ANENJI ANJ-3KW-24V-LV WIFI

Contents

ANENJI Hybrid Solar Inverter User Manual

Model: ANJ-3KW-24V-LV WIFI

1. Product Overview

The ANENJI Hybrid Solar Inverter is a multi-functional device combining the functions of an inverter, solar charger, and battery charger to offer uninterruptible power support. Its comprehensive LCD display allows user-configurable and easy-accessible button operations such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

ANENJI Hybrid Solar Inverter Rear and Side View with Labeled Ports
Figure 1: Inverter Overview and Port Identification
This diagram shows the rear and side panels of the inverter with numbered components for easy identification.
  1. AC input
  2. AC output
  3. PV input
  4. Battery input
  5. Grounding
  6. RS485 communication port
  7. Built-in WiFi
  8. Power on/off switch
  9. LCD display
  10. Status indicator
  11. Charging indicator
  12. Fault indicator
  13. Function buttons
  14. Dry contact port
Hybrid Solar Inverter System Connection Diagram
Figure 2: Typical System Connection Diagram
Illustrates how the inverter integrates with solar panels, a generator, utility grid, battery bank, and home loads.

2. Setup and Installation

2.1 Unpacking and Inspection

Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain:

  • Inverter Unit x 1
  • User Manual x 1
  • WiFi Antenna x 1

2.2 Preparation

Before connecting any wiring, remove the bottom cover of the inverter by unscrewing the two screws located at the bottom.

2.3 Mounting the Unit

Select a suitable location for mounting the inverter by considering the following:

  • Do not mount on flammable construction materials.
  • Mount on a solid surface.
  • Install at eye level for easy LCD display reading.
  • Ambient temperature should be between $0^{\circ}C$ and $55^{\circ}C$.
  • Mount vertically as recommended.
  • Ensure adequate clearance (at least 20cm on sides, 50cm top/bottom) for heat dissipation and wiring access.

CAUTION: Suitable for mounting on concrete or other non-combustible surfaces only.

2.4 Battery Connection

WARNING: All wiring must be performed by qualified personnel. For safety, install a separate DC over-current protector or disconnect device between the battery and inverter. Use appropriate cable sizes and terminals as specified in the manual (e.g., for 3KVA, 137A, 200AH battery, use 2AWG wire, 35 $mm^2$ cable, with terminals for 4-6 Nm torque).

  1. Prepare battery positive and negative cables according to specifications.
  2. Connect all battery packs as required.
  3. Insert battery cables into the inverter's battery connector and tighten bolts to 4-6 Nm. Ensure correct polarity.

2.5 AC Input/Output Connection

CAUTION: Before connecting to the AC input power source, install a separate AC breaker (recommended 50A) between the inverter and the AC source. This ensures safe disconnection and over-current protection. Do not mis-connect input and output terminals.

  1. Open DC protector/disconnector before making AC connections.
  2. Remove 10mm insulation from conductors.
  3. Insert AC input wires according to polarities (L, N, Ground) and tighten terminals.
  4. Insert AC output wires according to polarities (L, N, Ground) and tighten terminals.
  5. Ensure all wires are securely connected.

WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.

2.6 PV Connection

CAUTION: Install a DC circuit breaker between PV modules and the inverter. Ensure correct polarity when connecting PV modules to the inverter's PV input connectors.

PV Module Selection: Ensure PV array open circuit voltage (Voc) does not exceed 500VDC and is higher than the minimum battery voltage. Max PV input current is 27A.

2.7 Final Assembly

After all wiring is complete, reattach the bottom cover of the inverter by screwing in the two screws.

2.8 Wiring Guide Video

For a visual guide on wiring the inverter, please watch the official wiring guide video:

Video 1: ANENJI Solar Inverter Wiring Guide
This video demonstrates the step-by-step process of wiring the ANJ-3KW-24V-LV-WIFI solar inverter, including connecting AC output and battery.

3. Operating Instructions

3.1 Power ON/OFF

Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the bottom of the case) to power on the unit.

3.2 Operation and Display Panel

The front panel features an LCD display, three LED indicators, and four function keys to show operating status and power information.

  • LED Indicators:
    • AC/INV (Green): Solid On for utility power, Flashing for battery/PV power.
    • CHG (Green): Solid On for fully charged battery, Flashing for charging battery.
    • FAULT (Red): Solid On for fault, Flashing for warning condition.
  • Function Keys:
    • ESC: Exit setting mode.
    • UP: Go to previous selection.
    • DOWN: Go to next selection.
    • ENTER: Confirm selection or enter setting mode.

3.3 LCD Setting

Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN to select programs and ENTER to confirm. ESC exits the mode.

Key configurable settings include:

  • Output Source Priority (Program 01): Configure load power source priority (Utility first, Solar first, SBU priority, SUB priority, SUF priority).
  • Maximum Charging Current (Program 02): Set total charging current for solar and utility chargers.
  • AC Input Voltage Range (Program 03): Select voltage range for appliances or generators.
  • Battery Type (Program 05): Select AGM, Flooded, User-Defined, or Lithium battery types.
  • Output Voltage (Program 08): Set output voltage (110V, 115V, 120V).
  • Output Frequency (Program 09): Set output frequency (50Hz, 60Hz).
  • Battery Equalization (Program 33): Enable or disable battery equalization.

