Daxtromn AGH-10.2KW-PLUS

Contents

Daxtromn 10.2KW 48V Hybrid Solar Inverter User Manual

Model: AGH-10.2KW-PLUS

1. Introduction

This manual describes the assembly, installation, operation, and troubleshooting of the Daxtromn 10.2KW 48V Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.

This multi-function inverter/charger combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. Its comprehensive LCD display offers user-configurable and easy-to-access button operation for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage for various applications.

1.1 Key Features

  • Pure sine wave solar inverter (on/off Grid)
  • Output power factor 1.0
  • WIFI available for iOS and Android (optional module)
  • Inverter running without battery
  • One-key restoration to factory settings
  • Built-in Lithium battery automatic activation
  • Built-in 160A MPPT solar charger
  • High PV input voltage range (90~450VDC)
  • Built-in anti-dust kit for harsh environments
  • Smart battery charge design to optimize battery life
  • Touch button interface
  • Dual output (2 AC Output function)

1.2 Dual AC Output Function

When there is no Main/AC IN/GRID INPUT, and the battery voltage is lower than the set voltage, the main AC output will cut off automatically. In this scenario, the battery or PV will only offer power for the second AC output.

WARNING: DO NOT CONNECT THE SECOND OUTPUT TO THE GRID, IT WILL DAMAGE YOUR INVERTER.

1.3 Battery Management System (BMS) Compatibility

If your battery has a BMS, connecting it to the inverter's BMS port allows the inverter and battery to communicate. This enables automatic adjustment of charging voltage, cut-off voltage, and other parameters based on the battery's condition. This communication enhances battery life and safety.

IMPORTANT: The inverter and battery must both have BMS functions to communicate with each other.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with a battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow the required specifications to select the appropriate cable size. It is very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
  9. Please strictly follow the installation procedure when disconnecting AC or DC terminals. Refer to the INSTALLATION section for details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
  13. WARNING!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.

3. Product Overview

The Daxtromn 10.2KW 48V Hybrid Solar Inverter is designed for efficient power management in solar energy systems. Below is an overview of its components and a typical system architecture.

3.1 Basic System Architecture

The inverter integrates solar power, utility, and generator inputs with external battery packs to power home appliances. Consult with your system integrator for other possible system architectures depending on your requirements. This inverter can power all kinds of appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.

Connection Diagram of Daxtromn Hybrid Solar Inverter
Figure 1: Connection Diagram. Illustrates how solar power, generator/utility, external battery packs, and home appliances connect to the hybrid inverter.

3.2 Product Components

The inverter features an intuitive front panel with an LCD display, indicators, and touch function buttons, along with various input/output ports on the side and bottom.

Daxtromn Hybrid Solar Inverter Product Overview with numbered components
Figure 2: Product Overview. Detailed view of the inverter's front panel and ports.
  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Touch Function buttons
  6. Power on/off switch
  7. AC input
  8. Main output
  9. Second output
  10. PV1 and PV2 input
  11. WIFI communication/RS-232 port
  12. Battery communication/RS-485 port
  13. Battery input
  14. Anti dust kit
Multiple views of the Daxtromn Hybrid Solar Inverter
Figure 3: Product Display. Various angles of the inverter, showcasing its physical design and port layout.

4. Setup

4.1 Unpacking and Inspection

Before installation, please inspect the unit. Ensure that nothing inside the package is damaged. You should have received the following items:

  • Inverter unit x 1
  • User manual x 1
  • Ring terminal x 1
  • Mc4 terminal head x 2

4.2 Preparation and Mounting

Before connecting any lines, remove the screws under the machine and the bottom cover plate.

IMPORTANT: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Consider the following points when selecting an installation location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the sides and approximately 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C for optimal operation.
  • The recommended installation position is to adhere it vertically to a wall.
  • Ensure enough space around the machine for adequate heat dissipation and room to remove wires.

Install the unit by screwing two M4 or M5 screws.

4.3 Battery Connection

CAUTION: For safety and regulatory compliance, it is recommended to install a separate DC over-current protector or disconnect device between the battery and inverter. While a disconnect device may not be required in all applications, over-current protection is always necessary. Refer to the table below for typical amperage and required fuse or breaker size.

WARNING! All wiring must be performed by qualified personnel.

