Daxtromn GGH-6.5KVA Hybrid Solar Inverter User Manual

Model: GGH-6.5KVA (SC HF 5500-48)

1. Introduction

This manual describes the assembly, installation, operation, and troubleshooting of the Daxtromn GGH-6.5KVA Hybrid Solar Inverter. Please read this manual carefully before installation and operation, and keep it for future reference.

1.1 Product Overview

The Daxtromn GGH-6.5KVA is a multi-function inverter/charger, combining the capabilities of an inverter, an MPPT solar charger, and a battery charger. It is designed to provide uninterruptible power support in a portable size. The comprehensive LCD display and user-configurable buttons allow for easy adjustment of settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges for various applications.

This inverter can power a wide range of home and office appliances, including motor-type loads like tube lights, fans, refrigerators, and air conditioners.

Daxtromn GGH-6.5KVA Hybrid Solar Inverter with key specifications
Figure 1: Daxtromn GGH-6.5KVA Hybrid Solar Inverter highlighting 6500VA Rated Power, 80A Max Charge Current, 5500W Max PV Array Power, 120-500Vdc PV Working Voltage, and Battery-free operation.

1.2 Key Features

  • Pure sine wave output.
  • Capable of running without a battery.
  • Built-in 80A MPPT solar controller.
  • Configurable input voltage range for home appliances and personal computers via LCD settings.
  • Configurable battery charging current based on applications via LCD settings.
  • Configurable AC/Solar Charger priority via LCD settings.
  • Compatible with mains voltage or generator power.
  • Automatic restart upon AC recovery.
  • Overload, over temperature, and short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • Integrated BMS (Battery Management System) for enhanced security and maintenance.
  • Supports RS232 communication.
  • Lithium battery activation function.
  • Dry contact for generator start.
  • Mainboard features a waterproof coating for moisture and corrosion resistance.
  • MOSFET pin protection to prevent short circuits from insects.
  • Maximum 500VDC PV input.
  • Large internal wire diameter to reduce heat generation.
  • Supports 50Hz or 60Hz (programmable).
  • Built-in dustproof kit for harsh environments.
  • Intelligent fan for power saving and noise reduction at low/no load.
  • Mix power support for hybrid grid and solar energy supply.

1.3 Basic System Architecture

The inverter/charger can be integrated into a complete running system with the following devices:

  • Generator or Utility power source.
  • PV modules (optional).
  • External Battery Packs (optional, charging voltage adjustable).
Hybrid Power System Diagram
Figure 2: Basic Hybrid Power System Architecture showing connections between Solar Power, Inverter, Battery, Utility/Generator, and Home Appliances.

1.4 Product Overview Diagram

Product Overview with Labeled Parts
Figure 3: Front and bottom view of the inverter with labeled components: 1. LCD display, 2. Status indication, 3. Charging indication, 4. Fault indication, 5. Function keys, 6. Power on/off switch, 7. AC input, 8. Circuit Breaker, 9. Mains input, 10. Touchdown, 11. Mains output, 12. Battery input/output, 13. Solar input, 14. BMS communication port (only parallel), 15. RS232 communication port.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with a battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow the required specifications to select appropriate cable sizes. It is very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow the installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
  10. A fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to the local dealer or service center for maintenance.

3. Setup (Installation)

3.1 Unpacking and Inspection

Before installation, please inspect the unit. Ensure that nothing inside the package is damaged. The package should contain:

  • The unit x 1
  • User manual x 1
  • Parallel wire (only for parallel models) x 1
  • Current equalization wire (only for parallel models) x 1

3.2 Preparation

Before connecting all wirings, remove the bottom cover by unscrewing two screws.

3.3 Mounting the Unit

Consider the following points when selecting an installation location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install the inverter at eye level for easy reading of the LCD display.
  • The ambient temperature should be between 0°C and 55°C for optimal operation.
  • Adhere to the recommended vertical wall-mounted position.
  • Ensure sufficient clearance from other objects and surfaces for heat dissipation and wire removal.

WARNING: Suitable for mounting on concrete or other non-combustible surfaces only.

Install the unit using three M4 or M5 screws.

3.4 Battery Connection

CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the typical amperage table for required fuse or breaker size.

WARNING: Use appropriate cable for battery connection. To reduce risk of injury, use the proper recommended cable stripping length (L2) and tinning length (L1).

