RuoShui 10N-500N

Contents

RuoShui Digital Force Gauge User Manual

Models: 10N, 50N, 100N, 200N, 300N, 500N

1. Introduction

This RuoShui Digital Force Gauge is a high-performance, compact, and user-friendly instrument designed for precise push and pull force testing. It offers excellent value and portability for various applications.

2. Key Features

  • Digital display for easy and accurate readings.
  • Lightweight and compact design for convenient portability.
  • Selectable units: Newtons (N), Kilograms (Kg), and Pounds (Lb).
  • Built-in safety features: Short circuit protection, leakage protection, and overload protection.
  • Low battery indicator and automatic shutdown after 10 minutes of inactivity to conserve power.
  • Powered by a 3.7V lithium battery.
  • Peak hold function to capture maximum force values.
  • Backlit display for visibility in various lighting conditions.
  • One-key zero function for quick calibration.
  • Reset function to restore factory settings.
RuoShui Digital Force Gauge with features highlighted
Figure 1: RuoShui Digital Force Gauge showcasing its main features and included accessories.
500N model features overview
Figure 2: Overview of the 500N model's comprehensive features, including peak hold, rechargeable function, and various protections.

3. Product Overview and Components

Familiarize yourself with the main components and controls of your digital force gauge:

Labeled diagram of the force gauge components
Figure 3: Detailed diagram of the force gauge, identifying its key parts and controls.
  1. Screw: Attachment point for various fixtures.
  2. LCD: Digital display screen for readings and settings.
  3. Power Indicator: Light indicating power status.
  4. OFF/ON Button: Powers the device on and off.
  5. UNIT Button: Toggles between measurement units (N, Kg, Lb).
  6. ZERO Button: Resets the current reading to zero.
  7. SET Button: Enters peak hold mode and accesses setting options.
  8. Power Jack (5V 1A): Input for charging the device.
  9. Reset Button: Small button on the side to perform a hard reset (requires a pointed object).
Force gauge with various attachments
Figure 4: The digital force gauge shown with its standard set of interchangeable fixtures, including a hook, flat head, cone head, V-groove, and an extension rod.

4. Setup

4.1 Initial Charging

Before first use, or if the instrument's battery is low, charge the device for 4-6 hours using the provided charger. The power jack is labeled 5V 1A.

4.2 Attaching Fixtures

Select the appropriate test fixture (e.g., hook, flat head, cone head) for your application. Screw the chosen fixture securely onto the threaded shaft at the top of the force gauge.

Force gauge with multiple fixture options
Figure 5: Close-up view of the force gauge display and the multiple fixture options available for different testing needs.

5. Operating Instructions

5.1 Power On/Off

  • Press the OFF/ON button to power on the device. The measurement interface will appear.
  • Press the OFF/ON button again to power off the device.

5.2 Zero Function

  • With no load applied, press the ZERO button to reset the current reading on the screen to zero.

5.3 Unit Conversion

  • Press the UNIT button to cycle through the available measurement units: Newtons (N), Kilograms (Kg), and Pounds (Lb).

5.4 Peak Hold Mode

  • From the measurement interface, press the SET button to enter "Peak Hold" mode. In this mode, the instrument records and displays the maximum force value measured during a testing period.

5.5 Setting Parameters

To access the setting menu:

  1. With the device powered on, press and hold the SET button for 4-5 seconds, then release. The display will show "HIDT" (High Limit Setting).
  2. Continuously press the UNIT button to cycle through other settings: "LODT" (Low Limit Setting), "L.SET" (Minimum Peak Value Save), "OFFT" (Auto-off Time), "G.SET" (Gravity Acceleration), "BAC.S" (Backlight Setting), and "R.SET" (Restore Factory Settings).

5.5.1 HIDT (High Limit Setting)

Sets the upper limit for the test value. The default is 99% of the full range. If the measured value exceeds this limit, the instrument will alarm. Use UNIT and ZERO buttons to adjust the value. Press SET to save and return to the setting menu.

5.5.2 LODT (Low Limit Setting)

Sets the lower limit for the test value. The default is 0. If the measured value falls below this limit, the instrument will alarm. Adjust and save similarly to HIDT.

5.5.3 L.SET (Minimum Peak Value Save)

In peak hold mode, if the current peak value is less than this set value, it will not be saved.

5.5.4 OFFT (Auto-off Time)

Set the automatic shutdown time from 1 to 9999 minutes, or set to "00" for no automatic shutdown. The default is 10 minutes. Press SET to confirm.

5.5.5 G.SET (Gravity Acceleration)

Users can set the gravity acceleration value according to their local region. The default value is 9.800.

5.5.6 BAC.S (Backlight Setting)

Use the UNIT button to select "YES" to enable backlight or "NO" to disable it. Press SET to save.

