OMRON G5V-2

Rate this product if you’ve used it
Contents

OMRON G5V-2 Series Signal Relays User Manual

Models: G5V-2-5VDC, G5V-2-12VDC, G5V-2-24VDC

1. Introduction

This manual provides essential information for the safe and effective use of your OMRON G5V-2 series signal relays. Please read all instructions carefully before installation and operation. These relays are designed for general signal switching applications, featuring a compact 8-pin, two open two closed (DPDT) configuration.

2. Safety & Warnings

Important Safety Information:

  • Read all instructions before use. Failure to follow these instructions may result in damage to the product or personal injury.
  • Keep small parts of the device out of reach of children under 3 years old.
  • Keep away from children unless supervised by an adult.
  • Do not use this product for purposes other than its intended use.
  • Inspect the product before each use; do not use if damaged.
  • Follow installation and operation guidelines to avoid injury.
  • Do not expose to water or moisture.

Compliance Information: This product bears the CE mark, indicating compliance with European safety, health, and environmental protection requirements.

3. Specifications

FeatureDescription
Product NameSignal Relay
Model SeriesG5V-2
Available ModelsG5V-2-5VDC, G5V-2-12VDC, G5V-2-24VDC
Contact ConfigurationTwo open two closed (DPDT / 2 Form C)
Current Rating2A
Pin Configuration8-PIN
Coil Voltage Options5VDC, 12VDC, 24VDC
OriginMainland China
Approx. Package Dimensions (L x W x H)10 cm x 10 cm x 10 cm
Approx. Package Weight0.12 kg
Batch/Serial Number854825500
ManufacturerShenzhen chengguo technology co., Itd

For detailed technical specifications, please refer to the official OMRON G5V-2 series datasheet.

4. Setup and Installation

The OMRON G5V-2 series relays are designed for PCB mounting or use with compatible relay sockets. Ensure the power supply is disconnected before beginning installation.

  1. Unpacking: Carefully remove the relay from its packaging. Inspect for any visible damage. If damaged, do not use.
  2. Pin Identification: Identify the coil pins and contact pins. The relay features 8 pins. Refer to the diagrams below for typical pin layouts.
Front view of three G5V-2 series relays (5VDC, 12VDC, 24VDC) showing model numbers and pin designations.
Figure 1: Front view of three G5V-2 series relays (5VDC, 12VDC, 24VDC) showing model numbers and pin designations.
Bottom view of multiple G5V-2 series relays, illustrating the 8-pin configuration.
Figure 2: Bottom view of multiple G5V-2 series relays, illustrating the 8-pin configuration.
  1. Mounting: Insert the relay pins into the appropriate holes on the Printed Circuit Board (PCB) or into a compatible 8-pin relay socket. Ensure proper orientation.
  2. Wiring: Connect the coil to the appropriate DC voltage source (5V, 12V, or 24V depending on the relay model). Connect the load to the contact terminals. The G5V-2 is a DPDT relay, meaning it has two independent sets of contacts, each with a common, normally open (NO), and normally closed (NC) terminal.
  3. Power On: Once all connections are secure and verified, apply power to the circuit.

5. Operating Instructions

The OMRON G5V-2 series signal relays operate by energizing the coil to switch the contacts.

  1. Energizing the Coil: Apply the rated DC voltage (5V, 12V, or 24V, matching your specific relay model) across the coil terminals. This will create a magnetic field, causing the armature to move and switch the contacts.
  2. Contact Switching: When the coil is energized, the common (COM) contacts will switch from the normally closed (NC) position to the normally open (NO) position. When the coil is de-energized, the contacts will return to their original state (COM to NC).
  3. Monitoring Operation: You can verify operation by checking the continuity across the contact terminals with a multimeter or by observing the behavior of the connected load.

6. Maintenance

The OMRON G5V-2 series relays are generally maintenance-free. However, periodic inspection can help ensure long-term reliability.

  • Cleaning: Keep the relay and its surroundings clean and free from dust, dirt, and debris. Use a soft, dry cloth for cleaning.
  • Inspection: Periodically inspect the relay for any signs of physical damage, discoloration, or loose connections.
  • Environment: Ensure the operating environment remains within the specified temperature and humidity ranges, and free from excessive vibration or corrosive gases.
  • Storage: When not in use, store the relays in a dry, cool place, away from direct sunlight and moisture.

7. Troubleshooting

If you encounter issues with your OMRON G5V-2 series relay, consider the following:

  • Relay Not Switching:
    • Verify that the correct coil voltage (5V, 12V, or 24V) is being applied to the coil terminals.
    • Check for proper polarity if the coil is polarized (though G5V-2 is generally non-polarized, always good to check circuit design).
    • Ensure the coil is receiving sufficient current.
    • Inspect for loose or incorrect wiring connections.
    • Check if the relay itself is damaged (e.g., burnt smell, visible cracks).
  • Intermittent Operation:
    • Check for unstable power supply to the coil.
    • Ensure connections are secure and free from vibration.
    • Verify that the load current does not exceed the relay's 2A rating.
  • Contacts Stuck/Welded:
    • This can occur if the relay is switching loads exceeding its rated current or voltage, or highly inductive loads without proper arc suppression. Replace the relay and consider adding snubber circuits or using a higher-rated relay.

If the problem persists after checking these points, the relay may be faulty and require replacement.

8. User Tips

  • Always double-check your wiring against the relay's pinout diagram before applying power.
  • When designing circuits, consider adding a flyback diode across the relay coil if switching DC loads to protect driving transistors or microcontrollers from voltage spikes.
  • For inductive AC loads, consider an RC snubber network across the contacts to extend relay life.
  • Ensure the ambient temperature and humidity are within the relay's specified operating conditions for optimal performance and longevity.

9. Frequently Asked Questions (FAQ)

Q: What does 'Two open two closed' mean?
A: It refers to the contact configuration, also known as Double Pole Double Throw (DPDT) or 2 Form C. This means the relay has two independent sets of contacts, and each set has a common terminal that can switch between a normally open (NO) and a normally closed (NC) terminal.
Q: Can I use a 12VDC relay with a 5VDC power supply?
A: No, you must match the coil voltage of the relay (e.g., 5VDC, 12VDC, 24VDC) with the voltage supplied to its coil. Using an incorrect voltage will either prevent the relay from switching or damage it.
Q: What is the maximum current I can switch with this relay?
A: The maximum current rating for the contacts is 2 Amperes (2A). Exceeding this rating can damage the relay and potentially create a fire hazard.

10. Warranty and Support

For specific warranty information, please refer to the terms and conditions provided by your point of purchase or the manufacturer. In case of technical issues or support inquiries, please contact the seller or manufacturer directly.

Manufacturer: Shenzhen chengguo technology co., Itd

EU Authorized Representative: MJCM SARL France, 78 avenue des Champs Elysees Bureau 326, 33-767213611, mjcm190928@gmail.com

A user manual in PDF format is available for download: View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?