GEYA 4P VA5 Overvoltage & Undervoltage Protector Instruction Manual

Universal Circuit Safety Device for AC220V/380V Home & Industrial Applications

1. Introduction and Overview

The GEYA 4P VA5 is an advanced overvoltage and undervoltage protector designed to safeguard electrical circuits in both home and industrial environments. This device provides comprehensive protection against voltage fluctuations, including overvoltage and undervoltage conditions, as well as overcurrent and phase sequence errors in three-phase systems. Its intelligent design ensures reliable operation and enhanced safety for connected equipment.

Image showing various application scenarios for the GEYA 4P VA5 protector, including shopping malls, industrial electricity, collective dormitories, and household electricity.
Figure 1: Wide Application Scenarios for the GEYA 4P VA5 Protector.

The GEYA 4P VA5 protector is suitable for diverse applications such as shopping malls, industrial electrical systems, collective dormitories, and general household electricity, ensuring broad utility and safety.

2. Safety Information

Please read and understand all safety instructions before installing, operating, or maintaining this device. Failure to follow these instructions may result in serious injury or property damage.

  • Qualified Professionals Only: This equipment must be installed by qualified electrical professionals.
  • Power Disconnection: Before operating or performing any work on the device, ensure all power supplies are disconnected. Do not touch any terminals when the power supply is connected.
  • Proper Connections: Always verify that all terminals are properly connected according to the wiring diagram.
  • No Disassembly or Repair: Do not disassemble or attempt to repair the equipment. Any unauthorized modification or repair will void the warranty and may lead to hazardous conditions. The manufacturer and seller are not responsible for issues arising from unauthorized tampering.
  • Environmental Conditions: Do not use the equipment in environments where it may be corroded by gas, exposed to strong sunlight, or heavy rain. Ensure the operating environment adheres to the specified ambient temperature and humidity ranges.

3. Product Features

The GEYA 4P VA5 protector offers a range of features to ensure comprehensive circuit protection:

  • Overvoltage Protection: Automatically disconnects power when voltage exceeds a set limit.
  • Undervoltage Protection: Automatically disconnects power when voltage drops below a set limit.
  • Overcurrent Protection: Monitors and protects against excessive current draw.
  • Phase Sequence Error Indication: Detects and indicates incorrect phase sequencing in three-phase systems.
  • Adjustable Parameters: User-configurable settings for overvoltage, undervoltage, overcurrent, and delay times.
  • Digital Display: Real-time display of voltage (V) and current (A) for each phase (L1, L2, L3).
  • Fault Indication: LEDs and display messages provide clear indications of fault conditions.
  • Automatic Reset: Features an automatic reset function after certain fault conditions are cleared.
  • Manual Reset: Option for manual reset in specific fault scenarios, such as continuous overcurrent.
  • Compact Design: Moulded case type, suitable for DIN rail mounting.

4. Technical Specifications

The following table details the technical specifications of the GEYA 4P VA5 Overvoltage & Undervoltage Protector:

ParameterSpecification
Supply TerminalsN, L1, L2, L3
Rated Supply VoltageAC380V
Operating Voltage RangeAC120V-300V
Rated Frequency40/50/60/70Hz
Overvoltage Protection Value (P-3)230V-300V
Overvoltage Recovery Value (P-4)225V-295V
Undervoltage Protection Value (P-5)170V-210V
Undervoltage Recovery Value (P-6)175V-215V
Voltage Hysteresis5V
Overvoltage Trip Delay0.5s
Voltage Accuracy<1% (On the whole spectrum)
Max. Operating Phase Voltage350V
Max. Operating Current63A / 100A (model dependent)
Altitude≤2000m
Permissible Relative Humidity≤95% at 40°C (without condensation)
Ambient Temperature-25°C ~ +55°C
Storage Temperature-25°C ~ +55°C
Asymmetric Delay10s
Rated Insulation Voltage450V
Output Contact3NO
Electrical Life105
Mechanical Life106
Protection ClassIP20
Pollution Degree3
Product dimensions diagram for GEYA 4P VA5 protector, showing measurements of 90mm width, 97mm height, 70mm depth, 46mm front panel height, and 35mm side depth.
Figure 2: Product Dimensions.

The device measures 90mm in width, 97mm in height, and 70mm in depth. The front panel has a height of 46mm, and the side depth is 35mm.

5. Installation and Setup

5.1 Wiring Diagram

The GEYA 4P VA5 protector is designed for three-phase systems. Ensure proper connection of the Neutral (N) and Live (L1, L2, L3) lines from the power source to the corresponding input terminals, and then to the load terminals.

Simplified wiring diagram for GEYA 4P VA5 protector, illustrating connections for power (N, L1, L2, L3) and load.
Figure 3: Basic Wiring Diagram.

Connect the incoming power lines (N, L1, L2, L3) to the top terminals and the outgoing load lines to the bottom terminals, matching the phase labels.