Recommended Battery Cable Specifications:

Model Maximum Amperage Battery Capacity Wire Size Cable mm² L1 (mm) L2 (mm) Torque Value
3.5KVA 137A 100AH 2AWG 38 3 18 2-3 Nm
5.5KVA 137A 200AH 2AWG 38 3 18 2-3 Nm

Steps for Battery Connection:

  1. Remove 18 mm of insulation sleeve for positive and negative cables based on recommended stripping length.
  2. Connect all battery packs as required by the unit. It is suggested to use the recommended battery capacity.
  3. Insert the battery cable flatly into the inverter's battery connector and ensure the bolts are tightened with a torque of 2-3 Nm. Verify polarity at both the battery and the inverter/charger.

3.5 AC Input/Output Connection

CAUTION: Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is protected from overcurrent. The recommended AC breaker is 50A.

CAUTION: There are two terminal blocks labeled "IN" and "OUT". Do NOT mis-connect input and output connectors.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection to reduce risk of injury.

Suggested Cable Requirement for AC Wires:

Model Gauge Torque Value
3.5KVA 10AWG 1.4-1.6Nm
5.5KVA 8AWG 1.4-1.6Nm

Steps for AC Input/Output Connection:

  1. Before making AC input/output connections, ensure the DC protector or disconnector is open.
  2. Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. Connect the PE protective conductor (ground) first. (Ground: yellow-green, L: brown or black, N: blue).
  4. Insert AC output wires according to polarities indicated on the terminal block and tighten the terminal screws. Connect the PE protective conductor (ground) first. (Ground: yellow-green, L: brown or black, N: blue).
  5. Ensure all wires are securely connected.

IMPORTANT: When the inverter is in battery mode or standby mode, the neutral of the output is connected to the grounding of the AC output. When in AC mode, the neutral of the output is disconnected from the AC output grounding and connected to the neutral of the AC input.

3.6 PV Connection

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable for PV module connection to reduce risk of injury.

PV Module Selection:

When selecting proper PV modules, consider the following parameters:

  1. Open circuit Voltage (Voc) of PV modules should not exceed the maximum PV array open circuit voltage of the inverter (500VDC).
  2. Open circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.

Solar Charging Mode Specifications:

  • Inverter model: 3.5KVA/5.5KVA
  • Max. PV Array Open Circuit Voltage: 500VDC
  • MPPT Range & Working Voltage: 120-450VDC

Steps for PV Module Wire Connection:

  1. Remove 10 mm of insulation sleeve for positive and negative conductors.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive pole (+) to positive pole (+) of PV input connector. Connect negative pole (-) to negative pole (-) of PV input connector.
  3. Ensure the wires are securely connected.

3.7 Final Assembly

After connecting all wirings, replace the bottom cover by screwing in the two screws.

4. Operating Instructions

4.1 Power ON/OFF

Once the unit is properly installed and batteries are connected (if applicable), simply press the On/Off switch (located on the button of the case) to turn on the unit.

4.2 Operation and Display Panel

The operation and display panel is on the front of the inverter. It includes three indicators, four function keys, and an LCD display to show operating status and input/output power information.

Inverter Display Panel and Connections
Figure 4: Inverter display panel showing LCD display, status indicator, charging indicator, fault indicator, and function buttons. Also shows connection ports for AC input/output, battery, PV, and communication.

LED Indicator

LED Indicator Color State Messages
AC/INV Green Solid On Output is powered by utility in Line mode.
Flashing Output is powered by battery or PV in battery mode.
CHG Green Solid On Battery is fully charged.
Flashing Battery is charging.
FAULT Red Solid On Fault occurs in the inverter.
Flashing Warning condition occurs in the inverter.

Function Keys

Function Key Description
ESC To exit setting mode
UP To go to previous selection
DOWN To go to next selection
ENTER To confirm the selection in setting mode or enter setting mode

4.3 LCD Display Icons

The LCD display shows various icons to indicate the inverter's status and operational information. These include input source, input/output voltage and frequency, battery level, load level, and mode of operation.

4.4 LCD Setting (Programmable Functions)

To enter setting mode, press and hold the ENTER button for 3 seconds. Use the "UP" or "DOWN" buttons to select setting programs, then "ENTER" to confirm or "ESC" to exit.

