | CE |
Application Versatility
The HLTNC Pressure Sensor is suitable for a wide array of applications, from water pressure testing in milk and real estate industries to RO systems in coal mines and process monitoring in silicon industries.


User Tips
To maximize the performance and lifespan of your HLTNC Pressure Sensor, consider the following user tips:
- For optimal performance and ease of maintenance, install the sensor in a location that is easily accessible and allows for clear visual inspection.
- When ordering a customizable sensor, always clearly specify your desired measurement range, output signal type (e.g., 4-20mA, 0-5V), and thread size to ensure you receive the correct product for your application.
- Before powering on, meticulously review all wiring connections against the provided diagrams. Incorrect wiring can lead to sensor malfunction or damage to connected equipment.
- Regularly monitor the sensor's readings and compare them with known good values or other instruments to detect any potential drift or issues early.
Warranty and Support
For technical support, warranty inquiries, or specific customization requests, please contact the manufacturer or your authorized distributor. Ensure you have your product details and any relevant purchase information ready.
A comprehensive user manual in PDF format, containing additional details and diagrams, is available for download: User Manual (PDF)
For customization requests or direct technical assistance, you may also send an email to: hengli0688@163.com