1. Important Safety Instructions

WARNING: CAREFULLY READ AND FOLLOW ALL SAFETY INSTRUCTIONS

  • Carefully read this manual before the controller is installed and operated; retain the manual in a safe place for future reference.
  • The controller must not be installed or operated by anyone lacking appropriate knowledge, experience, or competence, or by anyone with compromised physical, sensory, or mental capabilities, unless under strict instruction and supervision.

Controller Installation and Operation

  • There are no serviceable parts for this controller. Do NOT disassemble or attempt to repair the controller.
  • Install the controller in a location with good natural airflow/ventilation and sufficient unobstructed space around it.
  • Install the controller on a non-flammable substrate and ensure no heat-sensitive items are in the immediate vicinity. It is normal for the controller to become hot during operation.
  • Install the controller in a location protected from environmental conditions such as direct sunlight, water, high moisture, and dust, and well away from any flammable liquids or gases. Controller is for indoor use only.
  • Do not install or place/operate the controller on top of the battery, directly above the battery, or in a sealed compartment with the battery; batteries can emit explosive gases.
  • Do not cover or place any other items on top of the controller.

Battery Installation and Charging

  • Install and charge the battery in a location with good natural airflow/ventilation.
  • Ensure that there are no ignition sources near the battery; batteries can emit explosive gases.
  • Battery acid is corrosive; if battery acid comes into contact with skin, immediately rinse with water.
  • Do not charge non-rechargeable batteries or Li-ion batteries if the battery temperature is below 0°C. Never charge a frozen battery.
  • Ensure that the unit is properly set up for the type of battery intended to be charged.

Battery DC Connections

  • Ensure that the DC system is fully shut down/isolated prior to disconnection of any existing cabling and/or new connections are made to the battery/DC system.
  • Use flexible multi-stranded copper cable with sufficient cross-sectional area, line with an appropriate fuse or circuit breaker.
  • NEVER connect the solar panel array to the controller without a battery. Battery must be connected first.

Controller Setup

  • Refer to the battery manufacturer's instructions and specifications to ensure the battery is suitable for use with this controller and confirm the recommended charge settings.
  • The integrated charge modes combined with adaptive charge logic are well suited for most common battery types, such as flooded lead-acid, Gel, and LiFePO4.

2. Product Overview

The PowMr MPPT Solar Charge Controller uses numerical control technology design with an LCD display for automatic operation. It features Maximum Power Point Tracking (MPPT) for efficient battery charging, extending battery life. The controller is suitable for independent solar energy systems, automatically managing charging and discharging processes. It includes self-diagnostics and electronic protection functions to prevent damage from installation errors or system failures.

The POW-M60-MAX model has been optimized and upgraded, featuring a humanized LCD screen display algorithm that allows all parameters to be monitored and configured through a single interface.

PowMr MPPT Solar Charge Controller with numbered components
Figure 1: PowMr MPPT Solar Charge Controller Components
No. Component Description
1 LCD display screen Displays operational data and settings.
2 Function keys Buttons for navigation and setting adjustments.
3 PV input terminal Connection point for solar panel array.
4 Battery terminal Connection point for battery bank.
5 Load terminal Connection point for DC loads.
6 Mount hole Holes for mounting the controller to a surface.
7 Heat sink Finned surface for heat dissipation.

