Introduction
Thank you for choosing the PowMr MPPT series solar charge controller. This manual provides essential safety, installation, and operating instructions to ensure the proper and efficient use of your charge controller within your solar system. The HHJ-60A model is a powerful MPPT solution with a 60A charging current and 99.9% tracking efficiency, featuring a high-performance DSP controller for fast digital signal processing.
For a comprehensive guide, you may also refer to the official user manual PDF: View User Manual (PDF).
Video: Introduction to the HHJ-60A Solar Charge Controller, highlighting its features and benefits.

Image: Front view of the PowMr MPPT 60A Solar Charge Controller, showing the display and terminals.
Important Safety Instructions
WARNING: Indicates a potentially dangerous condition. Use extreme caution when performing this task.
CAUTION: Indicates a critical procedure for safe and proper operation of the controller.
NOTE: Indicates a procedure or function that is important to the safe and proper operation of the controller.
General Safety Information
- Read all instructions and cautions in the manual before beginning installation.
- There are no serviceable parts for this controller. Do NOT disassemble or attempt to repair.
- Do NOT allow water to enter the controller.
- Make sure all connections going into and from the controller are tight.
Charge Controller Safety
- NEVER connect the solar panel array to the controller without a battery. The battery must be connected first.
- Ensure input voltage does not exceed 190 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to make sure the voltage does not exceed this value when connecting panels together.
Battery Safety
- Use only sealed lead-acid, flooded, gel, or lithium batteries which must be deep cycle.
- Explosive battery gases may be present while charging. Ensure adequate ventilation to release gases.
- Be careful when working with large lead-acid batteries. Wear eye protection and have fresh water available in case of contact with battery acid.
- Carefully read battery manuals before operation.
- Do NOT let the positive (+) and negative (-) terminals of the battery touch each other.
- Recycle the battery when it is replaced.
- Over-charging and excessive gas precipitation may damage battery plates. Too high or too long an equalizing charge may cause damage. Review specific battery requirements.
- Equalization is for non-sealed/vented/flooded/wet cell lead-acid batteries only.
- Do NOT equalize VRLA type AGM/Gel/Lithium cell batteries UNLESS permitted by the battery manufacturer.
Liability Disclaimer
The manufacturer is not liable for damages, especially to the battery, caused by use other than as intended or as mentioned in this manual, or if the recommendations of the battery manufacturer are neglected. The manufacturer is not liable if service or repair is carried out by any unauthorized person, or due to unusual use, wrong installation, or bad system design.
Key Features
The PowMr MPPT solar charge controller is designed with advanced Maximum Power Point Tracking (MPPT) technology, offering high efficiency and robust performance for various solar systems. Its conversion efficiency can reach up to 97%.
- Model: HHJ-60A solar charge controller
- 100% MPPT technology for optimal power harvesting
- Built-in DSP controller for high performance and fast digital signal processing
- Automatic voltage switch for 12V/24V/36V/48V battery banks
- Multi-stage charging (3-stage) to optimize battery performance and extend battery life
- Comprehensive protection features: Overcharge protection, input PV polarity reverse protection, output limited current protection, over-temperature protection
- Fault diagnosis system for easy troubleshooting
- Compatible with various battery types: sealed lead-acid, vented, gel, and lithium batteries
- Easy to mount design

Image: Comparison highlighting PowMr's 99% efficiency, 12V/24V/36V/48V battery compatibility, and higher current/PV voltage limits (Max.PV 160VDC).

Image: Diagram illustrating the 3-stage charging process (Equalize Charge, Boost Charge, Float Charge) for rapid, efficient, and safe charging, with peak conversion efficiency of 98% and high tracking efficiency up to 99%.
Dimensions
The physical dimensions of the HHJ-60A solar charge controller are provided below:
- Size (L x W x H): 214mm x 115mm x 50mm (8.43in x 4.53in x 1.97in)
- Net weight: 1.1 kg (2.43 lb)
- Gross weight: 1.2 kg (2.65 lb)