WARNING! It is very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce the risk of injury, use the proper recommended cable as below:

ModelWire SizeCable (mm²)Torque value (max)
8.2KW/10.2KW1 x 2AWG252 Nm

Follow these steps for battery connection:

  1. Remove 18 mm of insulation sleeve for positive and negative conductors.
  2. It is recommended to use bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram below.
  4. Insert the battery wires flatly into the inverter's battery connectors and ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure polarity is correct at both the battery and the inverter/charger, and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
Battery Connection Diagram
Figure 4: Battery Connection Diagram. Shows how multiple 12V batteries are connected in series to the inverter.

WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.

CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).

4.4 AC Input/Output Connection

CAUTION!! Before connecting to an AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is fully protected from overcurrent. The recommended AC breaker for 8.2KW/10.2KW is 63A.

CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.

WARNING! All wiring must be performed by qualified personnel.

WARNING! It is very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce the risk of injury, use the proper recommended cable size as below:

ModelGaugeCable (mm²)Torque Value
8.2KW/10.2KW10 AWG61.2 Nm

Follow these steps for AC input/output connection:

  1. Before making AC input/output connections, ensure the DC protector or disconnector is open.
  2. Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3 mm.
  3. Insert AC input wires according to the polarities indicated on the terminal block and tighten the terminal screws. Connect the PE protective conductor (yellow-green) first, then L (brown or black), and N (blue).

WARNING: Ensure the AC power source is disconnected before attempting to hardwire it to the unit.

  1. Then, insert AC output wires according to the polarities indicated on the terminal block and tighten the terminal screws: L (brown or black), N (blue).
  2. Make sure all wires are securely connected.

CAUTION: Appliances such as air conditioners require 2-3 minutes to restart. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function. Otherwise, the inverter may trigger an overload fault and cut off output, but internal damage to the air conditioner may still occur.

4.5 PV Connection

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING! It is very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce the risk of injury, use the proper recommended cable size as below:

ModelWire SizeCable (mm²)Torque value (max)
8.2KW/10.2KW1 x 10AWG61.2 Nm

PV Module Selection

When selecting PV modules, consider these parameters:

  • Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter (500Vdc).
  • Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage (90Vdc).
INVERTER MODEL8.2KW/10.2KW
Max. PV Array Open Circuit Voltage500Vdc
PV Array MPPT Voltage Range90Vdc~450Vdc
PV Connection Diagram for Solar Inverter
Figure 5: PV Connection Diagram. Shows a typical solar panel, inverter, battery, and AC output setup for home appliances.

PV Module Wire Connection

  1. Check the input voltage of PV array modules. The acceptable input voltage of the inverter is 120VDC - 500VDC. Ensure the maximum current load of each PV input connector is 10A.

CAUTION: Exceeding the maximum input voltage can destroy the unit!! Check the system before wire connection.

  1. Disconnect the DC circuit breaker.
  2. Assemble provided PV connectors with PV modules. Strip 8 mm of cable insulation, being careful not to nick conductors. Insert stripped cable into female/male terminals and crimp. Insert assembled cable into female/male connector housing. Use a spanner to screw the pressure dome tightly.
  3. Check the correct polarity of the connection cable from PV modules and PV input connectors. Connect positive pole (+) of the connection cable to the positive pole (+) of the PV Input connector. Connect negative pole (-) of the connection cable to the negative pole (-) of the PV input connector.

4.6 Final Assembly

After connecting all wirings, put the bottom cover back by screwing the two screws.

4.7 Communication Connection

Wi-Fi Cloud Communication (Option)

Use the supplied communication cable to connect to the inverter and Wi-Fi module. Download the APP from the APP store and refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown via the mobile phone APP or computer webpage.

GPRS Cloud Communication (Option)

Use the supplied communication cable to connect to the inverter and GPRS module, then apply external power to the GPRS module. Download the APP from the APP store and refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be shown via the mobile phone APP or computer webpage.

Battery Communication

Communication between the battery and the inverter can be realized through the battery communication interface, allowing the inverter and lithium battery to exchange information (Baud rate: 9600).

