OWON XDS2102A

Rate this product if you’ve used it
Contents

OWON XDS2102A Digital Oscilloscope Instruction Manual

Brand: OWON | Model: XDS2102A

1. Introduction

This manual provides essential information for the safe and effective operation of your OWON XDS2102A Digital Oscilloscope. The XDS2102A is a high-performance 2-channel digital oscilloscope featuring a 100MHz bandwidth, 1GS/s sample rate, 20M record length, and a 12-bit high-resolution ADC, all displayed on an 8-inch LCD. Please read this manual thoroughly before use to ensure proper handling and to prevent damage or injury.

OWON XDS2102A Digital Oscilloscope with 8-inch 12-bit high resolution ADC, 20M record length, 55,000 wfms/s refresh rate, 2-channel 100MHz bandwidth, 1GSa/s sample rate.
Figure 1: OWON XDS2102A Digital Oscilloscope Overview

2. Safety Information

Always observe the following safety precautions to prevent electric shock, fire, or personal injury, and to ensure the longevity of your device.

General Safety Guidelines

  • Do not drop the product or subject it to physical shock.
  • Keep the device away from magnetic interference.
  • Ensure the operating environment meets the device's requirements.
  • Operating temperature: -30°C to 55°C (-22°F to 131°F).
  • Operating humidity: 5% to 95%.
  • Do NOT expose the device to strong electromagnetic radiation or dusty environments.
  • Do NOT aim the lens at the sun or any other bright light source.
  • Place the device in a dry and well-ventilated environment.

Power Supply

  • Input voltage: 100V - 240V AC, 50/60Hz, CAT II.
  • Power consumption: Less than 15W.
  • Fuse: 2A, T class, 250V.
  • Ensure the plug is correctly connected to the power socket.
  • DO NOT connect multiple devices to a single power adapter to avoid overheating or fire hazards due to overload.

Battery Information (if applicable)

  • The external rechargeable battery type is 18650.
  • Battery size: 19 mm x 70 mm.
  • Rated voltage: 3.6 VDC.
  • Battery capacity: 3200 mAh.
  • CAUTION: Risk of explosion if the battery is replaced by an incorrect type. Replace only with the same or equivalent type.
  • Batteries of improper size cannot be installed and may cause abnormal shutdown.
  • Purchase batteries recommended by the manufacturer if necessary.
  • Dispose of used batteries according to local regulations.
  • Remove the battery if the device will not be used for a long time.
  • For long-term storage, fully charge the battery every six months to maintain its quality.
  • Ensure battery temperature is between 0°C and 45°C (32°F to 113°F) when charging.
  • Do not dispose of the battery into fire or a hot oven, or mechanically crush or cut it, as this may cause an explosion.
  • Do not leave the battery in extremely high temperature or low air pressure environments, which may result in explosion or leakage of flammable liquid or gas.
  • Ensure no flammable material is within 2m of the charger during charging.
  • Do NOT place the device with battery or the battery alone near heating or fire sources. Avoid direct sunlight.
  • Keep the battery out of reach of children.
  • Do NOT swallow the battery to avoid chemical burns.

3. Package Contents

Carefully unpack the box and ensure all items listed below are present and in good condition. If any item is missing or damaged, please contact your retailer.

Image showing the OWON XDS2102A oscilloscope and its accessories: Power Cord, USB cable, Probes, Probe Adjuster, CD Rom, Quick Guide, and an optional Carry Bag.
Figure 2: Accessories and Packaging
  1. Power Cord
  2. USB Cable
  3. Probes (typically 2 for a 2-channel oscilloscope)
  4. Probe Adjuster
  5. CD Rom (containing software and documentation)
  6. Quick Guide
  7. Optional: Carry Bag
Close-up of the supplied high-quality 100MHz passive probes for the OWON XDS2102A oscilloscope.
Figure 3: Supplied 100MHz Passive Probes

4. Device Appearance and Controls

Familiarize yourself with the layout and controls of your XDS2102A oscilloscope.