Image: Technical drawing showing the dimensions of the controller: 21.4cm length, 11.5cm width, 5cm height.
Installation and Setup
WARNING: Connect battery terminals to the charge controller BEFORE connecting the solar panel(s) to the charge controller. NEVER connect solar panels to the charge controller until the battery is connected.
WARNING: Do NOT connect any inverters or battery chargers into the load terminal of the charge controller.
CAUTION: Use only the provided screws for mounting. Using other screws may damage the internal PCB. Apply proper torque to avoid damage.
Installation Steps
- **Connect the Batteries:**
- Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (marked with the battery symbol).
- If the system is 12V, ensure your battery voltage is above 12V for the controller to boot up.
- **Connect the Solar Panel:**
- Ensure that the PV modules are protected from incident light during connection.
- Ensure the solar panel's maximum permissible input current is not exceeded.
- Connect the PV modules connection cable to the correct polarity of the left pair of terminals on the solar charge controller (marked with the PV modules symbol).
- **Connect Loads:**
- Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (marked with the lamp symbol).
- To avoid any voltage on the wires, connect the wire to the load before connecting to the controller.
- **Final Steps:**
- Tighten all cables connected to the controller.
- Remove all debris around the controller, leaving a space of approximately 5.91 inches (15 cm) for ventilation.
Wiring Diagram

Image: Detailed wiring diagram showing connections for PV Solar Panels, MPPT Charge Controller, Battery, DC Load, AC Load, and Inverter. It also indicates maximum PV input 160VDC and system power for 12V (720W), 24V (1440W), 36V (2100W), and 48V (2800W) systems. The diagram also illustrates parallel support for two 60A controllers to achieve 120A MPPT.
NOTE: It's recommended to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, the wiring method is the same.
Air Circuit Breaker Installation
We strongly recommend connecting a fuse directly to the battery to protect against short circuits in the battery wiring. Solar PV modules generate current when exposed to light. Protect solar modules from incident light during installation. Always use insulated tools and ensure wire diameter is appropriate for expected currents.
| Models | Copper wires | Air circuit breakers |
|---|---|---|
| HHJ-60A | 6mm²x2PCS | 100A |
NOTE: When the PV or battery readings are constantly changing, the controller is likely finding the Maximum Power Point (MPP). This is normal. If issues persist, contact technical support.
Operation
Initial Power-On and Self-Test
- Install air circuit breaker between controller and batteries. Turn off the circuit breaker, then connect batteries to controller with correct polarity.
- Install air circuit breaker between controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity is correct, then connect wires between PV modules and controller.
- Turn on the air circuit breaker between controller and batteries.
- Turn on the air circuit breaker between controller and PV modules.
- The controller will enter self-test mode. The LCD will display parameters if all connections are correct. The RUN lamp (under the fan inside the casing) will flash every one second. If the controller does not respond, re-check the manual for reinstallation or contact support.
LCD Display and Working Modes
The controller features a backlight LCD screen that displays various parameters and allows for configuration. The main interface shows PV voltage/output power, battery voltage/charging current, working mode/temperature, and fault codes.

