1. Safety Instructions
- For your safety, please read this user manual carefully before initial operation.
- This photocell is supplied without an internal fuse. Always ensure the power supply is OFF before installation or maintenance to prevent electrical shock.
- Only use this system for its intended purpose. Do not use it in applications where failure could cause danger to life or property.
- Ensure the product is used within its specified effective working range.
2. Product Overview
The Yinuogo YNG207 is a single infrared beam sensor designed for gate and garage door safety applications. It operates by emitting an infrared beam from a transmitter unit to a receiver unit. When the beam is interrupted, the sensor triggers a switch signal (NC/NO) to an external device, indicating an obstruction.

2.1. Package Contents
Before installation, please check that all components are present:
- 1x Infrared Beam Transmitter Unit
- 1x Infrared Beam Receiver Unit
- Mounting Screws and Anchors
- User Manual (this document and/or PDF)

3. Setup and Installation
3.1. Mounting
- Choose a suitable location for both the transmitter and receiver units. They should be mounted directly opposite each other, ensuring a clear line of sight for the infrared beam.
- Mount the units securely using the provided screws and anchors. Ensure they are stable and will not vibrate or shift after installation.
- The recommended mounting height is typically 20-60 cm (8-24 inches) from the ground, but this may vary based on the specific application.
3.2. Wiring
IMPORTANT: Ensure power is OFF before proceeding with wiring.
The sensor operates on DC 12V or 24V. It provides both Normally Closed (NC) and Normally Open (NO) relay outputs.

Refer to the terminal labels on the circuit board for correct connections:
- Power Input: Connect your DC 12V/24V power supply to the designated power terminals (usually marked + and - or VCC and GND).
- Relay Output: Connect the control wires of your gate opener or alarm system to the NC (Normally Closed) or NO (Normally Open) terminals, and the Common (COM) terminal, as required by your system.
3.3. Alignment
- After wiring, apply power to the units.
- Carefully align the transmitter and receiver units so that the infrared beam is directly aimed at the receiver's lens.
- Most units have an indicator LED (often red or green) that illuminates or changes state when proper alignment is achieved. Adjust the position of the units until this indicator shows a stable, aligned state.
- Once aligned, tighten all mounting screws to secure the units in place.
4. Operating Instructions
Once properly installed and aligned, the YNG207 sensor operates automatically:
- When the infrared beam between the transmitter and receiver is unbroken, the sensor's relay output will be in its default state (NC closed, NO open).
- When an object (e.g., a vehicle, person, or animal) interrupts the infrared beam, the receiver detects the interruption.
- Upon beam interruption, the sensor's relay output changes state (NC opens, NO closes), sending a signal to the connected control system (e.g., to stop or reverse a gate).
5. Maintenance
To ensure reliable operation and longevity of your YNG207 sensor, perform the following maintenance tasks periodically:
- Clean Lenses: Regularly clean the lenses of both the transmitter and receiver units with a soft, damp cloth to remove dust, dirt, spiderwebs, or other obstructions that could interfere with the infrared beam.
- Check Alignment: Periodically verify that the units are still properly aligned. Strong winds, impacts, or ground settling can cause misalignment. Re-align if necessary.
- Inspect Wiring: Check all wiring connections for corrosion, damage, or loose terminals. Ensure all connections are secure and protected from the elements.
- Clear Obstructions: Ensure there are no permanent or temporary obstructions (e.g., overgrown plants, debris) in the path of the infrared beam.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Sensor not responding / No power indicator | No power supply; Incorrect wiring; Faulty unit | Check power connections and voltage; Verify wiring according to diagram; Test with a known good power supply. |
| Sensor constantly triggered / Not detecting beam | Misalignment; Obstruction in beam path; Dirty lenses; Direct sunlight interference | Re-align units carefully; Remove any obstructions; Clean lenses; Shield sensor from direct sunlight if possible. |
| Intermittent triggering | Loose wiring; Unstable mounting; Partial obstruction; Environmental interference | Check and secure all wiring; Ensure units are firmly mounted; Clear beam path; Check for sources of interference. |
7. Specifications
| Feature | Specification |
|---|---|
| Model Number | YNG207 |
| Brand Name | yinuogo |
| Name | IR photocell sensor |
| Style | Single beam wired |
| Input Power | DC 12V / 24V |
| Switch Signal | NC / NO (Normally Closed / Normally Open) |
| Detection Range | Up to 15 meters |
| Waterproof Rating | IP55 |
| Certification | CE |
| Origin | Mainland China |
8. User Tips
- Precise Alignment: Take extra time during installation to ensure perfect alignment. This is the most critical factor for reliable operation.
- Secure Mounting: Ensure both sensor units are mounted on stable surfaces that are not prone to vibration or movement, which can lead to misalignment over time.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original seller or the manufacturer directly. Please have your model number (YNG207) and purchase details ready.
An additional user manual in PDF format may be available for download: View PDF User Manual
10. Product Video
Watch a brief introduction to the Yinuogo brand:
Video 1: Yinuogo Brand Introduction