1. Introduction
This manual provides instructions for the installation, operation, and maintenance of the CENTURY AOKE WJZH-M01 Wireless Motor Controller. This device is designed to control DC motors, such as those found in linear actuators, electric push rods, and tractable doors, allowing for forward and reverse movement via remote control. Please read this manual thoroughly before use to ensure proper and safe operation.
2. Safety Information
- Ensure the power supply voltage matches the specified working voltage (DC8-36V) to prevent damage to the device.
- Disconnect power before performing any wiring or maintenance to avoid electrical shock.
- Do not exceed the maximum load of 10A (suggested motor load less than 5A) to prevent overheating and damage.
- Keep the device away from water, moisture, and extreme temperatures.
- Only qualified personnel should perform installation and wiring.
3. Package Contents
Depending on your purchase option, your package may include:
- WJZH-M01 Wireless Motor Controller (Receiver)
- Remote Control(s) (Transmitter)
4. Specifications
| Feature | Specification |
|---|---|
| Model | WJZH-M01 |
| Working Voltage | DC8-36V |
| Quiescent Current | Less than 8mA |
| Working Temperature | -40°C to +80°C |
| Receiver Sensitivity | More than -105dBm |
| Working Frequency | 433MHz |
| Function | Limit & Wire External Button (supports normally open type switches) |
| Max Load | 10A (suggest motor load less than 5A) |
| Size | 68 x 44 x 25mm |
5. Setup Instructions
5.1 Wiring Diagram
Connect the DC power supply and motor to the receiver as shown in the diagram below. If using external limit switches, connect them to SW1 and SW2. The MD soldered dot on the receiver determines the control mode (Momentary or Latched).
- DC-COM / DC+: Power input (DC8-36V).
- SW2 / SW1: Connections for external limit switches (normally open type).
- M2 / M1: Motor connections.
- K2 / K1: Connections for manual control buttons.
5.2 Learning (Pairing) Remote Controls
The working mode (Momentary or Latched) is determined by the learning process.
5.2.1 Momentary Mode Learning
- Press the learning button on the receiver once. The indicator will flash once and remain ON.
- Press the 'Up' button on the transmitter (remote control). The learning indicator will flash 3 times and remain ON.
- Press the 'Down' button on the transmitter. The learning indicator will flash 3 times and then turn OFF. This indicates successful Momentary mode learning.
5.2.2 Latched Mode Learning
- Press the learning button on the receiver twice. The indicator will flash twice and remain ON.
- Press the 'Up' button on the transmitter. The learning indicator will flash 3 times and remain ON.
- Press a 'Stop' button (if available on the remote, or another designated button) on the transmitter. The learning indicator will flash 3 times and remain ON.
- Press the 'Down' button on the transmitter. The learning indicator will flash 3 times and then turn OFF. This indicates successful Latched mode learning.
5.3 Clearing Remote Controls
To clear all paired remote controls from the receiver's memory:
- Press the learning button on the receiver three times.
- The learning indicator will flash 5 times and then turn OFF. This means all transmitter codes in the receiver have been cleared.
6. Operating Instructions
6.1 Momentary Mode (Default Manual Control)
In Momentary mode, the motor operates only while the remote button is pressed. The MD soldered dot on the receiver should NOT be connected for this mode.
- Forward: Press and hold the 'Up' button on the transmitter. The motor will move forward. Release the button to stop the motor.
- Reverse: Press and hold the 'Down' button on the transmitter. The motor will move in reverse. Release the button to stop the motor.
- Manual Control: Press and hold the external K1 button for forward movement. Release to stop. Press and hold the external K2 button for reverse movement. Release to stop.
6.2 Latched Mode
In Latched mode, the motor starts with one press and stops with another. The MD soldered dot on the receiver needs to be connected for this mode.
- Forward: Press the 'Up' button on the transmitter once. The motor will move forward. Press the 'Stop' button (if available) or the 'Up' button again to stop the motor.
- Reverse: Press the 'Down' button on the transmitter once. The motor will move in reverse. Press the 'Stop' button (if available) or the 'Down' button again to stop the motor.
- Manual Control: Press the external K1 button once for forward movement. The motor stops after pressing the external SW1 limit switch. Press the external K2 button once for reverse movement. The motor stops after pressing the external SW2 limit switch.
7. Maintenance
- Keep the receiver and remote controls clean and dry.
- Avoid exposing the devices to direct sunlight or extreme temperatures.
- Regularly check wiring connections for security and integrity.
- Replace remote control batteries as needed.
8. Troubleshooting
- Motor not responding:
- Check power supply connections to the receiver.
- Ensure the remote control batteries are not depleted.
- Verify that the remote control is properly paired with the receiver (refer to Section 5.2).
- Confirm motor wiring is correct.
- Motor only works in one direction:
- This often indicates an issue with the learning process for the reverse command. Re-learn the remote control in the desired mode (Momentary or Latched), ensuring both 'Up' and 'Down' commands are successfully programmed.
- Check the motor wiring for correct polarity and connections.
- Interference with other 433MHz devices:
- The device operates on 433MHz. If you experience interference or if the device doesn't work with other 433MHz remotes, it might be due to different encoding protocols or specific frequency variations. This controller is designed to work with its paired remotes.
- If using multiple sets in close proximity, they should be paired individually to their respective receivers. While the system uses 433MHz, specific encoding prevents cross-interference between different paired sets.
9. User Tips
- Power Supply: Ensure you have a stable DC power supply within the 8-36V range. A reliable power source is crucial for consistent operation.
- Testing: Before final installation, test the controller and motor with a temporary power supply to confirm all functions (forward, reverse, stop) are working as expected.
- Limit Switches: If your application requires precise stopping points, utilize external normally open type limit switches connected to SW1 and SW2 for enhanced control, especially in Latched mode.
10. Warranty and Support
For warranty information or technical support, please refer to the seller's policies or contact the point of purchase. Keep your purchase receipt for any warranty claims.
For additional information, you may refer to the official user manual PDF: WJZH-M01 User Manual (PDF)