Key programmable settings include:

  • Program 00: Exit setting mode.
  • Program 01: Output source priority (Utility first, Solar first, SBU priority).
  • Program 02: Maximum charging current (10A, 20A, 30A, 40A, 50A, 60A, 70A, 80A, 90A, 100A).
  • Program 03: AC input voltage range (Appliances: 90-280VAC, UPS: 170-280VAC).
  • Program 05: Battery type (AGM, Flooded, User-Defined).
  • Program 06: Auto restart when overload occurs (Disable/Enable).
  • Program 07: Auto restart when over temperature occurs (Disable/Enable).
  • Program 09: Output frequency (50Hz, 60Hz).
  • Program 10: Output voltage (220V, 230V, 240V).
  • Program 11: Maximum utility charging current (2A, 10A, 20A, 30A, 40A, 50A, 60A).
  • Program 12: Setting voltage point back to utility source (various voltage options for 3.5KW and 5.5KW models).
  • Program 13: Setting voltage point back to battery mode (various voltage options for 3.5KW and 5.5KW models).
  • Program 16: Charger source priority (Utility first, Solar first, Solar and Utility, Only Solar).
  • Program 18: Alarm control (On/Off).
  • Program 19: Auto return to default display screen (Enable/Disable).
  • Program 20: Backlight control (On/Off).
  • Program 22: Beeps while primary source is interrupted (On/Off).
  • Program 23: Overload bypass (Enable/Disable).
  • Program 25: Record Fault code (Enable/Disable).
  • Program 26: Bulk charging voltage (C.V voltage) (Adjustable for 3.5KW/5.5KW models).
  • Program 27: Floating charging voltage (Adjustable for 3.5KW/5.5KW models).
  • Program 28: AC output mode (Single phase, Parallel L1/L2/L3 phase).
  • Program 29: Low DC cut-off voltage (Adjustable for 3.5KW/5.5KW models).
  • Program 30: Battery equalization (Enable/Disable).
  • Program 31: Battery equalization voltage (Adjustable for 3.5KW/5.5KW models).
  • Program 33: Battery equalized time (5-900 mins).
  • Program 34: Battery equalized timeout (5-900 mins).
  • Program 35: Equalization interval (0-90 days).
  • Program 36: Equalization activated immediately (Enable/Disable).
  • Program 37: Communication protocol (PLY for Pylon, FIE for Ritar, Jdb for Jabaida).
  • Program 38: BMS alarm enable (Enable/Disable).
  • Program 39: Discharge cut off Soc (1%-99%).
  • Program 40: Charge stop Soc (30%-100%).
  • Program 41: Restart Soc (10%-99%).
  • Program 42: Grid-parallel operation (FGN/FGS).

4.5 Operating Mode Description

The inverter operates in various modes, each with specific behaviors and display indications:

  • Standby Mode: No output, but can charge batteries from utility or PV.
  • Fault Mode: Errors detected (e.g., over temperature, short circuit). PV energy and utility can still charge batteries.
  • Line Mode: Unit provides output power from mains and charges batteries. If "solar first" is selected, solar and utility can power loads and charge batteries.
  • Battery Mode: Unit provides output power from battery and PV power.

5. Maintenance

5.1 Anti-Dust Kit Clearance and Maintenance

The inverter comes with a pre-installed anti-dust kit to protect internal components and enhance reliability. The inverter automatically detects this kit and adjusts internal thermal sensors.

NOTICE: The anti-dust kit should be cleaned from dust every month.

Steps for Cleaning:

  1. Loosen the screw on the top of the inverter in a counterclockwise direction.
  2. Remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case.
  4. After cleaning, re-assemble the dust-kit back into the inverter.

5.2 Battery Equalization

Battery equalization is a function added to the charge controller to reverse the buildup of negative chemical effects like stratification and sulfation, which can reduce battery capacity. It is recommended to equalize batteries periodically.

How to Apply Equalization Function:

  1. Enable the battery equalization function in monitoring LCD setting program 30.
  2. Apply the function by either setting the equalization interval in program 35 or activating equalization immediately in program 36.

When to Equalize:

In the float stage, when the set equalization interval is reached or equalization is actively initiated, the controller will enter the Equalize stage.

Equalize Charging Time and Timeout:

During the Equalize stage, the controller charges the battery until it reaches the battery equalization voltage. Then, constant-voltage regulation maintains this voltage until the set equalized time is over. If the battery voltage does not reach the equalization voltage when the time expires, the charge controller will extend the time until the voltage is met. If the voltage is still low after the timeout, the charge controller will stop equalization and return to the float stage.

6. Troubleshooting

Refer to the table below for common problems, their possible causes, and recommended solutions.

