1. Foreword
Thank you for purchasing this instrument! This user's manual outlines the working principle, precautions, operation, and maintenance of the instrument. To ensure proper use and prevent potential harm or damage, please read this manual carefully before operation.
The manufacturer is responsible for the safety and reliability of the instrument under the following conditions:
- Installation, reorganization, modification, and maintenance are performed by professionals designated or authorized by the company.
- Electrical equipment connected to the instrument meets the technical parameters specified in this manual.
- Operation is conducted according to this user manual.
This instrument is designed for general human body shaping. Improper use, or use for functions other than those specified, may lead to malfunction, endanger human health, or cause damage. The user assumes all consequences for non-compliance with the manual's instructions.
The manufacturer does not provide guarantees beyond applicability and specific applicability. The company is not responsible for errors in this manual or accidents arising from its actual use. This manual contains proprietary materials protected by patent law; no part may be reproduced or modified without written consent. Contents are subject to change without notice.
Manual version number: V1.0
2. Instrument Introduction and Principles
This is a two-in-one body shaping instrument, comprising a main machine, an EMS handle, and an inner ball roller handle.
2.1. EMS Handle Principle (HI-EMT)
The EMS handle utilizes HI-EMT (High Energy Focused Electromagnetic Waves) technology. It induces continuous muscle expansion and contraction, providing extreme training that deeply remodels muscle internal structure. This leads to the growth of myofibrils (muscle enlargement) and the generation of new protein chains and muscle fibers (muscle hyperplasia), increasing muscle density and volume.
The intense muscle contractions (100% extreme) triggered by HI-EMT technology can cause significant fat breakdown. Fatty acids are decomposed and released from triglycerides, accumulating in adipocytes. High levels of fatty acids cause fat cells to die and be naturally excreted by the body within weeks.
2.2. Inner Ball Roller Handle Principle
The inner ball roller handle employs a non-invasive method of mechanical compression micro-vibration combined with infrared treatment. The mechanical compression micro-vibration involves a ball rotating 360° along its axis. This rotation and rolling generate compression micro-vibration, creating a "pulsating compression" effect. This effect provides continuous push-pull, kneading, and skin tightening without squeezing or damaging the skin.
Infrared therapy releases infrared rays, promoting cell metabolism, enhancing oxygen-blood combination, reducing cellulite, and alleviating muscle stiffness and soreness. It also promotes cell activity and body reshaping.
2.3. Five Synergies of Inner Ball Roller Handle
The inner ball roller handle's design allows for gradual compression and lifting movements, influencing vascular dynamics by balancing hydrostatic and inflation pressures. This helps in the re-entry of liquid and catabolites into the venous side, preventing water stagnation and edema in tissue. This mechanism balances static vein pressure, promotes internal metabolism, and facilitates hemodynamic exchange.
Visual thermal imaging confirms that the thermal effect promotes blood circulation, cell metabolism, fat decomposition, cellulite reduction, and muscle fatigue relief.
2.4. Drainage Effect
Edema results from an imbalance in body fluid production and excretion, leading to fluid retention in interstitial spaces. The inner ball roller handle, through repeated pushing and kneading of edematous areas, helps move stagnant body fluid into circulation, aiding in the removal of toxic substances.
2.5. Adjust Muscles and Maintain Internal Balance
The mechanical rotation, slight pressing, and kneading action of the inner ball roller handle, combined with mechanical compression vibration therapy, promotes deep muscle relaxation and stretching. This reduces muscle fatigue and pain more effectively than manual kneading. It also stimulates muscle relaxation, improves blood circulation, enhances blood oxygen binding, and removes toxins.
3. Characteristics of Inner Ball Roller Handle
- Unique 360° intelligent rotating drum handle for continuous, safe, and stable operation.
- LED display on the handle shows the speed.
- The roller handle includes a key for controlling start or pause.