Image: The controller's LCD display showing various parameters and the fan cooling system. The sub-interface displays Load Timer, Floating Voltage, Absorption Voltage, Battery Type, Calibration Voltage, and Under-voltage Disconnection Voltage.
| Item | Description |
|---|---|
| 1 | PV voltage / Output power |
| 2 | Battery voltage / Charging current |
| 3 | Working mode / Temperature |
| 4 | Fault code |
Working Modes
| Mode | Description |
|---|---|
| 3.0 | Night mode, no charging |
| 4.0 | MPPT mode |
| 7.0 | Absorption mode |
| 8.0 | Floating mode |
Manual Settings
NOTE: The controller will work fine under default settings, except for lithium batteries, which may require manual adjustment.
CAUTION: All manual setting steps must be performed when the PV modules are disconnected from the controller.
- **Step 1: D00 (Load Working Time)**
- Press the PRG button until the LCD displays D00. This sets the load working time (default is 24 hours).
- Press ENT until numbers flash, then use UP/DOWN to set the desired time. Long-press ENT to confirm.
- The output voltage is the same as the battery voltage. This load setting is for small DC loads less than 5A. If no load, leave it.
- **Step 2: D01 (Float Charging Voltage)**
- Press the UP button; the LCD shows 13.8 (default float charging value).
- Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.
- CAUTION: This value is for a single 12V battery. For multiple batteries in series, the controller automatically multiplies the voltage proportionally. The LCD will only display the voltage per battery.
- **Step 3: D02 (Absorption Charging Voltage)**
- Continue pressing the UP button; the LCD shows 14.5 (highest absorption charging voltage for battery).
- Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.
- CAUTION: Similar to D01, this value is for a single 12V battery. The controller will adjust proportionally for series battery banks.
- **Step 4: D03 (Under-Voltage Disconnect Protection)**
- Continue pressing the UP button; the LCD shows 10.0. This is the protection value for battery discharge.
- Press ENT until numbers flash, then use UP/DOWN to set the desired voltage. Long-press ENT to confirm.
- This means the load will be disconnected if a 12V battery drops below 10.0V.
- **Step 5: D04 (Battery Voltage Calibration)**
- Continue pressing the UP button; the LCD shows C12.2. This setting calibrates the battery voltage.
- Adjust the value to ensure the battery voltage detected by the controller matches the actual battery voltage.
- **Step 6: D05 (Battery Type Setting)**
- Continue pressing the UP button; the LCD shows the battery type setting program. The default is USE (User-defined).
- Available battery types:
Type Description SEL Sealed Lead-Acid Battery GEL Gel Sealed Lead-Acid Battery FLd Flooded Lead-Acid Battery L04 4-series Lithium Iron Phosphate Battery L08 8-series Lithium Iron Phosphate Battery L15 15-series Lithium Iron Phosphate Battery L16 16-series Lithium Iron Phosphate Battery USE User-defined Battery Type CAUTION: When selecting SEL, GEL, and FLd battery types, the controller automatically detects the system voltage.
- **Step 7: D06 (System Voltage Configuration for USE type)**
- If you selected the USE option in D05, you must manually configure the system voltage here.
- The configuration range is 12V/24V/36V/48V.
Press ESC to exit the setting menu.
NOTE: After completing all settings, disconnect the battery and then reconnect it to verify settings are successful. Once confirmed, connect the PV modules.
Battery Charge Voltage Reference
| Battery Type | Float Charging Voltage | Absorption Charging Voltage | Under-voltage Protection |
|---|---|---|---|
| SEL | 13.8 | 14.4 | 11.0 |
| GEL | 13.8 | 14.2 | 11.0 |
| FLd | 13.8 | 14.6 | 11.0 |
| L04 | 13.8 | 14.5 | 11.2 |
| L08 | 27.6 | 29.0 | 22.4 |
| L15 | 51.8 | 54.4 | 42.0 |
| L16 | 55.2 | 58.0 | 44.8 |
| USE | Defined by users | ||
Maintenance
- **Regular Inspection:** Periodically check all wiring connections to ensure they remain tight and secure. Loose connections can cause sparks or inefficient operation.
- **Environmental Conditions:** Ensure the controller is kept dry and away from water or excessive moisture.
- **Ventilation:** Maintain adequate clearance around the controller (at least 5.91 inches or 15 cm) to ensure proper airflow and prevent overheating. The fan uses bearing technology for increased life up to 5000 hours and high-airflow exhaust fan design to ventilate heat.
- **Cleaning:** Keep the controller free from dust and debris to ensure optimal performance of the cooling fan and internal components.
- **Battery Care:** Follow the specific maintenance guidelines for your battery type (sealed lead-acid, flooded, gel, or lithium) as outlined in their respective manuals. Ensure proper ventilation during battery charging to dissipate any explosive gases.
Troubleshooting and Protections
The HHJ-60A controller includes a fault diagnosis system to help identify and resolve issues. It also features multiple built-in protection programs to ensure safety and longevity.
Troubleshooting Guide
| Code | Description | How to solve |
|---|---|---|
| 18 | Input PV voltage is low | Increase the PV voltage |
| 60 | Over-temperature protection | Fan will work and temperature reduction automatically |
| 63 | Battery voltage is high | Battery high voltage protection and wait for recovery |
| 65 | Battery voltage is low | Battery over-discharge and wait for recovery |
| 71 | Input PV voltage is high | Decrease the PV voltage |
| 73 | Over-charging current | Decrease the PV power |
Built-in Protections
- **PV Over Current:** The controller limits charging power to its rated capacity. An oversized PV array will not operate at maximum power point.
- **PV Short Circuit:** If a PV short circuit occurs, the controller stops charging. Remove the short circuit to resume normal operation.
- **PV Reverse Polarity:** Full protection against PV reverse polarity ensures no damage to the controller. Correct the connection to start normal operation.
- **Battery Over Voltage:** If other energy sources charge the battery, and the battery voltage exceeds 15.5V (for 12V system), 31.0V (for 24V), 46.5V (for 36V), or 62.0V (for 48V), the controller stops charging to prevent overcharging damage. (Note: "Stop charging" means charging current becomes very low).
- **Battery Over Discharge:** When battery voltage drops to the set low voltage disconnect point, the controller stops discharging to protect the battery from over-discharging.
- **Load Over Current Protection:** If the load current exceeds 1.25 times the maximum rated load current, the controller disconnects the load.
- **Load Short Circuit Protection:** If a load short circuit occurs, the protection activates automatically.
- **Over Temperature Protection:** The controller's fan will activate to reduce temperature. If the temperature exceeds safe limits, the controller will reduce power or shut down to prevent damage.

