VaneAims Voltage Relay Protector User Manual

Model: Voltage Relay Protector 40A/63A/80A

1. Introduction

The VaneAims Voltage Relay Protector is a versatile device designed to safeguard electrical equipment from voltage fluctuations and overcurrent conditions. It provides comprehensive protection against overvoltage, undervoltage, and overcurrent, featuring an intelligent chip for precise control, automatic reset functionality, and a high-definition digital display for real-time monitoring. This manual provides detailed instructions for installation, operation, and maintenance.

VaneAims Voltage Relay Protector overview showing different models and protection features.

Figure 1: VaneAims Voltage Relay Protector models and key features. The device offers overvoltage, undervoltage, and overcurrent protection, features an intelligent chip, automatic reset, and a high-definition digital display. Available in AC220V with 40A, 63A, or 80A ratings.

2. Product Features and Versions

2.1 Key Advantages

  • Improved Button Design: For easier pressing and operation.
  • Brand Logo Customization: Supports brand logo display.
  • Higher-Resolution Screen: Provides clear and precise readings.
  • Real-time Measurement: Measures and displays voltage, current, power, and energy values in real-time.
  • 35mm Din Rail Mounting: Equipped with securing clips for easy and secure installation.
Product advantages including improved buttons, logo customization, high-resolution screen, real-time measurement, and Din Rail mounting.

Figure 2: Product advantages highlighting user-friendly design and installation features.

2.2 Available Versions

The VaneAims Voltage Relay Protector is available in several versions to suit different monitoring needs:

  • Regular Version: Displays Voltage (V) and Amperage (A).
  • Upgraded Version: Also displays Voltage (V) and Amperage (A), with enhanced features.
  • VA kWh Version: Displays Voltage (V), Amperage (A), and Kilowatt-hours (kWh) – a 3-in-1 display.
  • All-in-One Version: Displays Voltage (V), Amperage (A), Kilowatt-hours (kWh), Watts (W), and Hertz (Hz) – a 5-in-1 comprehensive display.
Four versions of the voltage protector: Regular, Upgraded, kWh, and All-in-One, showing their respective display capabilities.

Figure 3: Different product versions and their display capabilities.

3. Specifications

ParameterSpecification
Supply TerminalsN, L
Rated Supply VoltageAC 220V (Range: DC 85-300V)
Rated Frequency40/50/60/70Hz
Overvoltage Setting Range (>V)AC130-300V / DC130-300V (All-in-One: AC240-300V)
Undervoltage Setting Range (<V)AC80-210V / DC85-210V (All-in-One: AC140-230V)
Voltage Hysteresis5V
Overvoltage Trip Delay0.5s
Voltage Accuracy<1%
Max. Operating Phase Voltage350V
Max. Operating Current40A/63A/80A (Some models up to 100A)
Altitude≤2000m
Delay Time (Recovery/Power-on)5-300s (Power-on/Recovery: 1s-999s)
Permissible Relative Humidity≤50% at 40°C (without condensation)
Ambient Temperature-25°C ~ +55°C
Size81*36*66mm
CertificationCE, RoHS
Detailed technical specifications table for the voltage relay protector.

Figure 4: Comprehensive technical specifications for the VaneAims Voltage Relay Protector.

4. Setup and Installation

4.1 Mounting

The VaneAims Voltage Relay Protector is designed for 35mm Din Rail mounting. Ensure the device is securely clipped onto the Din Rail in a suitable electrical enclosure, away from direct moisture or excessive heat.

4.2 Wiring Diagram

Connect the device according to the wiring diagrams below. Ensure all connections are tight and correct to prevent malfunction or damage.

Wiring diagram and front panel description for the VA kWh version of the voltage protector.

Figure 5: Wiring diagram for VA kWh version. Connect the Neutral (N) and Live (L) wires to the 'IN' terminals at the top and the protected load to the 'OUT' terminals at the bottom. The front panel shows Voltage, Current, and kWh displays, along with 'SET', 'Up/Digit+', 'Down/Digit-', and 'ON/OFF' buttons.

Wiring diagram and front panel description for the Regular/Upgraded versions of the voltage protector.

Figure 6: Wiring diagram for Regular/Upgraded versions. Connect the Neutral (N) and Live (L) wires to the 'IN' terminals at the top and the protected load to the 'OUT' terminals at the bottom. The front panel includes indicators for Overvoltage, Undervoltage, Overcurrent, and Normal Working, along with Volt and Current displays, 'SET', 'Digit-/Down', 'Digit+/Up', and 'ON/OFF' buttons.