3.4 Dry Contact Signal

A dry contact (3A/250VAC) on the rear panel can deliver a signal to an external device when battery voltage reaches a warning level. It can indicate power off, utility power, or battery/solar power status based on battery voltage thresholds.

3.5 Battery Equalization

This function reverses negative chemical effects like stratification and removes sulfate crystals, extending battery life. It can be applied by setting an equalization interval (Program 37) or activating immediately (Program 39). The inverter enters an Equalize stage to charge the battery to the equalization voltage for a set time.

3.6 Setting for Lithium Battery

If using a lithium battery, connect the RS485 port of the battery to the inverter's BMS(RS485) communication port. This enables communication for charging voltage, current, and discharge cut-off voltage adjustments based on battery parameters. Configure Program 05 to 'Lithium Battery' and adjust related settings (e.g., Program 12, 13, 29, 31, 41, 42).

4. Maintenance

  • Keep the inverter clean and free from dust.
  • Regularly check all electrical connections for tightness and signs of corrosion.
  • Ensure proper ventilation around the unit to prevent overheating.
  • Periodically inspect the battery terminals for corrosion and clean if necessary.
  • Refer to the troubleshooting section for any operational issues.

5. Troubleshooting

This section provides guidance for common issues. For complex problems, contact technical support.

5.1 Fault Reference Code

The inverter displays specific fault codes on the LCD to indicate issues:

Fault CodeFault Event
01Over temperature of inverter module
02Over temperature of DCDC module
03Battery voltage is too high
04Over temperature of PV module
05Output short circuited.
06Output voltage is too high.
07Overload time out
08Bus voltage is too high
09Bus soft start failed
10PV over current
11PV over voltage
12DCDC over current
13Over current or surge
14Bus voltage is too low
15Inverter failed (Self-checking)
18Op current offset is too high
19Inverter current offset is too high
20DC/DC current offset is too high
21PV current offset is too high
22Output voltage is too low
23Inverter negative power

5.2 Warning Indicator

The inverter also provides warning codes and audible alarms for various conditions:

Warning CodeWarning EventAudible Alarm
02Temperature is too HighBeep three times every second
04Low batteryBeep once every second
07OverloadBeep once every 0.5 second
10Output power deratingBeep twice every 3 seconds
14Fan blockedNone
15PV energy is lowBeep twice every 3 seconds
19Lithium Battery communication is failedBeep once every 0.5 second
21Lithium Battery over currentNone
E9Battery equalizationNone
bPBattery is not connectedNone

5.3 General Troubleshooting

ProblemExplanation / Possible causeWhat to do
Unit shuts down automatically during startup process.The battery voltage is too low1. Re-charge battery. 2. Replace battery.
No response after power on.1. The battery voltage is far too low. 2. Battery polarity is connected reversed.1. Check if batteries and the wiring are connected well. 2. Re-charge battery. 3. Replace battery.
Mains exist but the unit works in battery mode.Insufficient quality of AC power. (Shore or Generator)1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct.
When the unit is turned on, internal relay is switched on and off repeatedly.Battery is disconnected.Check if battery wires are connected well.
Buzzer beeps continuously and red LED is on.Battery is over-charged.Return to repair center.

6. Specifications

6.1 Line Mode Specifications

ParameterSpecification
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage120Vac
Low Loss Voltage95Vac±7V (UPS) / 70Vac±7V (Appliances)
High Loss Voltage140Vac±7V
Max AC Input Voltage150Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

6.2 Inverter Mode Specifications

ParameterSpecification
Rated Output Power3.0KVA/3.0KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation120Vac±5%
Output Frequency50Hz or 60Hz
Peak Efficiency94%
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage24Vdc
Cold Start Voltage23.0Vdc
No Load Power Consumption<55W

6.3 Charge Mode Specifications

ParameterSpecification
Max Charging Current (PV+AC)100Amp
Max Charging Current (AC)60Amp
Bulk Charging Voltage (Flooded Battery)29.2Vdc
Bulk Charging Voltage (AGM / Gel Battery)28.2Vdc
Floating Charging Voltage27Vdc
Overcharge Protection32Vdc
Max. PV Array Open Circuit Voltage500Vdc
PV Array MPPT Voltage Range60Vdc~500Vdc
Max. Input Current27A

6.4 General Specifications

ParameterSpecification
Operating Temperature Range-10°C to 55°C
Storage temperature-15°C~60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H)350x312x110 mm
Net Weight6.9 kg

7. User Tips

  • Easy Monitoring: The inverter works perfectly out of the box, and the software download allows for easy monitoring and configuration of the system.
  • Integrated WiFi: This model comes with its WiFi module pre-installed from the factory, eliminating the need to purchase it separately.
  • Robust Performance: Users have noted the inverter's robust quality and consistent performance relative to its price.
  • Versatile Applications: The inverter can be used for various applications, with users successfully running both sheds and homes from these units.

8. Warranty and Support

This ANENJI Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase, covering manufacturing defects. For technical support, troubleshooting assistance beyond this manual, or warranty claims, please contact your vendor or the ANENJI customer service department.

© 2024 ANENJI. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.