Lithium Battery and Inverter Connection

Use power cables and communication cables for lithium batteries and inverters to connect. Note the correct installation of lithium battery and inverter positive and negative positions. The RJ45 connector of the communication cable connects to the BMS port of the inverter, and the other RJ45 connector connects to the RS485 port of the lithium battery. Before connecting, ensure both the lithium battery and inverter are turned off. It is recommended to install a circuit breaker for the power cables of the lithium battery and the inverter battery interface to prevent sparks.

Lithium Battery Communication Cable Interface
Figure 6: Lithium Battery Communication Cable Interface. Shows RJ45 connections to BMS and RS485 ports.

5. Operation

5.1 Power ON/OFF

Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the button of the case) to turn on the unit.

5.2 Operation and Display Panel

The front panel of the inverter includes three indicators, four function keys, and an LCD display, showing operating status and input/output power information.

Inverter Display Panel and Function Keys
Figure 7: Inverter Display Panel and Function Keys. Details the LCD display, indicators, and touch buttons.

LED Indicator

IndicatorColorStateMessage
INV/ACGreenSolid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.

Function Keys

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

5.3 LCD Display Icons

The LCD display provides various information about the inverter's status and operation.

Input Source Information

  • AC Input Icon: Indicates the AC input.
  • PV Input Icon: Indicates the PV input.
  • Numeric Display: Shows input voltage, input frequency, PV voltage, charger current (for 10.2KW models), charger power, and battery voltage.

Configuration Program and Fault Information

  • Setting Programs Icon: Indicates the setting programs.
  • Warning/Fault Codes Icon: Indicates warning and fault codes.
  • Warning: Flashing with warning code.
  • Fault: Lighting with fault code.

Output Information

  • Numeric Display: Shows output voltage, output frequency, load percent, load in VA, load in Watt, and discharging current.

Load Information

  • Overload Icon: Indicates overload.

Mode Operation Information

  • Mains Connection Icon: Indicates unit connects to the mains.
  • PV Panel Connection Icon: Indicates unit connects to the PV panel.
  • AC Bypass Icon: Indicates load is supplied by utility power.
  • Utility Charger Circuit Icon: Indicates the utility charger circuit is working.
  • DC/AC Inverter Circuit Icon: Indicates the DC/AC inverter circuit is working.

Mute Operation

  • Mute Icon: Indicates unit alarm is disabled.

5.4 LCD Setting

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the UP or DOWN buttons to select setting programs, then press ENTER to confirm or ESC to exit.

Key Settings (Refer to manual pages 20-27 for full list)

  • Program 00: Exit setting mode (00 GOE for one-button restore, 00 GOK to exit)
  • Program 01: Output source priority (Utility first, Solar first, SBU priority, MKS priority)
  • Program 02: Maximum charging current (Configurable from 10A to 160A)
  • Program 03: AC input voltage range (Appliances (90-280VAC) or UPS (170-280VAC))
  • Program 05: Battery type (AGM, Flooded, User-Defined, LIB-485)
  • Program 12: Setting voltage point back to utility source (When SBU priority or Solar first is selected, configurable from 42V to 51V)
  • Program 13: Setting voltage point back to battery mode (When SBU priority or LIB-485 is selected, configurable from 48.0V to 58.0V)
  • Program 26: Bulk charging voltage (C.V voltage) (Configurable from 48.0V to 61.0V for 8.2KW/10.2KW model)
  • Program 29: Low DC cut-off voltage (Configurable from 40.0V to 48.0V for 8.2KW/10.2KW model)
  • Program 30: Battery equalization (Enable/Disable)
  • Program 43: Lithium battery protocol (PYLON, PACE)
Setting Off-Grid or Hybrid Mode on LCD
Figure 8: Setting Off-Grid or Hybrid Mode. LCD options for 'Off grid' (37 OFF) and 'Hybrid' (37 HYd).
Output Source Priority Settings on LCD
Figure 9: Output Source Priority Settings. LCD options for 'Utility first' (01 USb), 'Solar first' (01 SUb), 'SBU priority' (01 SBU), and 'MKS priority' (01 ntS).

5.5 Operating Mode Description

The inverter supports various operating modes, including Standby, Line, Grid-Tie, and Battery modes. The LCD display will show different information depending on the current state and power flow.

Various Working Modes of Hybrid Solar Inverter
Figure 10: Various Working Modes. Illustrates power flow with and without battery connected, showing solar, generator, utility, and home appliance interactions.

