1. Product Overview
The ANENJI Hybrid Solar Inverter is a multi-functional device combining the functions of an inverter, solar charger, and battery charger to offer uninterruptible power support. Its comprehensive LCD display allows user-configurable and easy-accessible button operations such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.

This diagram shows the rear and side panels of the inverter with numbered components for easy identification.
- AC input
- AC output
- PV input
- Battery input
- Grounding
- RS485 communication port
- Built-in WiFi
- Power on/off switch
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Dry contact port

Illustrates how the inverter integrates with solar panels, a generator, utility grid, battery bank, and home loads.
2. Setup and Installation
2.1 Unpacking and Inspection
Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain:
- Inverter Unit x 1
- User Manual x 1
- WiFi Antenna x 1
2.2 Preparation
Before connecting any wiring, remove the bottom cover of the inverter by unscrewing the two screws located at the bottom.
2.3 Mounting the Unit
Select a suitable location for mounting the inverter by considering the following:
- Do not mount on flammable construction materials.
- Mount on a solid surface.
- Install at eye level for easy LCD display reading.
- Ambient temperature should be between $0^{\circ}C$ and $55^{\circ}C$.
- Mount vertically as recommended.
- Ensure adequate clearance (at least 20cm on sides, 50cm top/bottom) for heat dissipation and wiring access.
CAUTION: Suitable for mounting on concrete or other non-combustible surfaces only.
2.4 Battery Connection
WARNING: All wiring must be performed by qualified personnel. For safety, install a separate DC over-current protector or disconnect device between the battery and inverter. Use appropriate cable sizes and terminals as specified in the manual (e.g., for 3KVA, 137A, 200AH battery, use 2AWG wire, 35 $mm^2$ cable, with terminals for 4-6 Nm torque).
- Prepare battery positive and negative cables according to specifications.
- Connect all battery packs as required.
- Insert battery cables into the inverter's battery connector and tighten bolts to 4-6 Nm. Ensure correct polarity.
2.5 AC Input/Output Connection
CAUTION: Before connecting to the AC input power source, install a separate AC breaker (recommended 50A) between the inverter and the AC source. This ensures safe disconnection and over-current protection. Do not mis-connect input and output terminals.
- Open DC protector/disconnector before making AC connections.
- Remove 10mm insulation from conductors.
- Insert AC input wires according to polarities (L, N, Ground) and tighten terminals.
- Insert AC output wires according to polarities (L, N, Ground) and tighten terminals.
- Ensure all wires are securely connected.
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
2.6 PV Connection
CAUTION: Install a DC circuit breaker between PV modules and the inverter. Ensure correct polarity when connecting PV modules to the inverter's PV input connectors.
PV Module Selection: Ensure PV array open circuit voltage (Voc) does not exceed 500VDC and is higher than the minimum battery voltage. Max PV input current is 27A.
2.7 Final Assembly
After all wiring is complete, reattach the bottom cover of the inverter by screwing in the two screws.
2.8 Wiring Guide Video
For a visual guide on wiring the inverter, please watch the official wiring guide video:
This video demonstrates the step-by-step process of wiring the ANJ-3KW-24V-LV-WIFI solar inverter, including connecting AC output and battery.
3. Operating Instructions
3.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the bottom of the case) to power on the unit.
3.2 Operation and Display Panel
The front panel features an LCD display, three LED indicators, and four function keys to show operating status and power information.
- LED Indicators:
- AC/INV (Green): Solid On for utility power, Flashing for battery/PV power.
- CHG (Green): Solid On for fully charged battery, Flashing for charging battery.
- FAULT (Red): Solid On for fault, Flashing for warning condition.
- Function Keys:
- ESC: Exit setting mode.
- UP: Go to previous selection.
- DOWN: Go to next selection.
- ENTER: Confirm selection or enter setting mode.
3.3 LCD Setting
Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN to select programs and ENTER to confirm. ESC exits the mode.
Key configurable settings include:
- Output Source Priority (Program 01): Configure load power source priority (Utility first, Solar first, SBU priority, SUB priority, SUF priority).
- Maximum Charging Current (Program 02): Set total charging current for solar and utility chargers.
- AC Input Voltage Range (Program 03): Select voltage range for appliances or generators.
- Battery Type (Program 05): Select AGM, Flooded, User-Defined, or Lithium battery types.
- Output Voltage (Program 08): Set output voltage (110V, 115V, 120V).
- Output Frequency (Program 09): Set output frequency (50Hz, 60Hz).
- Battery Equalization (Program 33): Enable or disable battery equalization.
3.4 Dry Contact Signal
A dry contact (3A/250VAC) on the rear panel can deliver a signal to an external device when battery voltage reaches a warning level. It can indicate power off, utility power, or battery/solar power status based on battery voltage thresholds.
3.5 Battery Equalization
This function reverses negative chemical effects like stratification and removes sulfate crystals, extending battery life. It can be applied by setting an equalization interval (Program 37) or activating immediately (Program 39). The inverter enters an Equalize stage to charge the battery to the equalization voltage for a set time.
