1. Introduction
This manual provides detailed instructions for the safe and efficient operation of your Gaqqee WZ10020L Digital Control Power Supply Module. This module is a high-voltage, high-power, large-current step-down converter designed for constant voltage and current applications, including special battery charging and MPPT solar charging. Please read this manual thoroughly before use and keep it for future reference.
For a downloadable PDF version of this manual, please refer to the official product documentation.
2. Product Overview
2.1 Key Features
- Widely applicable for various power supply needs.
- Multiple working modes: DCDC power supply, battery charging, and MPPT solar charging.
- Enhanced heat dissipation with an intelligent fan and reserved 5V interface for additional cooling.
- High conversion efficiency due to synchronous rectification technology.
- Multiple software protection mechanisms with adjustable thresholds (over temperature, over power, over voltage, over current, etc.).
- Automatic shutdown at fixed time and capacity.
- LCD display for input/output voltage, temperature, current, power, capacity, and time.
- Numerical control constant voltage and current regulation with precise and fast step-down output (0-100.00V adjustable).
- Current limit adjustable from 0-20.00A (for output <50V) or 0-10.00A (for output >50V).
- Module can be set to default ON/OFF and save power-off parameters.
- Reserved TTL serial port and input control IO for customization.
2.2 Components
The WZ10020L module consists of a main board and a separate display and setting panel, connected via dedicated cables.

Figure 2.2.1: Product Introduction Diagram showing main board components and display panel connections.
- Main Board: Includes cooling fan, input terminals (IN+ positive, IN- negative), output terminals (OUT+ positive, OUT- negative), special battery charging terminals (BAT+ cathode, BAT- negative pole), and an open/close power system.
- Display and Setting Panel: Features an LCD screen, SW button, U/I button, and a rotary encoder with ON/OFF functionality.
2.3 Dimensions and Weight

Figure 2.3.1: Dimensions of the WZ10020L module and display panel.
- Panel Size: 79mm (L) x 43mm (W) x 25mm (H)
- Motherboard Size: 130mm (L) x 90mm (W) x 40mm (H)
- Mounting Hole Diameter: Φ3mm
- Net Weight (including wire): Approximately 285g
- Line Length (for display connection): 20cm
3. Setup
Before connecting the module, ensure all power sources are disconnected.
- Connect Display Panel: Connect the display panel to the main board using the provided display connections and KEY connections cables. Ensure correct orientation.
- Input Power Connection: Connect your DC input power source to the IN+ (input positive) and IN- (input negative) terminals on the main board. Observe polarity.
- Output Load Connection: Connect your load to the OUT+ (output positive) and OUT- (output negative) terminals. Observe polarity.
- Battery Charging Connection (Optional): If charging a battery, connect the battery to the BAT+ (special battery charging cathode) and BAT- (special battery charging negative pole) terminals. This interface is physically isolated to prevent backflow and reverse connection.
- Cooling Fan: The module includes a cooling fan. Ensure it is not obstructed. An additional 5V interface is reserved for connecting an external fan if further heat dissipation is required.
Note: This product is a step-down module. The output voltage range will always be lower than the input voltage.
4. Operating Instructions
4.1 Button Description

Figure 4.1.1: Description of buttons and rotary encoder functions.
| Interface | Normal Interface | Regulating Voltage & Constant Current | Set Parameters |
|---|---|---|---|
| SW Button | Short press: Downlink switching Current (A), Power (W), Capacity (Ah), Time (h) Long press: LCD upstream switching Input voltage, Output voltage, Temperature | NULL | Short press: Switch parameters to be set Long press: NULL |
| U/I Button | Short press: Enter regulating voltage constant current interface Long press: Enter setting parameters interface | Short press: Switch between adjusting voltage value, constant current value, and exit regulation interface Long press: NULL | Short press: NULL Long press: Exit setting parameter interface, return to normal |
| Rotary Encoder | Left rotation: Output voltage decreases Right rotation: Output voltage increases | Short press: Adjust parameter shift Long press: NULL Left rotation: Corresponding bit of adjustment parameter decreases Right rotation: Corresponding bit of adjustment parameter increases | Short press: Adjust parameter shift Long press: If parameter allows ON/OFF, switch ON/OFF Left rotation: Corresponding bit of adjustment parameter decreases Right rotation: Corresponding bit of adjustment parameter increases |
4.2 Interface Description

Figure 4.2.1: Normal interface displays and setting interface for voltage and current.
The display panel shows various parameters:
- Normal Interface: Displays output voltage (V), input voltage (V), temperature (°C), output current (A), output power (W), output capacity (Ah), and output time (h). 'OUT' indicates output, 'IN' indicates input.
- Interface for Setting Voltage and Constant Current: Allows setting of output voltage and limiting current.
4.3 Usage Method
4.3.1 Toggle Display Parameters

Figure 4.3.1: How to toggle display parameters on the LCD screen.
- Short press SW: In the normal interface, briefly press the SW key to switch the display on the lower line of the screen. The content cycles through current (A), power (W), capacity (Ah), and time (h).
- Long press SW: Long press the SW key to switch the display on the upper line of the screen. The content cycles between input voltage (IN) and output voltage/temperature (OUT).
4.3.2 Set Output Voltage / Charging Voltage Value

Figure 4.3.2: Setting the output voltage value.
- Short press U/I: Briefly press the U/I button in the normal interface to enter the setting voltage constant current interface. A digit of the set output voltage value will flash.
- Adjust Value: Turn the rotary encoder left to decrease or right to increase the value.
- Select Digit: Short press the rotary encoder to select which digit to adjust.
- Exit: After setting, briefly press the U/I button twice to return to the normal interface. The interface will also automatically return to normal after 10 seconds of inactivity.
4.3.3 Set Constant Current Value / Maximum Charging Current

Figure 4.3.3: Setting the constant current (limiting current) value.
- Enter Setting: Briefly press the U/I button in the normal interface to enter the setting voltage constant current interface.
- Switch to Current Setting: Briefly press the U/I button again to switch to the setting of constant current value. A digit of the constant current value will flash.
- Adjust Value: Turn the rotary encoder left to decrease or right to increase the value.
- Select Digit: Short press the rotary encoder to select which digit to adjust.
- Exit: After setting, briefly press the U/I key to exit the setting voltage constant current interface and return to the normal interface. The interface will also automatically return to normal after 10 seconds of inactivity.
4.3.4 Set Default ON/OFF State at Power-On

Figure 4.3.4: Setting the module's default ON/OFF state when powered on.
- Enter Parameter Setting: In the normal interface, long press the U/I key to enter the parameter setting interface. You will see