3. Features

  • Integrated Charge Presets: Well-suited for common battery types like LiFePO4, Gel, and flooded lead-acid.
  • Flexible Application: Compatible with 12V/24V/36V/48V system voltage.
  • Multi-stage Charge Algorithm: Optimizes each recharge cycle and charge maintenance.
  • MPPT Tracking Technology: Maximizes energy harvest from solar PV modules by tracking the array's maximum power point voltage (Vmp).
  • High Efficiency: Innovative MPPT technology with up to 99% tracking efficiency and 98% peak conversion efficiency, leading to lower power usage and cooler operation.
  • Adaptive Boost Charge: Monitors battery response during initial charging to determine appropriate boost charge duration, ensuring full recharge and preventing accelerated battery aging.
  • Durable and Safe: Includes protections such as maximum charging current limit, PV array short circuit protection, PV input overcurrent protection, controller overload protection, load short circuit protection, PV reverse polarity protection, battery reverse polarity protection, and over-temperature protection.
  • Silent Operation: No cooling fan or moving parts; cooling is via natural convection.
  • Lithium Battery Activation: Compatible with Li-ion (LiFePO4) batteries. The controller can activate a protected lithium battery using solar energy. Warning: Do not charge Li-ion batteries if the battery temperature is below 0°C.
  • Enhanced User Interface with a Large Screen: Expanded LCD display for improved user experience.
  • Built-in Dedicated Wiring Terminals: Convenient plug-and-play design saves installation time and prevents reverse connection errors.
  • Alarm Function: Integrated alarm for protection and fault alerts.

4. Setup (Installation and Connection)

4.1 Unpacking and Inspection

Before unpacking, check for package damage. After unpacking, verify contents and check for damage or missing items. The package should contain:

  • Controller
  • User manual
  • Screws/bolts
  • Special cable with terminals
  • Special cable terminals
Video 1: Unboxing and basic connection demonstration for the PowMr MPPT Solar Charge Controller.

4.2 Preparing for Installation

The controller is designed for wall mounting using flanges. Consider the following for a suitable and safe location:

  • Good natural airflow/ventilation.
  • Sufficient unobstructed space: A minimum clearance of 75mm above and below is recommended.
  • Non-flammable substrate.
  • Protection from direct sunlight, water, high moisture, dust, and flammable liquids/gases.
  • Do not install on top of or directly above the battery, or in a sealed compartment with the battery.
  • Do not cover the controller or place other items on it.
  • Install using four M5 screws.

4.3 Things You Need

Product Quantity
POW-M60-MAX Controller 1
DC-cable to connect the positive DC connection (+) of the controller to the positive pole of the DC-distribution 3
DC-cable to connect the negative DC connection (-) of the controller to the negative pole of the DC-distribution 3
DC breaker 3
Screws / bolts (Ø5mm) to mount the cabinet to a surface. Use mounting materials which are suitable to carry the weight of the controller. 4
PV array. 1
Battery pack. 1

NOTICE: For all wirings and circuits specifications see section "4.4 DC Breaker Type".

4.4 DC Breaker Type

  • PV input circuit breaker type: Determine based on maximum PV input current and system voltage. The voltage in series shall not exceed maximum PV input open-circuit voltage.
  • Recommended specifications for the DC circuit breakers for load output circuit:
    Model Max. DC output Current Circuit Breaker Spec
    POW-M60-MAX 30A 2P-32A
  • The DC circuit breakers of the battery should be selected based on the maximum charging current of the battery you connected.

4.5 PV Module Selection

When selecting proper PV modules, consider the following parameters:

  1. Open circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of controller.
    Controller mode POW-M60-MAX
    Max. PV array open circuit voltage of controller 160V
  2. Open circuit Voltage (Voc) of PV modules should be higher than Min. battery voltage.

4.6 Wiring Precautions

  • Installation and connection work must be done by a licensed electrician.
  • Loose connections can cause dangerous overheating. Tighten all connections well and use correct cable sizes.
  • Install separate circuit breakers for each circuit for safety and easy maintenance.
  • Do not connect the inverter to the load side of the controller to avoid irreversible damage.
Wiring diagram for PowMr MPPT Solar Charge Controller showing connections for PV array, battery, and load.
Figure 2: System Application Diagram of the Controller

4.7 Installation and Connection Step-By-Step

  1. Mounting: Mark and drill 4 mounting holes based on the controller's mount holes. Insert expansion rubber screw plugs. Mount the controller vertically with terminals facing down, securing with M5 screws.
  2. Battery Connection: Connect the battery to the controller with the cables.