Detailed view of the OWON XDS2102A oscilloscope highlighting the multipurpose rotary and push button, and the USB port for data storage and firmware updates.
Figure 4: Key Controls and Ports

Key Components and Controls:

  • 8-inch 800x600 High Resolution LCD: For clear waveform display.
  • Multipurpose Rotary and Push Button: Used for navigation and parameter adjustments within the menu system.
  • USB Host Port: For storing data and firmware updates.
  • USB Device Port: For connecting to a PC.
  • LAN Port: For network connectivity.
  • VGA Port: For external display connection, useful for video expansion and teaching demonstrations.
  • Trig Out (P/F) Port: Trigger output.
  • AUX Port: Auxiliary input/output.

5. Setup

5.1 Powering On/Off

  1. Connect the power cord to the oscilloscope's power input and then to a suitable AC power outlet (100V-240V AC, 50/60Hz).
  2. Press the power button located on the front panel to turn the device on.
  3. To turn off the device, press and hold the power button until the device shuts down.

5.2 Probe Connection

  1. Connect the BNC connector of the probe to the desired channel input (CH1 or CH2) on the oscilloscope.
  2. Attach the ground clip of the probe to the circuit's ground.
  3. Connect the probe tip to the test point on your circuit.
  4. Use the probe adjuster to compensate the probe if necessary for accurate measurements.

6. Operating Instructions

6.1 Basic Waveform Display

  • Adjust the vertical scale (V/div) and horizontal scale (s/div) knobs to fit the waveform on the screen.
  • Use the position knobs to move the waveform vertically and horizontally.
  • The 12-bit high-resolution ADC provides 16 times greater precision and detail compared to 8-bit ADCs, allowing for more accurate measurement of signals, especially small ones.
  • The 55,000 wfms/s waveform refresh rate ensures a responsive and detailed display of dynamic signals.
  • The 20M record length allows for capturing long signal durations with high detail.
Comparison of 12-bit vs 8-bit ADC resolution on an oscilloscope, showing the 12-bit display with significantly more detail and precision for a complex waveform.
Figure 5: 12-bit High Resolution ADC for greater detail
Image illustrating the 55,000 wfms/s high refresh rate and 20M record length features of the oscilloscope, showing how 12-bit resolution helps see small signals.
Figure 6: High Refresh Rate and Record Length

6.2 Trigger and Decoding Functions

The XDS2102A supports advanced trigger types and communication protocol decoding functions.

Diagram showing various advanced trigger types and communication protocol decoding functions supported by the OWON XDS2102A oscilloscope, including Runt, Timeout, Pulse, Video, Windows, SPI, I2C, RS232, CAN, Edge, Slope, and Logic.
Figure 7: Advanced Trigger and Decoding Functions
  • Trigger Types: Edge, Video, Pulse, Slope, Runt, Windows, Timeout, Nth Edge, Logic, I2C, SPI, RS232, and CAN.
  • Bus Decoding: I2C, SPI, RS232, and CAN.
  • Use the dedicated trigger and decoding buttons on the front panel to access and configure these functions.

6.3 Extra Features

  • SCPI Commands: Supports Labview, VB 6, and Visual C++ 6 for remote control and automation.
  • Advanced Functions: Includes calculus and FFT RMS for signal analysis.
  • Waveform Storage: Up to 50 groups of waveform storage.

