1. Introduction
This digital turbine flow meter is engineered for precise measurement of liquid flow in various industrial applications. It is suitable for a wide range of fluids including water, petroleum products, chemicals, and certain medical or process fluids. The device is compatible with both aluminum alloy and stainless steel materials, offering flexibility based on application requirements.
Key features include a high-definition LCD display for real-time monitoring of instantaneous and cumulative flow. It supports external power supply with standard pulse output and optional RS485 signal output for seamless system integration. The meter is designed to automatically switch to battery mode when external power is unavailable, ensuring continuous operation.
2. Specifications
The following table details the technical specifications of the turbine flow meter:
Figure 1: Product Parameters and Specifications
| Parameter | Specification |
|---|---|
| Material | Aluminum Alloy / Stainless Steel (optional) |
| Caliber | DN20, DN25, DN32, DN40, DN50 |
| Power Supply | 5V–24V external power (pulse output, RS485 optional) / AAA battery (no output) |
| Medium | Petroleum, Chemicals, Medicine, Water |
| Accuracy | ±0.5% |
| Repeatability | ±0.3% |
| Max Working Pressure | 1.0 MPa |
| Flow Range | 0.1–50 L/min |
| Display Units | QTS, PTS, L, GAL, m³ |
| Single Count Range | 0.00–9999.9 |
| Total Accumulation Range | 0–99999.9 |
| Display Type | LCD, simultaneous instantaneous and total flow display |
| Standby Time | Up to 1 year (battery mode) |
For more detailed specifications, please refer to the official user manual PDF: User Manual (PDF).
3. Setup and Installation
3.1. Preparation
- Ensure the selected material of the flow meter is compatible with the liquid to be measured.
- Verify the correct caliber and connection type (threaded, clamp, or flange) for your pipeline.
- Install the flow meter in the pipeline according to the flow direction indicated on its housing.
- Before installation, ensure the pipeline is thoroughly flushed and free of any debris.
- If signal output (pulse or RS485) is required, connect an external DC power supply (5V-24V).
- If using battery mode, install AAA batteries.
3.2. Installation Precautions
- Install the flow meter at a lower position in horizontal pipelines or in an upward vertical section. Avoid installing at the highest point of the pipeline or in downward vertical sections.
Figure 2: Installation in Horizontal Pipelines
- The sensor must never be installed at the pump inlet; it should be installed at the pump outlet.
- Ensure there is at least 10D (D = inner diameter of the flow meter) length of straight pipe upstream of the flow meter, and 5D length of straight pipe downstream.
Figure 3: Pump Inlet and Straight Pipe Length Requirements
- If the pipeline drop exceeds 5 meters, install an air release valve downstream of the sensor.
- The flow meter should be installed at a rising section of the pipeline.
Figure 4: Installation in a Rising Pipeline Section
4. Operation
4.1. Initial Start-up
- Slowly open the valve to allow liquid to pass through the turbine smoothly.
- Avoid sudden pressure surges, which can damage the turbine.
- When powered externally, the device outputs a pulse signal by default. RS485 output is available if configured.
- If external power is disconnected, the device automatically switches to battery mode for display-only operation.
4.2. Data Reading
The high-definition LCD display shows both the instantaneous flow rate and the cumulative total flow simultaneously.
Figure 5: LCD Display Overview
- Use the display interface to view single count and total accumulation values.
- Confirm the measurement unit displayed (QTS, PTS, L, GAL, m³) before recording data.
- The display head is rotatable 360 degrees for optimal viewing angles.
Figure 6: High-Definition Real-time Display
5. Maintenance
- Store the device in a dry, well-ventilated environment, away from corrosive gases.
- Clean the exterior of the flow meter with a soft, dry cloth. Do not use aggressive solvents.
- If the device will not be used for an extended period, remove the batteries to prevent leakage.
- Periodically inspect the turbine rotor for any signs of contamination or wear.
- Calibration is recommended at regular intervals according to industry standards to maintain accuracy.
6. Troubleshooting
- Inaccurate Readings or Device Damage: Ensure the flow meter is used within its specified pressure and flow range. Do not exceed the maximum working pressure of 1.0 MPa.
- Turbine Damage or Inaccuracy: Ensure the measured liquid is clean and free of large solid particles. Filter the liquid if necessary.
- Device Damage from Vibration: Avoid strong mechanical vibration and impact during installation and operation.
- Device Not Powering On or Incorrect Readings (Battery Mode): Replace batteries only with the specified AAA type. Do not mix old and new batteries.
- Communication Errors (RS485): Ensure proper grounding when using RS485 communication to reduce electromagnetic interference.
7. User Tips
- Optimal Viewing: The display head is rotatable 360 degrees. Adjust it to your preferred viewing angle for easy monitoring of flow data.
- Enhanced Signal Stability: While the intelligent chip provides anti-interference, always ensure proper grounding for RS485 communication in environments with high electromagnetic noise to maximize signal integrity.
- Prolonging Lifespan: Regularly inspect the one-piece impeller for any signs of wear or debris, especially when measuring fluids that may contain fine particles, to ensure long-term reliable operation.
- Battery Life: In battery-only mode, the device is for display only. For continuous signal output, always use an external power supply.
8. Frequently Asked Questions (FAQs)
- Q1: How do I choose the correct caliber?
- Choose the caliber based on your existing pipe size and the expected flow rate to ensure optimal performance and accurate measurement.
- Q2: Can this meter be used with corrosive liquids?
- Yes, for corrosive media, it is highly recommended to select the stainless steel version of the flow meter for enhanced chemical resistance and durability.
- Q3: What happens if external power is disconnected?
- The system will automatically switch to AAA battery power, maintaining display functionality. Please note that signal output will be unavailable when operating solely on battery power.
9. Safety Warnings
- Risk of Electric Shock: Always ensure power is disconnected before wiring or performing any maintenance when using an external power supply.
- Pressurized Pipeline Hazard: Release system pressure completely before attempting any installation or removal of the flow meter.
- Explosive Atmospheres: This device is not suitable for explosive atmospheres unless specifically certified accordingly. Explosion-proof capability must be verified by the seller.
- Chemical Compatibility: Do not use the flow meter with incompatible or highly corrosive fluids unless the stainless steel version is selected and chemical compatibility is confirmed.
- Child Safety: Keep out of reach of children.
- Proper Disposal: Follow WEEE directives for electronic waste disposal.
Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.
10. Warranty and Support
For any technical assistance, warranty claims, or support inquiries, please contact the seller directly using the information below. We also offer customized products tailored to meet specific needs for any occasion. For bulk orders or technical consultations, feel free to reach out.