Detailed operational diagrams for GEYA 4P VA5 protector, including display panel indicators, electrical schematic, product status logic, reset/start delay, phase sequence error, continuous overcurrent indication, and setup menu parameters P-1 to P-15.
Figure 4: Detailed Wiring Diagram and Electrical Symbol.

The detailed wiring diagram shows the internal connections and the electrical symbol for the protector. Ensure all connections are secure and correctly phased.

5.2 Setup Menu Parameters

The device features a setup menu for configuring various protection parameters. Use the 'SET' button to enter the menu and the up/down arrow buttons to navigate and adjust values. The 'SET' button also acts as a hand switch and menu key.

Technical specifications table and detailed setup menu (P-1 to P-15) for GEYA 4P VA5 overvoltage and undervoltage protector.
Figure 5: Setup Menu and Technical Data.

The setup menu allows for precise configuration of protection thresholds and delays. Refer to the table below for parameter descriptions.

Parameter CodeDescriptionDefault/Range
P-1Power-on delay time5s (1-600s)
P-2Protection recovery delay30s (1-600s)
P-3Overvoltage protection value270V (230V-300V)
P-4Overvoltage recovery value265V (225V-295V)
P-5Undervoltage protection value170V (170V-210V)
P-6Undervoltage recovery value175V (175V-215V)
P-7Voltage protection action delay0.5s (0.1s-10s)
P-8Three-phase voltage imbalance value50V (20V-100V)
P-9Three-phase voltage imbalance Recovery value20V (5V-95V)
P-10Three-phase voltage calibration0 (-9.5V-9.5V)
P-11Phase-sequence switchon/off
P-12Overcurrent protection value63A (1-63A) / 100A (1-100A)
P-13Overcurrent protection Action time0.5s (0.1s-10s)
P-14Continuous overcurrent protect frequencyOFF (0-20)
P-15Three-phase current error calibration0 (-9.5A-9.5A)

6. Operation

6.1 Display Panel

The front panel features a digital display and control buttons. The display shows real-time voltage (V) and current (A) for each phase (L1, L2, L3). The 'SET' button is used for menu navigation and parameter adjustment, while the up/down arrows modify values. A power button is also present.

Detailed operational diagrams for GEYA 4P VA5 protector, including display panel indicators, electrical schematic, product status logic, reset/start delay, phase sequence error, continuous overcurrent indication, and setup menu parameters P-1 to P-15.
Figure 6: Display Panel and Controls.

The display panel provides visual feedback on system status and allows for interaction with the device settings.

6.2 Product Status and Fault Indication

  • Normal Operation: When the relay is operating normally, the operating voltage and current values will be displayed on the screen.
  • Voltage/Current Fault: If a voltage or current fault is detected, the output relay turns off, and the fault indication LED lights up.
  • Voltage Failure Recovery: If the input voltage returns to within acceptable hysteresis limits after a voltage failure, the relay will automatically reset after counting the reset/start delay. The fault indicator light will turn off, and the working voltage and current values will flash on the screen.
  • Reset/Start Delay Display: During a voltage operating value display, if a fault occurs, the display will show "SEC" and the countdown for the delay. After the delay, the output relay closes, and the system returns to normal operation.
  • Phase Sequence Error Indication: If a phase fault occurs (e.g., L1-L2-L3 is disconnected from the power supply output), the display will indicate the error.
  • Continuous Overcurrent Faults: If a continuous overcurrent fault is detected, the display will show "OFF". To clear this fault, a manual reset is required.

7. Maintenance

The GEYA 4P VA5 protector is designed for minimal maintenance. However, regular checks can ensure its longevity and optimal performance:

  • Visual Inspection: Periodically inspect the device for any signs of physical damage, loose connections, or discoloration.
  • Environmental Check: Ensure the operating environment remains within the specified temperature and humidity ranges and is free from corrosive gases, strong sunlight, or excessive moisture.
  • Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
  • No User Serviceable Parts: As stated in the safety information, there are no user-serviceable parts inside. Do not attempt to open or repair the device.

8. Troubleshooting

This section provides guidance on common issues and their resolutions:

ProblemIndicationPossible CauseSolution
Device not operating, fault LED on.Fault indication LED lights up, output relay off.Overvoltage, undervoltage, or overcurrent fault detected.Check power supply voltage and load current. The device should automatically reset once conditions return to normal after the recovery delay.
Display shows "SEC" and a countdown."SEC" displayed with a decreasing number.Device is in reset/start delay mode after a fault or power-on.This is normal operation. Wait for the countdown to complete. The device will resume normal operation.
Display shows "OFF" for current."OFF" displayed for current readings.Continuous overcurrent fault detected.Reduce the load or check for short circuits. Manually reset the device using the appropriate button (refer to display panel controls).
Phase sequence error.Indication of L1, L2, L3 disconnection.Incorrect phase connection or loss of a phase.Verify the phase connections from the power supply. Ensure all phases are present and correctly wired.

9. Warranty and Support

GEYA products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please contact your authorized GEYA distributor or the seller directly. Ensure you have your product model (4P VA5) and purchase details available when seeking support.

Manufacturer: GEYA

Store: GEYA Factory Store

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.