- Flexible and smooth steel ball design ensures effortless, gentle rolling without stinging, providing even pushing, massage, and lifting for optimal results.
- No need for the user to apply hard pressure; operation is simple and safe.
4. Application Positions
The MYoslim Body Sculpting Machine can be used on multiple parts of the body for targeted treatments:
- Waist
- Neck
- Abdomen
- Foot
- Buttocks
- Arm
- Thigh
- Calf
5. Setup
5.1. Appearance of the Instrument
Familiarize yourself with the components of the MYoslim Body Sculpting Machine:
Front Components: Big wheel, Small wheel, EMS handle, Touch screen, Host machine, On/OFF Button.
Back Components: Port of roller handle, Switch, Handle hanger, Power plug, Port of EMS handle.
Handle Display: The EMS and roller handles are designed for ergonomic use.
Note: All handles must be operated by professional operators.
6. Operating Instructions
6.1. Initial Setup and Power On
- Connect the machine power supply.
- Turn on the rear switch of the machine.
- Turn on the front switch of the machine.
- The machine will display the MYoslim logo and then proceed to the function selection screen.
6.2. Interface Operation Flow
The instrument has two main functions: EMS and WHEELS (roller massage).
6.2.1. EMS Function Selection
- From the function selection screen, select "EMS".
- You can choose between magnetic slimming mode 1 (Pattern 1) or mode 2 (Pattern 2).
- Pattern 1: Allows adjustment of time (1-60 min) and energy (0-100%).
- Pattern 2: Allows adjustment of time (1-60 min), energy (0-100%), and frequency (10-200Hz).
- To start/pause treatment, press the play/pause button.
- To stop treatment, press the stop button.
- To return to the function selection interface, press the "Return" button.
Note: Before operation, take out the EMS handle from its hanger and fix it to the desired operating position on the customer using a strap. During EMS operation, you can pause and adjust energy and time again.
6.2.2. WHEELS Function Selection (Roller Massage)
- From the function selection screen, select "WHEELS".
- You can choose between "Big wheel" or "Small wheel" modes.
- For both modes, you can adjust time (1-60 min), energy (RF, 0-50), rotating speed (0-10), and rotation direction (FWD: clockwise / REV: counterclockwise).
- To start/pause treatment, press the play/pause button.
- To stop treatment, press the stop button.
- To return to the function selection interface, press the "Return" button.
Note: When the handle of the inner ball roller is pressed to contact the skin, the blue light will turn red.
7. Precautions and Contraindications
7.1. Precautions Before Use
- Do not use the instrument when feeling full; use at least one hour after meals.
- Remove any metal jewelry before using the instrument.
- Before starting operation, touch the EMS handle vertically to the treatment area, then turn on the main switch to adjust the intensity.
- Always start with the lowest intensity level, then gradually increase according to the user's skin tolerance.
- Do not eat or drink during operation; try to eat one hour after operation.
7.2. Contraindications
Do not use this instrument on individuals with:
- Large wounds or ulcers on their skin.
- Heart disease (especially arrhythmia) or pacemakers.
- Cancer.
- Infectious diseases.
- Pregnancy, lactation, or menstruation.
- Major surgical history or diabetes.
- Any metal implants in their bodies.
- Cerebrovascular disease (stroke).
7.3. Precautions During and After Use
- Replenish water adequately after use.
- Avoid overeating; maintain a balanced diet and sufficient sleep.
- Strengthen moisturizing and sun protection after use.
- Avoid eating spicy food.
- Avoid soaking in hot springs and saunas for three days after use.