Image: Visual representation of various protection features including load short circuit, battery over-discharge, battery reverse polarity, PV short circuit, PV over current, battery overcharge, controller overheating, and load overload protection. Also shows internal components like copper coil transformer and capacitance.
Technical Specifications
| Feature | Specification (HHJ-60A) |
|---|---|
| Charging mode | 3-stage |
| Max. PV Input Power | |
| 12V system | 720W |
| 24V system | 1440W |
| 36V system | 2100W |
| 48V system | 2800W |
| Input Specification DC | |
| 12V system | 20V~80V |
| 24V system | 37V~105V |
| 36V system | 50V~160V |
| 48V system | 72V~160V |
| Battery Voltage Automatic Recognition | |
| 12V system | DC9V~DC15V |
| 24V system | DC18V~DC29V |
| 36V system | DC30V~DC39V |
| 48V system | DC40V~DC60V |
| Overcharging protection voltage | 60V |
| Limited current protection | 61A |
| Max efficiency | ≥98.1% |
| PV utilization | ≥99% |
| Protection Function | |
| Temperature protection | 75°C / 167°F |
| Fan-on temperature | >45°C / 104°F |
| Fan-off temperature | <40°C / 95°F |
| Properties | |
| Size (mm)/(in) | 214x115x50mm / 8.43x4.53x1.97in |
| Net weight(Kg)/(lb) | 1.1 / 2.43 |
| Gross weight(Kg)/(lb) | 1.2 / 2.65 |
| Electromagnetic compatibility | EN61000, EN55022, EN55024 |
| Enclosure | IP21 |
| Environmental temperature | -20°C ~ +55°C |
| Storage temperature | -40°C ~ +75°C |
User Tips
- **MPPT Performance:** Users confirm that this controller provides true MPPT functionality, working effectively with various panel configurations (e.g., three parallel 250W 39V panels).
- **Terminal Capacity:** The terminals are capable of clamping wires up to 6mm², which is suitable for currents up to 30A. Ensure your wiring matches the expected current for your setup.
- **LiFePO4 Battery Settings:** For LiFePO4 batteries, you may need to manually select the appropriate battery mode (e.g., 'b3' if available, or 'USE' for custom settings). Be aware that the default low voltage disconnect (LDV) might be programmed for lead-acid batteries, so adjust it if necessary for your LiFePO4 setup.
- **Versatile Application:** This controller is noted for its strong quality, good manufacturing, and suitability for small spaces, motorhomes, and low-consumption systems due to its practical and easy-to-handle design.
- **Initial Setup:** Some users have noted that manual selection of battery mode is required, especially for specific battery types like LiFePO4. Always verify and adjust settings after initial installation.
Warranty and Support
Warranty Regulations
- Within 30 days from the date of purchase, a faulty controller will be replaced free of charge under normal use (with authorization from technical personnel).
- Within 2 years from the date of purchase, a faulty controller will be repaired free of charge.
NOTE: Disassembling the unit privately voids the warranty.
Contact Information
For any questions or support, please contact:
- **Company:** SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- **Tel/Fax:** +86 755-28219903
- **Email:** support@powmr.com
- **Website:** www.powmr.com
- **Address:** Henggang Street, Longgang District, Shenzhen, Guangdong, China