1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your Din Rail Mount Voltage, Ammeter, and Hertz Meter. These modular digital display meters are designed for accurate measurement of AC voltage, current, and frequency in electrical circuits. Please read this manual thoroughly before installation and use.
2. Safety Information
- Always disconnect power before installing or servicing the device to prevent electric shock.
- Installation should be performed by qualified personnel only.
- Ensure all wiring connections are secure and correct according to the diagrams.
- This device is suitable only for AC 50-60Hz power supplies. Do not use it for measuring positive or negative sine wave circuits from generators, motors, engines, thyristor regulators, frequency converters, choppers, inverter outputs, or correction waves.
- Do not expose the device to moisture, extreme temperatures, or corrosive environments.
3. Package Contents
- Din Rail Mount Digital Meter (Voltmeter, Ammeter, Hertz Meter, or combined unit)
- Current Transformer (CT) for Ammeter models (approx. 1m cable length)
- Instruction Manual (this document)
4. Product Overview
The FH66 series meters are compact, modular devices designed for DIN rail mounting. They feature a clear LED digital display for easy reading of measurements.
4.1. Available Models
- Voltmeter (FH66-V): Measures AC voltage. Available in single, dual, or three-phase configurations.
- Ammeter (FH66-A): Measures AC current. Requires an external Current Transformer (CT). Available in single, dual, or three-phase configurations.
- Hertz Meter (FH66-H): Measures AC frequency.
- Combined Units (e.g., FH66-VA, FH66-VH, FH66-AH, FH66-VAH): Measure combinations of voltage, current, and frequency.
4.2. Physical Dimensions
The meter is designed for standard DIN rail mounting.

4.3. Current Transformer (CT) for Ammeter Models
A current transformer is supplied with ammeter models for current measurement.

5. Specifications
| Feature | Specification |
|---|---|
| Brand Name | DIANQI |
| Model Number | FH66-VAH (Voltmeter, Ammeter, Hertz Meter) |
| Display Type | Digital Only (LED Red) |
| Rated Operating Voltage Range | AC80V - 500V |
| Current Measurement Range | 0 - 100A |
| Frequency Compatibility Range | 1 - 99Hz |
| Rated Frequency | 50-60Hz |
| Accuracy Class | Normal (Error ± 2%) |
| Installation Method | DIN35MM Standard Guide Rail |
| Environmental Temperature | -25°C to +55°C |
| Power Supply | AC |
| Input Circuit Power | <2VA |
| Sampling Rate | Approximately once per second |
| Battery Included | No |
| Certification | NONE |
| Origin | Mainland China |
6. Setup and Installation
Ensure power is disconnected before proceeding with installation. Mount the meter onto a standard 35mm DIN rail.
6.1. Voltmeter Wiring (FH66-V)

- Single Phase Voltmeter: Connect contacts 1 and 2 to the phase (L) and neutral (N) wires respectively.
- Dual Phase Voltmeter: Connect contacts 1 and 2 to the first phase (L1) and neutral (N1) wires. Connect contacts 3 and 4 to the second phase (L2) and neutral (N2) wires.
- Three Phase Voltmeter: Contacts 1 and 2 are connected to the V1~ power display. Contacts 3 and 4 are connected to the V2~ power display. Contacts 5 and 6 are connected to the V3~ power display.
6.2. Ammeter Wiring (FH66-A)

- Single Phase Ammeter: Connect contacts 1 and 2 to the live and neutral wires. Connect contacts 3 and 4 to the current transformer input, which is inserted around the load wire.
- Dual Phase Ammeter: Connect contacts 1 and 2 to the phase and neutral wires. Connect contacts 3 and 4 to the first current transformer, and contacts 5 and 6 to the second current transformer.
- Three Phase Ammeter: Connect contacts 1 and 2 to the phase and neutral wires. Connect contacts 3 and 4 to the first current transformer, 5 and 6 to the second, and 7 and 8 to the third current transformer.
6.3. Hertz Meter Wiring (FH66-H)
For single-phase Hertz meters, connect contacts 1 and 2 to the live and neutral wires of the circuit where frequency is to be measured.
7. Operating Instructions
Once correctly wired and power is supplied, the meter will automatically display the measured values on its LED screen. No further configuration is typically required.
- Voltmeter: Displays voltage in Volts (V).
- Ammeter: Displays current in Amperes (A).
- Hertz Meter: Displays frequency in Hertz (Hz).
8. Maintenance
- Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
- Do not use abrasive cleaners or solvents.
- Regularly check wiring connections for tightness and signs of wear.
- No user-serviceable parts inside. Do not attempt to open or repair the device.
9. Troubleshooting
- No Display: Check if power is supplied to the meter terminals (1 and 2). Ensure wiring is correct and secure.
- Incorrect Readings: Verify that the meter is connected to an AC 50-60Hz supply. For ammeters, ensure the CT is correctly installed around the load wire and connected to the meter. Check for loose connections.
- Flickering Display: May indicate unstable power supply or loose connections.
10. User Tips
- When installing ammeters, ensure the current transformer (CT) is properly oriented around the live wire of the load for accurate readings.
- For multi-phase systems, double-check that each phase's voltage or current input corresponds to the correct display segment on the meter.
- While the figures are clear, some users note they can be a bit small; ensure good lighting for optimal readability.
11. Warranty and Support
Please refer to your purchase documentation for specific warranty terms and conditions. For technical support or inquiries, contact your vendor or the manufacturer.