    NOTICE:

    • All wiring must be performed by qualified personnel.
    • For safe operation, a circuit breaker of corresponding specifications must be installed on the cable connecting to the controller. Ensure the wire is thick enough.
    • Ensure all circuit breakers are open until all cables are connected.
    • The positive end of the cable shall be connected to the positive port (+), and the negative end to the negative port (-).
    • These precautions also apply to PV side and load side wiring.
  3. PV Connection: Connect the PV array to the controller with the cables.
  4. DC Output Connection: Connect the load to the controller with the cables.
  5. Check before starting up: Refer to the wiring details in Figure 3. If all connections are firm and correct, close the circuit breakers at the battery side, PV module side, and load side in sequence to start the controller.
Wiring diagram showing connections from PV array to controller, controller to battery, and controller to load.
Figure 3: Wiring Diagram for PV, Battery, and Load Connections

WARNING: Risk of electric shock! Make sure that all power is turned off before operations, then follow inspections and operations.

5. Operation

5.1 Charging Mode

The charging controller features an intelligent 3-stage charge characteristic for optimal battery charging. When switched on, the controller always starts at the Bulk stage.

The three integrated charge modes (Bulk, Boost, Float) ensure fast, efficient, and safe battery charging, extending battery life. These modes are well suited for common battery types.

Charging mode parameters can be set via the LCD screen. Any settings made are stored and will not be lost if the controller is disconnected from the battery or PV module.

Bulk Charge:

The battery is charged at maximum current until the voltage reaches the configured boost charge voltage. Duration depends on discharge level, battery capacity, and charge current.

Boost Charge:

The battery is charged at the configured boost charging voltage, with current slowly decreasing as the battery approaches full charge. The default boost stage duration is adaptive. If the photovoltaic module is reconnected, a new charging cycle starts. If the battery is full, it directly enters stage B (boost charging voltage stage) for 30 minutes.

Float Charge:

After boost charging, the controller reduces battery voltage by reducing charging current, maintaining the battery at the floating charging voltage. In this stage, loads can draw power from the solar panel. If loads exceed power, the controller may not maintain battery voltage, and if battery voltage drops below Recharge Voltage, it returns to Bulk charging stage.

5.2 Icon Display on LCD Screen

LCD display screen of the PowMr MPPT Solar Charge Controller showing various icons and numerical readouts.
Figure 4: LCD Display Screen Icons
No. Function
1 Day or night indicating icon
2 Indicates the remaining battery capacity
3 Working mode
4 Periodic running status of the load and warning state
5 Indicate PV input voltage/power
6 Indicate Current battery voltage/Charging current/Equipment temperature/Battery calibration voltage/Battery type/Boost charging voltage/Float charging voltage/Low DC cut-off recovery voltage/ Low DC cut-off voltage.
7 Indicate working mode of load.

5.3 Function Keys

Icon Description
PV / # To switch the PV input parameters information
BAT / ▲ To switch the charging information/ Return the previous option.
DC / ▼ To adjust DC output mode and DC output operation duration/ Enter the next option.
SET / # Confirm and reserve the settings.

5.4 Browse and Configuration Step-By-Step

NOTICE: The screen will automatically turn off the backlight after about 25 seconds without pressing a button to save power. Press any key to reactivate.

5.4.1 PV Side

Step 1. Checking PV input Information: Press "PV / #" key to switch PV information, which is PV input voltage and PV input power in sequence.

5.4.2 Battery Side

Step 1. Checking Battery Information: Press "BAT / ▲" key to switch battery information, which is current battery voltage, charging current, equipment temperature, battery calibration voltage, battery type, boost charging voltage, float charging voltage, low DC recovery cut-off voltage, low DC cut-off voltage in sequence.