3.6 Setting for Lithium Battery
If using a lithium battery, connect the RS485 port of the battery to the inverter's BMS(RS485) communication port. This enables communication for charging voltage, current, and discharge cut-off voltage adjustments based on battery parameters. Configure Program 05 to 'Lithium Battery' and adjust related settings (e.g., Program 12, 13, 29, 31, 41, 42).
4. Maintenance
- Keep the inverter clean and free from dust.
- Regularly check all electrical connections for tightness and signs of corrosion.
- Ensure proper ventilation around the unit to prevent overheating.
- Periodically inspect the battery terminals for corrosion and clean if necessary.
- Refer to the troubleshooting section for any operational issues.
5. Troubleshooting
This section provides guidance for common issues. For complex problems, contact technical support.
5.1 Fault Reference Code
The inverter displays specific fault codes on the LCD to indicate issues:
| Fault Code | Fault Event |
|---|---|
| 01 | Over temperature of inverter module |
| 02 | Over temperature of DCDC module |
| 03 | Battery voltage is too high |
| 04 | Over temperature of PV module |
| 05 | Output short circuited. |
| 06 | Output voltage is too high. |
| 07 | Overload time out |
| 08 | Bus voltage is too high |
| 09 | Bus soft start failed |
| 10 | PV over current |
| 11 | PV over voltage |
| 12 | DCDC over current |
| 13 | Over current or surge |
| 14 | Bus voltage is too low |
| 15 | Inverter failed (Self-checking) |
| 18 | Op current offset is too high |
| 19 | Inverter current offset is too high |
| 20 | DC/DC current offset is too high |
| 21 | PV current offset is too high |
| 22 | Output voltage is too low |
| 23 | Inverter negative power |
5.2 Warning Indicator
The inverter also provides warning codes and audible alarms for various conditions:
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 02 | Temperature is too High | Beep three times every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 14 | Fan blocked | None |
| 15 | PV energy is low | Beep twice every 3 seconds |
| 19 | Lithium Battery communication is failed | Beep once every 0.5 second |
| 21 | Lithium Battery over current | None |
| E9 | Battery equalization | None |
| bP | Battery is not connected | None |
5.3 General Troubleshooting
| Problem | Explanation / Possible cause | What to do |
|---|---|---|
| Unit shuts down automatically during startup process. | The battery voltage is too low | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | 1. The battery voltage is far too low. 2. Battery polarity is connected reversed. | 1. Check if batteries and the wiring are connected well. 2. Re-charge battery. 3. Replace battery. |
| Mains exist but the unit works in battery mode. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. |
| When the unit is turned on, internal relay is switched on and off repeatedly. | Battery is disconnected. | Check if battery wires are connected well. |
| Buzzer beeps continuously and red LED is on. | Battery is over-charged. | Return to repair center. |
6. Specifications
6.1 Line Mode Specifications
| Parameter | Specification |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 120Vac |
| Low Loss Voltage | 95Vac±7V (UPS) / 70Vac±7V (Appliances) |
| High Loss Voltage | 140Vac±7V |
| Max AC Input Voltage | 150Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
6.2 Inverter Mode Specifications
| Parameter | Specification |
|---|---|
| Rated Output Power | 3.0KVA/3.0KW |
| Output Voltage Waveform | Pure Sine Wave |
| Output Voltage Regulation | 120Vac±5% |
| Output Frequency | 50Hz or 60Hz |
| Peak Efficiency | 94% |
| Surge Capacity | 2* rated power for 5 seconds |
| Nominal DC Input Voltage | 24Vdc |
| Cold Start Voltage | 23.0Vdc |
| No Load Power Consumption | <55W |
6.3 Charge Mode Specifications
| Parameter | Specification |
|---|---|
| Max Charging Current (PV+AC) | 100Amp |
| Max Charging Current (AC) | 60Amp |
| Bulk Charging Voltage (Flooded Battery) | 29.2Vdc |
| Bulk Charging Voltage (AGM / Gel Battery) | 28.2Vdc |
| Floating Charging Voltage | 27Vdc |
| Overcharge Protection | 32Vdc |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc |
| Max. Input Current | 27A |
6.4 General Specifications
| Parameter | Specification |
|---|---|
| Operating Temperature Range | -10°C to 55°C |
| Storage temperature | -15°C~60°C |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
| Dimension (D*W*H) | 350x312x110 mm |
| Net Weight | 6.9 kg |
7. User Tips
- Easy Monitoring: The inverter works perfectly out of the box, and the software download allows for easy monitoring and configuration of the system.
- Integrated WiFi: This model comes with its WiFi module pre-installed from the factory, eliminating the need to purchase it separately.
- Robust Performance: Users have noted the inverter's robust quality and consistent performance relative to its price.
- Versatile Applications: The inverter can be used for various applications, with users successfully running both sheds and homes from these units.
8. Warranty and Support
This ANENJI Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase, covering manufacturing defects. For technical support, troubleshooting assistance beyond this manual, or warranty claims, please contact your vendor or the ANENJI customer service department.