5. Operating Instructions

5.1 Front Panel Overview

The front panel features a digital display, control buttons, and status indicators:

  • Digital Display: Shows real-time voltage, current, power, energy, and frequency depending on the model.
  • SET Button: Used to enter and confirm settings.
  • Up/Digit+ Button: Used to navigate menus or increase values.
  • Down/Digit- Button: Used to navigate menus or decrease values.
  • ON/OFF Button: Toggles the output power.
  • Indicators: (For Regular/Upgraded versions) Separate LEDs for Overvoltage (>V), Undervoltage (<V), Overcurrent (>A), and Normal Working (POWER).

5.2 Setting Instructions

To adjust protection parameters:

  1. Enter Settings: Long press the 'SET' button for 5 seconds until the display enters the setting mode (e.g., P-1 will appear).
  2. Navigate Parameters: Use the 'Up/Digit+' and 'Down/Digit-' buttons to cycle through the different setting parameters (P-1, P-2, etc.).
  3. Adjust Values: Once the desired parameter is displayed, press 'SET' again. The value will start blinking. Use 'Up/Digit+' and 'Down/Digit-' buttons to adjust the value. For quicker adjustments over longer ranges, press and hold the Up or Down key.
  4. Save Settings: After setting the desired value, press 'SET' again to confirm and save. The display will stop blinking.
  5. Exit Settings: Continue pressing 'SET' to cycle through all parameters or wait for a timeout to automatically exit the setting mode.

Common Setting Parameters (may vary by version):

  • P-1 Overvoltage Setting: Set the upper voltage limit (e.g., 240-300V).
  • P-2 Overvoltage Delay Time: Set the delay before tripping on overvoltage (e.g., 5-300s).
  • P-3 Undervoltage Setting: Set the lower voltage limit (e.g., 80-210V).
  • P-4 Undervoltage Delay Time: Set the delay before tripping on undervoltage (e.g., 5-300s).
  • P-5 Overcurrent Setting: Set the maximum current limit (e.g., 1A-80A).
  • P-1 Power-on Delay Time: Set the delay before power output after device startup (e.g., 1s-999s).
  • P-2 Recovery Delay: Set the delay before automatic reconnection after a fault trip (e.g., 1s-999s).
  • Password Setting (P-13/P-19): Set or change the device password (default often 112).

Refer to Figures 5 and 6 for specific setup menus for your version.

5.3 Operation Demonstration

Video 1: Product demonstration showing how to adjust settings for current, kWh, and regular versions. The video also demonstrates overvoltage, undervoltage, and overcurrent protection tests.

6. Maintenance

The VaneAims Voltage Relay Protector is designed for reliable operation with minimal maintenance. To ensure optimal performance and longevity:

  • Keep Clean: Periodically wipe the device with a dry, soft cloth to remove dust and debris. Do not use abrasive cleaners or solvents.
  • Check Connections: Ensure all wiring connections remain tight and secure. Loose connections can lead to overheating or intermittent operation.
  • Environmental Conditions: Operate the device within its specified ambient temperature and humidity ranges. Avoid exposure to direct moisture or corrosive environments.

7. Troubleshooting

If the device is not functioning as expected, consider the following:

  • No Display/No Power: Check the input voltage supply and ensure it is within the rated range. Verify wiring connections.
  • Device Trips Frequently:
    • Overvoltage/Undervoltage Trip: Check the actual line voltage. Verify that the overvoltage (>V) and undervoltage (<V) settings are appropriate for your application.
    • Overcurrent Trip: Check the load connected to the device. Ensure the load current does not exceed the set overcurrent limit (>A). Reduce the load or adjust the overcurrent setting if necessary (within safe limits).
  • Device Does Not Reset Automatically: Check the recovery delay setting (P-2). Ensure the 'Automatic Reset' function is enabled if available in your model's settings (e.g., P16 for Regular/Upgraded versions).
  • Incorrect Readings: If readings appear inaccurate, check the voltage/current correction settings (P-6 for voltage, P12 for current) and ensure they are set to default or calibrated correctly.

If issues persist, consult the detailed PDF manual or contact customer support.

8. User Tips

  • Always ensure the device's current rating (40A, 63A, 80A) matches or exceeds the maximum current draw of your connected load.
  • When setting protection thresholds, allow for a small buffer to prevent nuisance tripping during minor fluctuations.
  • For critical applications, regularly verify the device's settings and functionality.

9. Warranty and Support

For detailed warranty information, technical support, or service inquiries, please refer to the seller's terms or contact the VaneAims customer service directly. Please have your product model and purchase details ready when contacting support.

A comprehensive user manual in PDF format is available for download: View User Manual (PDF)