1. Introduction
The Bosean BH-4M is a professional 4-in-1 multi-gas detector designed for real-time detection of Oxygen (O2), Hydrogen Sulfide (H2S), Carbon Monoxide (CO), and Combustible Gases (LEL). This device is equipped with high-quality electrochemical sensors, providing accurate and reliable measurements. It features adjustable alarms, a clear HD color screen, and a robust design suitable for various industrial and environmental applications.
2. Safety Information
WARNING: Be aware of potential fire hazards and strictly follow the instruction manual for charging and storage. For disposal, please consult your local authority's website for further information and safely dispose of the lithium-ion battery in accordance with applicable legal requirements.
- Read this manual thoroughly before operating the device.
- Do not attempt to repair or modify the device yourself. Refer to qualified personnel for service.
- Ensure the device is used within its specified operating temperature and humidity ranges.
- Avoid exposing the device to extreme temperatures, direct sunlight, or corrosive environments.
- Keep the device clean and free from dust and debris to ensure proper sensor function.
3. Package Contents
Please check the package for the following items:
- 1 x BH-4M Multi-Gas Detector
- 1 x English User Manual
- 1 x Charging Adaptor
- 1 x Type-C USB Charging Cable
- 1 x Calibration Cover
- 1 x Metal Aluminum Box
- 1 x Certificate
- 1 x Ventilation Hose (for pump type)
- 1 x Screwdriver

Figure 3.1: Contents of the BH-4M package.
4. Product Overview
The BH-4M detector is available in two main types: Natural Diffusion and Pump Suction. The pump suction type includes a detachable gas sampling pump for active detection.

Figure 4.1: BH-4M Gas Detector with labeled components.
Key Components:
- Gas Hole: Inlet for gas detection.
- LED: Indicator light.
- Alarming Lights: Visual alarm indicators.
- Gas Sampling Pump: (Optional, for pump type) Draws gas samples.
- HD Color Screen: 2.0-inch or 2.4-inch display for clear data visualization.
- Buzzer Hole: Audio alarm output.
- Type-C Interface: For charging and data communication.
- Three Buttons: Simple and intuitive operation for navigation and settings.

Figure 4.2: BH-4M detector showing detachable pump module.
The device supports switching between Chinese and English languages for user convenience.

Figure 4.3: Language selection screen.
5. Setup
5.1. Charging the Device
Before first use, fully charge the device. Connect the provided Type-C USB charging cable to the detector and the charging adaptor to a power outlet. The device uses a 3.7V Li-battery (2500mAh). Charging time is typically less than 5 hours.
5.2. Language Settings
To change the display language:
- Navigate to the 'System Settings' menu.
- Select 'Language Settings'.
- Choose 'English' or '简体中文' (Simplified Chinese) as desired.
- Confirm your selection.
6. Operating Instructions
6.1. Basic Operation
- Turn on the power switch: Press and hold the power button until the device powers on and displays the main interface.
- Place the device in the detection area: For natural diffusion type, allow ambient air to flow freely into the gas hole. For pump suction type, attach the pump module and direct the ventilation hose to the area of interest.
- View the numerical display: The HD color screen will show real-time concentrations of O2, H2S, CO, and LEL.
6.2. Alarm Functions
The BH-4M features four alarm methods:
- Sound Alarm: An audible buzzer (up to 80dB).
- Light Flashing: Visual alerts from the LED and alarming lights.
- Vibrating Alert: Tactile feedback.
- Screen Display: Alarm messages and values shown on the screen.
High and low alarm thresholds can be adjusted through the device's menu settings. The device also supports STEL (Short-Term Exposure Limit) and TWA (Time-Weighted Average) alarm functions.
6.3. Data Storage and Communication
The device can store up to 500 alarm records or 100,000 data points. Data can be imported into a computer via the Type-C data cable for sorting and analysis using dedicated software.
7. Maintenance
7.1. Cleaning
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as they may damage the casing or screen.
7.2. Calibration
Regular calibration is essential for maintaining accuracy. Use the provided calibration cover and appropriate calibration gases. Refer to the full user manual (PDF) for detailed calibration procedures. Sensor life is approximately 2 years.
7.3. Battery Care
Recharge the battery when the low battery indicator appears. Avoid fully discharging the battery frequently to prolong its lifespan. If storing the device for an extended period, charge it to about 50% and store in a cool, dry place.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display | Low battery or device malfunction | Check the battery level and charge if necessary. Restart the device. |
| Inaccurate readings | Sensor contamination, expired calibration, or sensor damage | Clean the sensor area. Perform a calibration. If issues persist, contact support. |
| Alarms not triggering | Alarm thresholds set too high, or sensor malfunction | Check and adjust alarm settings. Verify sensor function. |
If you encounter problems not listed here or if solutions do not resolve the issue, please contact customer support.
9. Specifications
| Parameter | Details |
|---|---|
| Gas Types Detected | Oxygen (O2), Hydrogen Sulfide (H2S), Carbon Monoxide (CO), Combustible Gas (LEL/CH4) |
| Sampling Method | Pump suction or Natural diffusion |
| Detection Error | ≤±5% F.S. |
| Response Time (T90) | <30s (pump type), <60s (natural diffusion type) |
| Alarm Mode | Sound, Light, Vibration, Screen Display (quadruple alarm) |
| Operating Temperature | -20℃ to 50℃ (toxic gas), 0℃ to 40℃ (LEL) |
| Operating Humidity | <95%RH (non-condensing) |
| Display | 2.0-inch / 2.4-inch HD Color Display, resolution 320*240 |
| Power | 3.7V Li-battery (2500mAh) |
| Battery Runtime | ≥8 hours (with pump), ≥10 hours (without pump) |
| Charging Time | <5 hours |
| Charger | Type-C charging interface, 5V/1A standard charger |
| Sensor Life | 2 years |
| Data Storage | 500 alarm records / up to 100K data points |
| Data Communication | USB link to computer with software |
| System Language | Chinese and English switching |
| Dimensions (Natural Diffusion) | 145mm × 69mm × 55mm (Approx. 335g) |
| Dimensions (Pump Type) | 160mm × 69mm × 75mm (Approx. 372.5g) |
| Certification | CE |
9.1. Gas Measurement Ranges and Alarms

Figure 9.1: Gas detection ranges, alarm levels, and resolution.
10. User Tips
No specific user tips were available from provided reviews or Q&A content.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or authorized distributor. Keep your purchase receipt as proof of purchase.