MYOSLIM X5 / X5 Pro

Contents

MYOSLIM X5/X5 Pro-AI Skin Image Analyzer User Manual

Digital AI Skin Image Measurement System - Decipher the Secret of Deep Skin

1. Introduction

Thank you for choosing the MYOSLIM X5/X5 Pro-AI Skin Image Analyzer. This product integrates a high-precision multispectral imaging system and an AI deep learning algorithm to conduct multidimensional analysis of skin tissue and support various detections.

Key Features:

  • High-Precision Multispectral Imaging: Utilizes advanced imaging for detailed skin analysis.
  • AI Deep Learning Algorithm: Provides accurate and reliable data for skin conditions.
  • Comprehensive Skin Analysis: Detects various skin physiological indexes and pathological features.
  • Scalp and Hair Follicle Evaluation: Offers insights into scalp microcirculation and hair morphology (X5 model does not include all hair-related functions).
  • Health Management: Supports face and weight (wF) and sleep and face (SF) health management.
  • Professional Application: Ideal for skin management institutions, health management centers, and scalp health fields, providing quantitative diagnostic basis for skin intervention programs.
MYOSLIM X5/X5 Pro-AI Skin Image Analyzer main unit and screen

Figure 1: MYOSLIM X5/X5 Pro-AI Skin Image Analyzer Overview

2. Product List

Upon receiving the product, carefully open the packaging and ensure all components are present:

ItemQuantity
Tablet Stand Base Bracket1
Instruction Manual1
Micro-instrument Base1
Micro-instrument (Handheld Probe)1
USB Cable1
Host Power Cable1
Tablet Power Adapter1
Apron (Neck blackout cloth)1
Screwdriver and Screws1 set
Main Unit (Host)1
Tablet (Display)1
Certificate of Qualification1
Contents of the MYOSLIM X5/X5 Pro-AI Skin Image Analyzer package

Figure 2: Product Components

3. Setup Instructions

Please read this manual thoroughly before installing and using the X5/X5 Pro-AI Skin Image Analyzer.

Video 1: Unboxing and Installation Guide

3.1. Tablet Stand Base Installation

  1. Place the tablet stand over the stand base slot.
  2. Rotate the stand base lock ring 180 degrees to secure it.

3.2. Bracket and Tablet Installation

  1. Secure the assembled base bracket to the back of the tablet.
  2. Sequentially tighten the four screws using the provided screwdriver.

3.3. Tablet Accessories Installation

  1. Insert the tablet power cable, USB connection cable, and the USB interface of the micro moisture meter sequentially at the bottom of the tablet stand.
  2. During operation, you may rotate the tablet by 90 degrees for optimal viewing.

3.4. Host Hardware Installation

  1. Insert the host power cord and the other end of the USB cable into the back of the host unit.
Diagram showing the components and connection points of the host machine and handheld probe

Figure 3: Product Introduction and Connections

Diagram showing the various ports on the display screen: USB data interface, HDMI data interface, Network cable interface, Power cord interface

Figure 4: Display Screen Ports

3.5. Power On

  1. Connect the host power cord and the tablet charger to an energized outlet respectively.
  2. Press the power button at the bottom of the host. The illumination of the indicator light signifies that the device is turned on.
  3. To turn off, simply click the power button again or unplug the power cord from the outlet.

3.6. Tablet Power Switch

Swipe up from the bottom of any screen to find the power button, click to select, and then choose shutdown to turn off the device.

4. Operating Instructions

4.1. App Usage - Network Connections

  1. After the device is turned on, a network connection prompt will automatically pop up.
  2. Click "Confirm" to select the appropriate network and then enter the password to connect to the network.
  3. Once connected, click the return button in the upper right corner to return to the main interface.

4.2. App Usage - Account Registration & Login

  1. Upon first login, click the register button to enter the registration page.
  2. Fill in the required fields: username, phone number, verification code, password, and password confirmation.
  3. After completing the form, click register to be redirected to the login interface where you can log in.
  4. Users with existing accounts can log in directly to use the service.
  5. Note: Registered accounts are default management accounts that allow access to the backend for product entry, device management, and personnel management.

