SWEVY SW1018A

Contents

SWEVY SW1018A Flexible Coil Clamp Meter User Manual

Model: SW-1018A

1. Introduction

The SWEVY SW1018A is a digital flexible current clamp meter designed for precise measurement of AC/DC voltage, AC current, and resistance. Its flexible coil design allows for measurements in narrow and densely wired environments. This manual provides essential information for the safe and effective operation of your device.

SWEVY SW1018A Flexible Coil Clamp Meter with key features listed

Figure 1: SWEVY SW1018A Flexible Coil Clamp Meter highlighting its 150mm coil diameter, 0mA-9999A current range, AC/DC voltage, AC current, resistance test capabilities, and 600 data storage groups.

2. Safety Information

WARNING: High voltage, extremely dangerous! Must be operated by trained and authorized personnel. The operator must strictly follow the safety rules, otherwise there would be danger of electric shock, causing personal injury or injury accident.

DANGER: Cannot be used to measure voltage lines exceeding 1000V, otherwise there would be danger of electric shock, causing personal injury or injury accident.

  • The current exceeding the limit indicated on the instrument must not be measured to avoid damaging the instrument.
  • The wire should be placed as close as possible to the center of the clamp.
  • When measuring voltage, pay attention to connecting the measurement leads and avoid short-circuiting the measured circuit.
  • After the voltage measurement is completed, the measuring wire should be removed from the measured conductor first, and then pulled out from the instrument to avoid electric shock.

3. Specifications

FeatureSpecification
Model NumberSW1018A
Dimensions165*105*35mm
Weight220g
Display TypeDigital Only
Operating Temperature-10~40℃
Storage Temperature-10~60℃
Measuring Current Range0mA-9999A
Current Resolution1mA
Measuring Voltage RangeDC 0~1000V/AC 0~750V
Voltage Resolution0.1V
Measuring Resistance Range0-2000Ω
Coil ID (Inner Diameter)150mm
Sampling Speed1s
Data Storage600 groups
Battery IncludedNo
DIY SuppliesElectrical
CertificationCE, RoHS

4. Setup

4.1. Battery Installation

The SWEVY SW1018A does not include batteries. Please ensure you have the correct type and install them before first use. Refer to the battery compartment for polarity markings.

4.2. Start-up and Shutdown

To start the device, press the Power button icon key. The LCD will display and enter normal test mode. To shut down, press the Power button icon button again. The instrument will automatically shut down after approximately 10 minutes of inactivity.

5. Operating Instructions

5.1. Test Mode Selection

Press the A/V/Ω button to cycle through the three measurement modes: Current (A), Voltage (V), and Resistance (Ω). Upon powering on, the meter automatically defaults to the current testing mode (A).

5.2. Current Measurement

Important Safety Note: Always refer to the safety warnings in Section 2 before performing any measurements.

  1. Start the meter. It will automatically enter current test mode. If not, press the A/V/Ω button to switch to current test mode (A).
  2. Rotate the lock catch on the flexible coil according to the "OPEN" direction.
  3. Unscrew the flexible coil lock catch.
  4. Clamp the measured wire with the flexible coil clamp.
  5. Rotate the lock catch to the "CLOSE" direction to securely lock the flexible coil.
Flexible coil clamp meter measuring current by wrapping the coil around a wire.

Figure 2: Illustration of the flexible coil in use, demonstrating how to wrap the coil around a wire to improve test resolution for small currents.

For small currents, resolution can be improved by wrapping the flexible coil multiple times around the measured wire. For example, if the actual current is 10A and the coil is wrapped 3 times, the meter will display 30A. The actual current is then the displayed value divided by the number of windings.

Video 1: Demonstration of the flexible current clamp meter's features, including coil flexibility, measurement function switching, and various measurements.

5.3. Voltage Measurement

  1. Start the meter.
  2. Press the A/V/Ω key to switch to voltage test mode (V).
  3. Connect the test cables to the circuit. The instrument will display the voltage value and automatically identify whether it is AC or DC voltage.
Clamp meter probes measuring AC voltage from a power strip.

Figure 3: AC/DC Voltage Test setup, showing probes inserted into a power outlet for AC voltage measurement.

5.4. Resistance Measurement

  1. Start the meter.
  2. Press the A/V/Ω key to switch to resistance test mode (Ω).
  3. Connect the test leads to the specimen. The instrument will display the resistance value.

5.5. Backlight Control

After turning on the device, press the Backlight button icon button to control the backlight. This feature is useful in dim environments or at night. The backlight is on by default when the device is turned off.

5.6. Data Hold and Storage

Press the HOLD key to freeze the current displayed data. The "HOLD" symbol will appear on the LCD. Pressing HOLD again will cancel data retention. While data is held, the instrument automatically numbers and saves the data. The meter can store up to 600 groups of data.

5.7. Data Access and Exit

In measurement mode, press the MEM key to enter data viewing mode. The "MR" symbol will be displayed. Data viewing starts from "READ:001". Press HOLD to increment through groups, and MEM to decrement. Press and hold MEM to exit data viewing mode.

5.8. Data Cancel

Enter data viewing mode. Long press the Backlight button icon key to enter the data deletion option. Use HOLD or SET to select YES or NO. Select YES and long press MEM to clear all data and return to data viewing mode. Clicking Backlight button icon will return to data viewing mode.

6. Maintenance

  • After each measurement, especially current measurements, ensure the clamp head is clean and free from debris.
  • Store the device in a dry environment, away from extreme temperatures and direct sunlight.
  • If the device will not be used for an extended period, remove the batteries to prevent leakage.

7. Troubleshooting

  • "OL" Symbol Displayed: If the meter displays "OL" during current measurement, it indicates that the measured current exceeds the upper limit of the meter's range. Do not attempt to measure currents beyond the specified maximum.
  • Inaccurate Current Readings: Ensure the tested wire is positioned as centrally as possible within the flexible coil (near point A in the diagram). Errors increase significantly near the opening/closing point (area C) and near position point B. For small currents, try wrapping the coil multiple times around the wire to improve resolution.
  • No Display/Device Not Turning On: Check battery installation and ensure batteries have sufficient charge.

8. User Tips

  • The flexible coil design is particularly useful for measurements in tight spaces or environments with dense wiring, such as inside distribution cabinets, where traditional clamp meters might not fit.
  • When measuring small currents, wrapping the flexible coil around the wire multiple times can significantly improve the accuracy and resolution of your readings. Remember to divide the displayed value by the number of wraps to get the actual current.

9. Frequently Asked Questions (FAQ)

Q: Does the SWEVY SW1018A detect leakage currents?
A: The primary functions of the SW1018A are for measuring AC/DC voltage, AC current, and resistance. Specific leakage current detection is not explicitly listed as a feature in the provided specifications. For advanced features, please consult the full user manual PDF.
Q: What languages does the interface support?
A: The device's display is digital and uses universal symbols and numerical values. The operational text and menu options are typically in English. For detailed language settings or alternative language manuals, please refer to the official product documentation.

10. Warranty and Support

For detailed warranty information, technical support, or further inquiries, please refer to the official product documentation or contact SWEVY customer service.

A comprehensive user manual in PDF format is available for download: SWEVY SW1018A User Manual (PDF).

© 2023 SWEVY. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.