Problem LCD/LED/Buzzer Explanation / Possible Cause What to do
Unit shuts down automatically during startup. LCD/LEDs and buzzer active for 3 seconds, then off. Battery voltage is too low. 1. Re-charge battery. 2. Replace battery.
No power on after reset. No indication. 1. Battery voltage is too low. 2. Battery polarity is reversed. 1. Check battery wiring. 2. Re-charge/replace battery.
Mains exist but unit works in battery mode. Input voltage displayed as 0, green LED flashing. Input protector is tripped. Check AC breaker and wiring.
Green LED flashing. Insufficient quality of AC power (Shore or Generator). 1. Check AC wires. 2. Check generator or input voltage range setting.
Green LED flashing. "Solar First" set as priority. Change output source priority to Utility first.
Internal relay switches on/off repeatedly. LCD display and LEDs flashing. Battery is disconnected. Check battery wires.
Fault code 07 Overload error (110% and time is up). Reduce connected load.
Fault code 05 Output short circuited. Check wiring, remove abnormal load.
Fault code 02 Internal temperature of inverter component > 100°C. Check air flow, ambient temperature.
Fault code 03 Battery voltage is too high. Check battery specs and quantity.
Fault code 01 Fan fault. Check fan lock, replace fan.
Fault code 06/58 Output abnormal (voltage below 190Vac or above 260Vac). Reduce connected load.
Fault code 08 Bus voltage is too high. Restart device; if fault repeats, contact service.
Fault code 09/53/57 Internal components failed. Contact service or return for repair.
Fault code 51/52/55 Over current or surge, Bus voltage too low, Inverter voltage DC component over. Restart device; if fault repeats, contact service.
Fault code 80 Communication abnormal. Check parallel communication cable connection, restart device. If fault repeats, contact service.

7. Specifications

7.1 Technical Parameters (SC HF 5500-48)

Parameter Value
Model
Model NameSC HF 5500-48 (GGH-6.5KVA)
Rated Power5500VA/5500W
INPUT (AC)
Voltage230V AC
Optional Voltage Range170-280V AC (For Personal Computers), 90-280V AC (For Home Appliances)
Frequency Range50Hz/60Hz (Auto Sensing)
OUTPUT (AC)
AC stabilized voltage230V AC±5%
Surge Power11000VA
Peak efficiency93.5%
Switching time10ms (For Personal Computers); 20ms (For Home Appliances)
Wave formPure Sine Wave
BATTERY
Battery typeLead acid + Lithium battery
Battery voltage range42-60V
Charging curveThree-Stage
Lithium battery charging strategyAdaptive to lithium battery
Solar Charge & AC Charge
Maximum photovoltaic power5500W
Maximum PV open circuit voltage500V DC
MPPT Range & Working Voltage120-450V DC
Maximum Solar Charging Current100A
Maximum AC charging current60A
Solar Charger TypeMPPT
General Data
Product size (mm)302*490*110
Package size (mm)346*536*178
Net Weight (kgs)9.7
Communication InterfaceRS232/RS485CAN/Drycontact
Relative Humidity5% to 95% (Non-condensing)
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C

Note: Product specifications are subject to change without further notice.

7.2 Product Dimensions

Product Dimensions Diagram
Figure 5: Diagram showing the dimensions of the inverter: 302mm (width), 490mm (height), 110mm (depth). Net Weight: 9.7kg.

8. Warranty and Support

The Daxtromn GGH-6.5KVA Hybrid Solar Inverter comes with a 1-year warranty.

For technical support, service, or repair, please contact your local dealer or service center. Do not attempt to disassemble or repair the unit yourself unless you are a qualified service person.

A user manual in PDF format is available for download for more detailed information: Download User Manual (PDF).

9. User Tips

  • Parallel Operation: This inverter supports parallel operation for increased capacity, up to 6 units in single phase or three-phase configurations. Ensure all inverters share the same battery bank and that communication cables are correctly connected. Refer to sections 11 and 12 in the full PDF manual for detailed parallel installation guides and wiring diagrams.
  • Battery-Free Operation: The inverter can operate without batteries. If operating without an external battery, the solar panel input voltage must be above 150VDC for normal operation. With an external battery, 120VDC is sufficient.
  • BMS Communication: If your battery has a BMS (Battery Management System), connect it to the inverter's BMS communication port. This allows the inverter and battery to communicate, automatically adjusting charging voltage, cut-off voltage, and other parameters for optimized battery life and safety. Ensure both the inverter and battery have BMS functions for this feature to work.
  • Generator Start: The dry contact feature can be used to automatically start a generator when battery voltage reaches a warning level.
  • Dust Protection: Regularly clean the anti-dust kit (monthly) to maintain optimal performance and extend the inverter's lifespan, especially in harsh environments.