4.3. App Usage - Customer Filing

  1. From the homepage, you can enter four types of detection mode windows.
  2. Click on "Start Skin Test" to enter the customer profile creation interface.
  3. Click on "Add New Customer" at the bottom right corner.
  4. Fill in the customer information as required, and click "OK" to enter the photo-taking interface after completion.
  5. To batch create new customer profiles, select "Customer Management" from the bottom navigation bar on the main interface, and then choose "Add New Customer".

4.4. App Usage - Skin Measurement and Photographing

  1. Upon entering the camera page, click the top right corner to select the face you need to photograph (left face, right face, front face).
  2. Follow the voice prompts to position yourself correctly, close your eyes, and click the photo button to start taking photos.
  3. Once all required faces are photographed, submit and upload for analysis.
  4. Note: The domestic trade version does not require selection of skin tone; the real and virtual contrast is for position comparison of customers who have already been photographed.

4.5. App Usage - Moisture Detection

  1. To access the moisture analysis page from the skin analysis page, click on the start detection button.
  2. Follow the prompts to place the moisture meter flat against the corresponding area of the facial skin.
  3. Click the capture button on the moisture meter to obtain the moisture value.
  4. After completing the detection of all four areas, click submit to enter the moisture analysis page.

4.6. App Usage - Report Sharing and Printing

  1. On the upper right corner of the comprehensive report page, click the share button to choose between obtaining the report via QR code or sending the report via email.
  2. You can also select the print button to print the report.

4.7. App Usage - Microscopic Scalp Detection

  1. Click on the Microscopic/Skin Inspection to enter the photo-taking mode.
  2. Select the area you need to photograph, then place the bottom of the handheld microscope flat against the area you need to capture.
  3. Click the photo-taking button at the bottom of the screen or the photo-taking button on the handle to take the picture.
  4. Wait for the three sets of light sources to complete the shooting, then proceed to the next area for photographing.
  5. Note: The X5 model does not have permission to use the microscopic detection feature.
Nine spectral images for comprehensive skin analysis

Figure 5: Nine Spectral Images for Skin Analysis

Images showing acne detection and analysis results

Figure 6: Acne Detection and Analysis

Images illustrating sensitive skin and pigmentation analysis

Figure 7: Sensitive Skin and Pigmentation Analysis

Images demonstrating skin aging detection, including wrinkles and collagen fibers

Figure 8: Skin Aging Detection

Images showing detection of fluorescent agents on skin

Figure 9: Fluorescent Agent Detection

Images illustrating HD scalp detection for hair density, thickness, and grease

Figure 10: HD Scalp Detection

5. Maintenance and Care

⚠️ Warning:

Maintenance work on this instrument should be carried out by personnel with after-sales qualifications or repair personnel familiar with this instrument. Before maintaining this instrument, the power should be cut off and the power cord should be pulled out of the power outlet. Performing maintenance on the equipment while it is still powered could result in personal injury and damage to the instrument.

ℹ️ Note:

The entire cleaning process should prohibit the cleaning solution from flowing into the instrument to prevent electrical leakage or corrosion of the USB socket, which could lead to poor contact.

General Care Guidelines:

  1. Avoid Contaminants: Prevent the inflow of harmful gases and corrosive liquids into the instrument. Water is strictly prohibited from entering the main unit to prevent a decrease in insulation performance, which could lead to electric leakage and personal injury.
  2. Storage: The entire machine should be used in a dry and ventilated area, and should be covered with a cloth when not in use.
  3. Handle with Care: The instrument is prohibited from collision, as it contains precision electronic circuits. Please do not attempt to open it without authorization.
  4. Cleaning: The instrument should always be kept clean. A soft, semi-dry cotton ball should be used for cleaning. Cleaning should be done with 75% alcohol. Organic solvents such as acetone are prohibited. During cleaning, the cleaning solution should not seep into the instrument, and high-temperature sterilization should be avoided.