5.5.7 R.SET (Restore Factory Settings)

To restore the instrument to factory default settings, press the SET button when "R.SET" is displayed. The machine will shut down. Power it on again to use.

5.6 Basic Measurement Procedure

  1. Power on the device.
  2. Attach the appropriate test fixture.
  3. Hold the force gauge firmly or mount it on a suitable test stand.
  4. Apply the force to be measured, ensuring the force is applied in a straight line with the push-pull rod for accurate readings.
  5. Read the force value on the digital display.
  6. After testing, remove the load, power off the device, and detach the fixtures.

6. Maintenance

6.1 Cleaning

Clean the instrument with a soft cloth. If necessary, dampen the cloth with water and a mild detergent, wring it dry, and then wipe the instrument. Do not use volatile chemicals such as thinners or alcohol, as they may damage the surface.

6.2 Storage

Store the instrument within the specified temperature and humidity range to prevent malfunction. Keep all accessories clean and organized in their storage box for future use.

6.3 Battery Care

The device is powered by a 3.7V lithium battery. Ensure regular charging to maintain battery health. The instrument features low battery indication and various protections (short circuit, leakage, overload) to prolong battery life and ensure safe operation.

7. Troubleshooting

Symptom Cause Solution
No display when powered on Battery depleted Recharge the battery
Inaccurate test values Excessive error Return to factory for calibration
Instrument freezes/crashes No response to any button Press the reset button with a pointed object
Overload alarm (beeping) Measured value exceeds 100% of full range Quickly remove or reduce the applied load. If it exceeds 120%, the instrument may be damaged.

7.1 Resolving Instrument Freezing

If the instrument unexpectedly freezes, use a small, pointed object (like a pin) to press the reset button located on the side of the device. This will perform a hard reset and power off the unit. You can then power it on again.

8. Specifications

Parameter Details
Model Number 10N-500N RuoShui
Max Load (N) 2N, 3N, 5N, 10N, 20N, 30N, 50N, 100N, 200N, 300N, 500N (depending on model)
Max Load (Kg) 0.2kg, 0.3kg, 0.5kg, 1kg, 2kg, 3kg, 5kg, 10kg, 20kg, 30kg, 50kg (depending on model)
Max Load (Lb) 0.45Lb, 0.65Lb, 1.1Lb, 2.2Lb, 4.5Lb, 6.5Lb, 11Lb, 22Lb, 45Lb, 65Lb, 110Lb (depending on model)
Load Division Value (N) 0.001N (for 2N-5N), 0.01N (for 10N-50N), 0.1N (for 100N-500N)
Load Division Value (Kg) 0.001kg (for 2N-5N), 0.001kg (for 10N-50N), 0.01kg (for 100N-500N)
Load Division Value (Lb) 0.001Lb (for 2N-5N), 0.001Lb (for 10N-50N), 0.01Lb (for 100N-500N)
Sensor Structure Built-in
Accuracy ±0.5%
Power Supply 3.7V Lithium Battery
Charging Time 4-6 hours
Continuous Use Time Approx. 15 hours
Battery Life ≥300 cycles
Charger Input AC 220V 50HZ
Charger Output DC 5V 1000mA
Operating Temperature 5°C ~ 35°C
Storage Temperature -10°C ~ 60°C
Relative Humidity 15% ~ 80%RH
Working Environment No vibration source or corrosive media
Display Type DIGITAL
Certification CE

8.1 Dimensions

Dimensions of the digital force gauge
Figure 6: Front, back, and side views with dimensions (in millimeters) of the digital force gauge.

The dimensions are approximately: Length 147mm, Width 72mm, Thickness 33.75mm. The screw thread is M6.

9. User Tips

  • For consistent results, always ensure the force is applied smoothly and directly along the axis of the sensor.
  • Utilize the Peak Hold function for destructive testing or when measuring transient forces to capture the maximum value accurately.
  • Regularly check the battery level, especially before critical measurements, to avoid interruptions.
  • Keep the various fixtures organized and clean to ensure they are ready for immediate use and to prevent damage.

10. Warranty and Support

For technical support, warranty claims, or service, please contact the manufacturer or seller using the information below. It is recommended to refer to the full user manual PDF for detailed information.

Manufacturer/Seller Contact Information:

  • Company: Shenzhen Yisheng Victor Technology Co., LTD
  • Address: 16th Floor, D Block, Tairan Building, Tairan 6th Road, Futian District, Shenzhen City
  • Phone: 4000 900 306, (0755) 82425035, 82425036
  • Fax: (0755) 82268753
  • Website: www.china-victor.com
  • Email: victor@china-victor.com

A detailed user manual in PDF format is available for download: RuoShui Digital Force Gauge User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.