5.6 Battery Equalization

The equalization function helps reverse the buildup of negative chemical effects like stratification and removes sulfate crystals from battery plates, optimizing battery performance and lifespan. This function can be enabled and configured via LCD settings (Program 30, 35, 36).

Mains and Lithium Battery Activation Function

  1. After 90 seconds of mains power connection, the inverter connects to the mains and starts working.
  2. If the inverter is in lithium battery mode (Program 05 is LIP or LIL), and the mains are connected but the battery is not, the mains activation function is automatically enabled.

6. Maintenance

6.1 Clearance and Maintenance for Anti-Dust Kit

Every inverter comes with a factory-installed anti-dust kit. The inverter automatically detects this kit and uses an internal thermal sensor to adjust the internal temperature. This kit also prevents dust from entering the inverter, increasing product reliability in harsh environments.

Maintenance Steps

  1. Loosen the screw in a counterclockwise direction on the top of the inverter.
  2. Remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case. After cleaning, re-assemble the dust-kit back to the inverter.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

7. Troubleshooting

7.1 Fault Reference Code

The inverter's LCD display will show fault codes if an error occurs. Refer to the table below for common fault codes and their explanations.

Fault CodeFault Event
01Fan is locked when inverter is off.
02Over temperature
03Battery voltage is too high
04Battery voltage is too low
05Output short circuited or over temperature is detected by internal converter components.
06Output voltage is too high.
07Overload time out
08Bus voltage is too high
09Bus soft start failed
51Over current or surge
52Bus voltage is too low
53Inverter soft start failed
55Over DC voltage in AC output
57Current sensor failed
58Output voltage is too low
59PV voltage is over limitation

7.2 Battery Fault Codes (Lithium Battery Mode)

Fault CodeFault EventFault Condition
02The battery temperature is too high ProcedureLithium battery charging battery temperature ≥65°C; The discharge temperature of the lithium battery is higher than 70°C.
03The battery voltage is too high ProcedureLithium battery maximum single cell voltage >3.65V; Total voltage of lithium battery >54.6V (48V lithium battery).
04The battery voltage is too low ProcedureMinimum voltage of a lithium battery cell <2.71V; Lithium battery total voltage <40.4V (48V lithium battery).

7.3 Warning Indicator

The inverter provides audible alarms and icon flashes for various warning conditions.

Warning CodeWarning EventAudible Alarm
01Fan is locked when inverter is on.Beep three times every second
03Battery is over-chargedBeep once every second
04Low batteryBeep once every second
07OverloadBeep once every 0.5 second
10Output power deratingBeep twice every 3 seconds
15PV energy is low.Beep twice every 3 seconds
E9Battery equalizationNone
bPBattery is not connectedNone

7.4 Battery Warning Codes (Lithium Battery Mode)

Warning CodeWarning EventWarning Condition
04The battery voltage is too lowMinimum voltage of a lithium battery cell <2.85V; Lithium battery total voltage <42V (48V lithium battery).
05The battery voltage is too highLithium battery maximum single cell voltage >3.55V; Total voltage of lithium battery >54V (48V lithium battery).
06The battery is low warningRemaining battery capacity ≤10%

8. Specifications

Detailed technical specifications for the Daxtromn 10.2KW 48V Hybrid Solar Inverter are provided below.

Inverter Charger Specifications Label
Figure 11: Inverter Charger Specifications Label. Provides detailed electrical and output characteristics.

8.1 General Specifications

AttributeSpecification
Model NumberAGH-10.2KW-PLUS
Size (D*W*H)500*390*136mm
Weight16.5 kg
Output TypeDUAL
Output Frequency50/60 HZ Auto sensor
Is Smart DeviceNo
OriginMainland China
CertificationCE
Phase1-Phase
Operating Temperature Range-10°C to 50°C
Storage Temperature-15°C to 60°C
Humidity5% to 95% Relative Humidity (Non-condensing)