6. Troubleshooting & FAQ

ProblemSolution
Moisture cannot be detected.Ensure the micro moisture meter USB cable is connected to the tablet.
Wf/sf management fails to report.First, enter the corresponding weight or sleep duration data as prompted by the page.
Sunscreen testing will not be conducted.Sunscreen testing requires applying sunscreen products and then taking photos.
Case entry point not found.Look on the right side of each detection indicator analysis page.
The brush tool function cannot find the save image option.This option is located at the very bottom of the comprehensive skin analysis report.
Cannot find the language settings window.Navigate to the navigation bar at the bottom of the home page, then select 'General settings' of the 'Management Center'.
How to enter products.Log in to the web page on the computer end.

7. Specifications

Electrical Parameters:

ParameterValue
Input100~240VAC 50/60HZ
Frequency50/60HZ
Impedance50Ω
Output Power0-30W RATED CURRENT: 1A
Power Supply Voltage100~240VAC

The power cord used for this instrument complies with national safety standards. It is imperative to use wall outlets or power strips with safety-certified national standard wires for operational safety.

Other Specifications:

  • Material: Resin
  • Brand Name: MYOSLIM
  • Origin: Mainland China
  • Certification: CE, RoHS
  • High-concerned chemical: None
  • Power Type: Electric
  • Objective: Face Hair
  • Technology: Industrial Grade ABS PC, Intelligent Skin Analyzer System
  • Pixels: 36 Million
  • Method of Light Bleet: Invisible Light Shield
  • Gross Weight (Solo): 19.000 KG
  • Display Size: 21.5 inches
  • Features: Assess sebum levels, Skin wrinkle analysis, Pigmentation analysis, Hair follicle detection, Hair Analysis, Acne analysis
  • After-sales Service Provided: Online support, Free spare parts, Video technical support

8. Warranty & Support

Warranty Coverage:

  1. The host comes with a one-year free warranty and offers long-term after-sales repair services.
  2. During the warranty period, users are entitled to unified after-sales service and the policy of replacing warranty parts.
  3. During maintenance, a valid warranty certificate for the purchase of the machine must be presented. The warranty period is valid from the date of the instrument's factory shipment.
  4. After repair, if the same component and the same failure phenomenon reappear, free maintenance is provided within 90 days.
  5. Parts repaired or replaced during the warranty period belong to the after-sales maintenance network, while parts repaired or replaced after the warranty period belong to the user.
  6. Additional services and non-factory configured gifts promised by each regional distributor are to be maintained by the distributor themselves.

No Warranty Coverage (Paid Repairs Apply):

  1. X5/X5 Pro-AI Skin Image Analyzer accessories and free gifts.
  2. Damage caused by the user's improper handling, use, maintenance, and storage.
  3. Damage caused by using voltage lower than 100 volts or higher than 240 volts.
  4. Damage caused by not using, maintaining, and maintaining the product in accordance with the instructions in the product manual.
  5. Disassembly or repair by non-related after-sales service personnel.
  6. Using accessories and products provided by non-related after-sales service personnel without company permission, resulting in instrument damage or other issues.
  7. Damage due to force majeure (such as lightning, fire, earthquake, flood, and other natural disasters).
  8. The product is past the warranty period.
  9. The model or number recorded on the invoice or warranty card does not match the actual product.

In the above cases, after-sales service personnel will implement paid repairs, which include repair fees, parts fees, and on-site service fees. The specific fee standards are within the scope permitted by the relevant departments.

For detailed warranty information, please refer to the User Manual (PDF).

9. User Tips

  • Easy Setup: The machine is designed for simple installation. Follow the video guide for a smooth setup process.
  • Intuitive Operation: The interface is user-friendly, making it easy for new users to learn and operate without extensive training.
  • Comprehensive Skin Insights: The device captures clear images and highlights skin issues not visible to the naked eye, providing valuable data for skincare routines.
  • Comfortable Experience: During treatments, users often report feeling warmth and light pressure, finding the experience quite relaxing.
  • Professional Credibility: The clear and objective data provided by the analyzer can help build trust with clients by offering reliable skincare solutions.
  • Support: If you have any questions or encounter issues, please contact customer support for assistance.

© 2024 MYOSLIM. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.