7. Specifications

FeatureSpecification
ModelXDS2102A
Bandwidth100MHz
Sample Rate1GS/s (8 bits), 500MS/s (12 bits)
Vertical Resolution (A/D)12 bits
Record Length20M
Waveform Refresh Rate55,000 wfms/s
Horizontal Scale (s/div)2ns/div - 1000s/div, step by 1~2~5
Rise Time (at input, typical)≤3.5ns
Channels2 + 1 (external)
Display8" color LCD, 800 x 600 pixels
Input Impedance1MΩ ± 2%, in parallel with 15pF ± 5pF
Channel Isolation50Hz: 100:1, 10MHz: 40:1
Max Input Voltage1MΩ ≤ 300Vrms
DC Accuracyaverage≥16: ±(3% reading + 0.05 div) for △V
Probe Attenuation Factor0.001X - 1000X, step by 1 - 2 - 5
LF Response (AC, -3dB)≥10Hz (at input, AC coupling, -3dB)
Sample Rate / Relay Time Accuracy±1 ppm (Typical, Ta=+25℃)
InterpolationSine of x divided by x
Interval (△T) Accuracy (full bandwidth)Single: ±(1 interval time + 1ppm x reading + 0.6ns); Average> 16: ±(1 interval time + 1ppm x reading + 0.4ns)
Input CouplingDC, AC, and GND
Vertical Sensitivity1mV/div - 10V/div (at input)
Trigger TypeEdge, Video, Pulse, Slope, Runt, Windows, Timeout, Nth Edge, Logic, I2C, SPI, RS232, and CAN
Bus DecodingI2C, SPI, RS232, and CAN
Trigger ModeAuto, Normal, and Single
Vertical Range±2V (1mv/div - 50mv/div), ±20V (100mv/div - 1V/div), ±200V (2V/div - 10V/div)
Line / Field Frequency (video)NTSC, PAL and SECAM standard
Cursor Measurement△V, and △T between cursors, △V and △T between cursors, and auto-cursors
Automatic MeasurementVpp, Vavg, Vrms, Freq, Period, Week RMS, Cursor RMS, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot, Phase, Preshoot, Rise Time, Fall Time,+Width, -Width, +Duty, -Duty, Duty Cycle, Delay A→B ↑, Delay A→B↓, +Pulse Count, -Pulse Count, Rise Edge Count, Fall Edge Count
Waveform Math+, -, ×, ÷, FFT,FFTrms, Intg, Diff, Sqrt, User Defined Function, digital filter (low pass, high pass, band pass, band reject)
Waveform Storage50 waveforms
Lissajou's Figure Bandwidthfull bandwidth
Lissajou's Figure Phase Difference±3 degrees
Communication InterfaceUSB host, USB device, USB port for PictBridge, Trig Out (P/F), LAN, and VGA (optional)
Frequency Counteravailable
Power Supply100V - 240V AC, 50/60Hz, CAT II
Power Consumption<15W
Fuse2A, T class, 250V
Dimension (W x H x D)340 x 177 x 90 mm
Weight2.40 kg

Specifications are subject to change without prior notice.

8. Maintenance

8.1 Cleaning

  • Wipe the device gently with a clean cloth and a small quantity of ethanol, if necessary.
  • Clean the lens with a soft and dry cloth or wiping paper to avoid scratching it.

8.2 Storage

  • If the device will not be used for a long time, remove the battery (if applicable).
  • Store the device in a dry and well-ventilated environment.
  • Keep the device in its original or similar packaging during transport.
  • Retain all packaging materials for future use. In case of a fault, the device should be returned to the factory in its original packaging.

9. Troubleshooting

No specific troubleshooting steps are provided in the available product information. For any operational issues or malfunctions, please refer to the comprehensive user manual (if available) or contact customer support.

Emergency

  • If smoke, odor, or noise arises from the device, immediately turn off the power, unplug the power cable, and contact the service center.

10. User Tips

Based on general oscilloscope usage and product features:

  • Utilize the 12-bit ADC for precise measurements, especially when dealing with small signals that might be missed by lower-resolution oscilloscopes.
  • Take advantage of the 20M record length to capture longer events without losing waveform detail.
  • The high waveform refresh rate (55,000 wfms/s) is beneficial for observing transient events and glitches.
  • Explore the various trigger types and bus decoding functions to efficiently debug complex digital and mixed-signal circuits.
  • Use the USB host port for quick data storage to a USB drive, and the USB device port for PC connectivity for further analysis or remote control.
  • The VGA port can be very useful for educational purposes or presentations, allowing the display to be mirrored on a larger screen.

11. Warranty and Support

For warranty information, technical support, or service, please contact your retailer or the nearest authorized service center. Ensure you retain your proof of purchase.

If the product does not function properly, please contact your dealer or the nearest service center. The manufacturer assumes no responsibility for problems caused by unauthorized repair or maintenance.

The provided PDF user manual (`https://manuals.plus/m/afff0fcd3ef9c6651b284bb40944d93ccf451aa772daf6ff5146821690f37b83`) is for a HIKMICRO Thermal Monocular and is not relevant to this OWON XDS2102A Digital Oscilloscope. Please refer to the documentation provided with your specific OWON product for detailed user guides.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?