8. Specifications
8.1. Main Machine Technical Parameters
| Parameter | Value |
|---|---|
| Input power | AC 110V-220V 50/60Hz |
| Screen size | 10.4 inches |
| Screen type | Resistance screen |
| Screen resolution | 1024*768 |
| Equipment size | 52x32x43cm |
| Net weight of equipment | 16.6kg |
| Packing size | 59x50x52cm |
| Packing weight | 38kg |
| Fuse | 500V 3A Φ6×30 |
8.2. EMS Handle Parameters
| Parameter | Value |
|---|---|
| Input maximum power | 1500 VA |
| Frequency | 10-200Hz |
| Magnetic flux density | 5T |
8.3. Roller Handle Parameters
| Parameter | Value |
|---|---|
| Input maximum power | 200 VA |
| Frequency | 448KHz |
| Small handle speed | 400rpm |
| Large handle speed | 400rpm |
9. Maintenance
9.1. Daily Inspection
- Check instruments and components regularly.
- Regularly check whether the connection between the power socket and the grounding wire is reliable.
9.2. Cleaning
- Clean the instrument regularly to ensure sanitary conditions and normal operation.
- Do not clean internal circuits.
- Before cleaning, turn off the power and wipe the equipment shell with a wet cloth, soapy water, or neutral detergent.
9.3. Replacing the Fuse
- When replacing the fuse, turn off the power supply and unplug the machine to prevent electric shock.
10. Troubleshooting
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working | Power plug not inserted, power switch off, or power fuse failure. | Check power connection. Turn on power switch. Replace the fuse. |
| Handle not working | Handle is loose. | Reposition the handle securely. |
11. Storage and Transportation
11.1. Storage
The instrument should be stored in its original packing box, in a well-ventilated room, with ambient temperatures between -10°C and 40°C, and relative humidity not exceeding 93%. Avoid placing it in harmful gases, flammable, explosive, or corrosive environments.
11.2. Transportation
The instrument, in its packaging, is suitable for road, railway, air, and water transportation. During loading, unloading, and transit, prevent serious vibration and protect from moisture. Do not mix with flammable or corrosive substances. Specific requirements are detailed in the order contract.
12. Warranty and Support
12.1. Warranty Terms
- The mainframe can be replaced within 7 days of purchase (with receipt).
- The mainframe is guaranteed for one year from the date of receipt (excluding fragile parts and other non-warranty parts or after warranty expiration).
- Maintenance and updates are available, with appropriate fees charged.
- If the instrument is damaged and needs repair, the company covers freight within six months of receipt.
- For periods between six months and one year, freight costs are split equally between the buyer and the company.
- After one year, the buyer bears all freight costs.
12.2. Exclusions from Free Warranty Service
Free warranty service is not provided for failures caused by personal reasons, including:
- Faults caused by unauthorized disassembly and modification of the product.
- Failure caused by accidental falls.
- Failure caused by lack of reasonable maintenance.
- Failure to follow the correct instructions in this manual.
For questions, services, or information, please contact the manufacturer directly.
12.3. Product Lifespan
- The warranty period for the instrument is 1 year (note: non-human damage).
- The warranty period for accessories is 3 months (note: non-human damage).
- Continued use of the instrument after its validity period must be approved by an engineer who regularly tests its performance.
- Abandoned instruments and accessories that have exceeded their service life must be disposed of according to local laws and regulations.
13. Packing List
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | EMS Handle | 2 | ![]() |
| Roller Handle | Big*1, Small*1 | ![]() |
|
| 3 | Bandage | (100*7cm)*2 | |
| 4 | Power cable | 1 | |
| 5 | Abdominal Muscle Piece and Connecting Line | 1 | |
| 6 | Electronic manual | 1 copy |
14. User Tips
- Consistency is Key: For optimal body contouring results, consistent use over several sessions is recommended. Clients often report gradual improvements.
- Easy to Use: The machine features a simple operation interface. Video tutorials are available from the seller to help new users get started quickly.
- Painless Treatment: Users generally find the treatments painless and comfortable.
- Visible Results: Many users experience noticeable results, such as firmer thighs and improved body tone, after just a few sessions.
- Deep Muscle Activation: The advanced EMS technology provides deep muscle activation, contributing to effective body shaping.