8.2 Line Mode Specifications

INVERTER MODEL8.2KW10.2KW
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

8.3 Inverter Mode Specifications

INVERTER MODEL8.2KW10.2KW
Rated Output Power8.2KW10.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50Hz
Peak Efficiency93%
Overload Protection3s@≥150% load; 5s@101%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage48Vdc
Cold Start Voltage46.0Vdc
Low DC Warning Voltage (@ load < 50%)44.0Vdc
Low DC Warning Voltage (@ load ≥ 50%)42.0Vdc
Low DC Warning Return Voltage (@ load < 50%)45.0Vdc
Low DC Warning Return Voltage (@ load ≥ 50%)44.0Vdc
Low DC Cut-off Voltage (@ load < 50%)41.0Vdc
Low DC Cut-off Voltage (@ load ≥ 50%)40.0Vdc
High DC Recovery Voltage62Vdc
High DC Cut-off Voltage63Vdc
No Load Power Consumption70W75W

8.4 Two Load Output Power

INVERTER MODEL8.2KW10.2KW
Full Load8200W10200W
Maximum Main Load8200W10200W
Second Load Range1640W~5740W2040W~7140W
Main Load Cut Off Voltage52VDC
Main Load Return Voltage54VDC

8.5 Charge Mode Specifications

Utility Charging Mode8.2KW10.2KW
Charging Algorithm3-Step
AC Charging Current (Max)140Amp
Bulk Charging Voltage (Flooded Battery)58.4V
Bulk Charging Voltage (AGM / Gel Battery)56.4V
Floating Charging Voltage54Vdc
MPPT Solar Charging Mode8.2KW10.2KW
Max. PV Array Power (PV1 Channel)5400W
Max. PV Array Power (PV2 Channel)5400W
IMax.PV (PV1 Channel)18A
IMax.PV (PV2 Channel)18A
Nominal PV Voltage360Vdc
PV Array MPPT Voltage Range90Vdc~450Vdc
Max. PV Array Open Circuit Voltage500Vdc
Max Charging Current (AC charger plus solar charger)160Amp

8.6 Grid-Tie Operation

INVERTER MODEL8.2KW10.2KW
Nominal Output Voltage220/230/240 VAC
Feed-in Grid Voltage Range195~253VAC
Feed-in Grid Frequency Range50±1Hz/60±1Hz
Nominal Output Current35.6A44.3A
Power Factor Range>0.99
Maximum Conversion Efficiency (DC/AC)98%

8.7 Approximate Back-up Time Table

ModelLoad (W)Backup Time @ 48Vdc 100Ah (min)Backup Time @ 48Vdc 200Ah (min)
8.2KW/10.2KW5006131288
1000268613
1500158402
2000111271
250090215
320076182
350065141
400050112
450044100
50004090
62003680
72003270
82002860
92002450
102002040

Note: Backup time depends on the quality, age, and type of battery. Specifications of batteries may vary depending on different manufacturers.

9. User Tips

  • Cable Sizing: Always ensure the correct cross-section for battery and AC cables as specified in the manual to prevent injury and ensure efficient operation. For battery connections, 1 x 2AWG (25mm²) is recommended, and for AC input, 10 AWG (6mm²).
  • PV Input Voltage: When operating without an external battery, the solar panel voltage must be above 120VDC for the inverter to function normally. With an external battery, 90VDC is sufficient.
  • BMS Communication: If your battery has a BMS, utilize the inverter's BMS communication feature (Program 05 and 43 settings) for optimized charging and enhanced battery lifespan.
  • Anti-Dust Kit Maintenance: Regularly clean the anti-dust kit (monthly) to maintain optimal performance and extend the inverter's lifespan, especially in harsh environments.

10. Frequently Asked Questions (FAQ)

Q: Can I connect two strings of solar panels of different specifications?
A: Yes, the inverter supports connecting two strings of solar panels with different specifications.
Q: Does this inverter support parallel or series connection with other inverters?
A: No, this inverter does not support parallel or series connection with other units.
Q: What BMS protocols are supported by this inverter?
A: The inverter supports PACE and PYLON BMS protocols for communication with compatible lithium batteries.
Q: Does this inverter feed power back to the grid?
A: Yes, it is an on/off-grid solar hybrid inverter, meaning it can feed power to the grid.
Q: Does the inverter have a WiFi module?
A: Yes, a WiFi module is available for this inverter, allowing monitoring via iOS and Android apps.

11. Warranty and Support

The Daxtromn 10.2KW 48V Hybrid Solar Inverter comes with a 1-year warranty.

For technical support, service, or repair, please contact your local dealer or an authorized service center. Do not attempt to service the device yourself unless you are a qualified service person, as incorrect re-assembly can lead to electric shock or fire.