Step 2. Calibrate Battery Voltage

To correct the current battery voltage measured by the controller:

  1. When the parameter switches to "battery calibration voltage" item, press and hold "BAT / ▲" key to enter the battery voltage calibration setting.
  2. Press "BAT / ▲" or "DC / ▼" keys to calibrate the battery voltage parameters according to the battery voltage measured by a multimeter. Finally, press "SET / #" to confirm.
Step 3. Select the Battery Type

Adjust battery type parameters based on the connected battery:

  1. When the parameter switches to the battery type item, press and hold "BAT / ▲" key to enter the battery type adjustment setting.
  2. Press "BAT / ▲" or "DC / ▼" to adjust battery type, then press "SET / #" to confirm. The operating voltage varies according to battery types.

For details, refer to "5.4.3 Battery parameters of different types" section.

Sequence Display Battery Type
1 SEL Sealed lead acid battery
2 GEL Colloidal lead acid battery
3 FLd Vented lead acid battery
4 L04 4-Series LiFePO4 Battery
5 L07 7-Series LiFePO4 Battery
6 L08 8-Series LiFePO4 Battery
7 L15 15-Series LiFePO4 Battery
8 L16 16-Series LiFePO4 Battery
9 N03 3-Series Lithium-Ion Battery
10 N06 6-Series Lithium-Ion Battery
11 N07 7-Series Lithium-Ion Battery
12 N13 13-Series Lithium-Ion Battery
13 N14 14-Series Lithium-Ion Battery
14 USE User-defined
Step 4. Customize Configured Voltage Parameters

NOTICE: This step is required only when the battery type is set to "USE".

  1. When battery type is "USE", configurable parameters are presented in the following order (increment of each click is 0.1V).
Item Setting Range
Nominal system voltage 12V/24V/36V/48V (optional)
Boost charging voltage 10.0~17.0V
Float charging voltage 10.0~17.0V
Low DC cut-off recovery voltage 10.0~15.0V
Low DC cut-off voltage 10.0-15.0V
  1. Press "BAT / ▲" key to select the parameter item to adjust.
  2. Press and hold "BAT / ▲" key to enter the related parameter, then press "BAT / ▲" or "DC / ▼" to adjust the voltage value.
  3. Finally, press "SET / #" to confirm.

CAUTION: The preceding parameter ranges apply to 12V battery. For 24V/36V/48V batteries, range values are 2/3/4 times this range, respectively. The LCD only displays 12V battery voltage.

WARNING: Settings must follow this logic: Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage.

5.4.3 Load Side

Step 1. Configure Load Enable Duration:

  1. Press and hold "DC / ▼" key to enter the load mode setting.
  2. Press "BAT / ▲" or "DC / ▼" to adjust load state or load enable duration.
  3. Finally, press "SET / #" to confirm.
  • 00H: Solar light control mode (loads supply power after dark, stop at dawn).
  • 24H (Default): Load turns on immediately. A short press of "DC / ▼" immediately shuts off load output.
  • 01H-23H: Adjust load enable duration (1-hour increments).
5.4.4 Working Mode
Code Description
3.0 Night mode, no charging
4.0 Bulk charging mode (MPPT mode)
7.0 Boost charging mode
8.0 Float charging mode
5.4.5 Key Points Battery Parameter Settings

The logic for setting battery voltage parameters:

  1. Before customizing battery parameters, confirm the Max charging voltage and Discharging protection voltage of the connected battery.
  2. After confirming battery information, set the 4 key parameters according to this logic: Max. charging voltage > Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage > Discharge protection voltage.
For Lead-Acid Battery & User Define:
Parameter FLd GEL SEL USE
Boost charging voltage 14.6V 14.2V 14.4V 10.0~17.0V
Float charging voltage 13.8V 13.8V 13.8V 10.0~17.0V
Low DC cut-off voltage 11.0V 11.0V 11.0V 10.0~15.0V
Low DC cut-off recovery voltage 12.6V 12.6V 12.6V 10.0~15.0V
For Ternary Lithium Battery:
Parameter N03 N06 N07 N13 N14
Boost charging voltage 12.5V 25.0V 29.2V 54.2V 58.3V
Float charging voltage 12.2V 24.4V 28.5V 52.9V 56.9V
Low DC cut-off voltage 8.4V 16.8V 19.6V 36.4V 39.2V
Low DC cut-off recovery voltage 9.0V 18.0V 21.0V 39.0V 42.0V
For Lithium Iron Phosphate Battery:
Parameter L04 L07 L08 L15 L16
Boost charging voltage 14.5V 25.4V 29.0V 54.4V 58.0V
Float charging voltage 13.8V 24.1V 27.6V 51.8V 55.2V
Low DC cut-off voltage 11.2V 19.6V 22.4V 42.0V 44.8V
Low DC cut-off recovery voltage 12.0V 21.0V 24.0V 45.0V 48.0V

6. Maintenance

The following inspections and maintenance tasks are recommended at least two times per year for best performance:

  • Ensure the controller is firmly installed in a clean and dry environment.
  • Ensure no block on airflow around the controller. Clear any dirt and fragments from the radiator.
  • Check all naked wires to ensure insulation is not damaged from solarization, frictional wear, dryness, insects, or rats. Repair or replace damaged wires if necessary.
  • Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
  • Confirm that all system components are grounded tightly and correctly.
  • Confirm that all terminals have no corrosion, insulation damage, high temperature, or burnt/discolored signs. Tighten terminal screws to the suggested torque.
  • Check for dirt, nesting insects, and corrosion. If found, clear up in time.

WARNING: Risk of electric shock! Make sure that all power is turned off before operations, then follow inspections and operations.

7. Troubleshooting

In case of a failure, the controller display shows an error signal to help you find its source.

Fault code Possible Cause What to do
18 Input PV voltage is low Increase the number of photovoltaic panels; or increase the photovoltaic input voltage value in series.
60 Over-temperature protection When the temperature of the device is cooled below the recovery temperature, normal charge and discharge control is resumed.
63 Battery voltage is high Measure whether the battery voltage exceeds the rated voltage and turn off the photovoltaic array air switch.
65 Battery voltage is low Charge the battery and wait until the battery voltage is higher than the low voltage cut-off voltage recovery point.
71 Input PV voltage is high Reduce the number of PV panels connected to the controller to reduce the PV input; or reduce the voltage or current value by changing the series or parallel mode.
73 Over-charging current Reduce the voltage or current value by changing the series or parallel mode.

8. Technical Specifications

Category Parameter Value (POW-M60-MAX)
PV Input Max. Input Power (12V system) 720W 20-80Vdc
Max. Input Power (24V system) 1440W 37-105Vdc
Max. Input Power (36V system) 2100W 50-160Vdc
Max. Input Power (48V system) 2800W 72-160Vdc
Input Voltage Range 20V~160V (system dependent)
Charge Mode Charging Technology MPPT
Charge Algorithm 3-Stage
Nominal System Voltage 12V/24V/36V/48V
Rated Charging Current 60A
Efficiency Conversion Efficiency ≤98%
MPP Tracking Efficiency >99%
Self-consumption Self-consumption 0.7W-1.2W
DC Output Rated Output Current 25A
Max. DC Output Current 30A
Max. Capacitive Load Capacity 10000µF
Environment Operating Temperature Range -35°C~+45°C
Humidity Range ≤95%, Non-condensing
Altitude <3000m
General Specification Protection Class IP32
Dimension 230*165*72mm (9.1*6.5*2.8in)
Net Weight 1.45kg (3lbs)

9. User Tips

No specific user tips available from provided data.

10. Warranty and Support

For technical support or warranty inquiries, please contact:

  • Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Website: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

For complete details regarding product warranty and service, please refer to the official user manual PDF available at this link.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.