1. Important Safety Instructions
WARNING: Carefully read and adhere to all safety instructions.
- Before installing and operating the controller, please read this user manual thoroughly and keep it for future reference.
- The installation or operation of the controller should only be performed by individuals who have received proper training and supervision.
- This controller product does not have user-serviceable components; do not disassemble or attempt to repair the controller yourself.
- Install the controller in a well-ventilated environment with adequate clearance around it.
- Install the controller on non-combustible walls and ensure there are no flammable materials nearby; it is normal for the controller to generate heat during operation.
- Place the controller in an environment that is protected from direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
- Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
- Do not place any objects on top of the controller.
- Install and charge batteries in well-ventilated or exhaust-ventilated environments.
- Ensure there are no open flames in the vicinity of the batteries, as batteries emit explosive gases.
- Battery acid is corrosive; if battery acid comes into contact with the skin, rinse immediately with clean water.
- Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
- Ensure that the equipment is properly configured for the type of battery connected to it.
2. Product Introduction
The PowMr MPPT Solar Charge Controllers (POW-M80-PRO and POW-M100-PRO series) represent cutting-edge innovation in solar technology. These controllers feature advanced CNC technology, an LCD screen, and user-friendly button design for real-time monitoring of operational data and system status. They support Maximum Power Point Tracking (MPPT) battery charging mode, maximizing energy utilization efficiency.
Designed for diverse solar systems, they automatically control battery charging and discharging, optimizing processes to extend battery life and enhance overall system performance. Equipped with self-diagnostic and electronic protection functions, they prevent damage during installation errors or system failures, ensuring reliability and stability.
These controllers offer expanded customization options for quicker system configuration. With a compact size, lightweight design, and a combination of air-cooling and natural heat dissipation using aluminum alloy backplates, they enhance operational safety, stability, and versatility. The parallel operation feature allows for easy expansion of solar energy sources.
The POW-M80-PRO and POW-M100-PRO provide high current charging up to 80A or 100A, ensuring efficient energy capture and storage. They are an ideal choice for efficient, sustainable, and secure energy management.
3. Key Features
- Integrated Charging Presets: Adaptive charging logic for flooded, gel-sealed, and lithium batteries.
- Versatile Application: Compatible with 12V/24V/36V/48V system voltages.
- Multi-Stage Charging Algorithm: Optimizes each charging cycle and maintains battery capacity.
- Maximum Power Point Tracking (MPPT) Technology: Tracks maximum power point voltage (Vmp) for optimal energy collection (up to 99.9% tracking efficiency, 97% peak conversion efficiency).
- Supports Up to 12 Units in Parallel: Allows for easy expansion of solar panel configuration and energy storage capacity.
- Adaptive Boost Charging: Monitors battery response to determine optimal boost stage duration, preventing overcharging.
- Durable and Secure: Includes photovoltaic input overcurrent, photovoltaic array short circuit, reversed photovoltaic polarity, battery overvoltage, battery overdischarge, and over-temperature protection.
- External Temperature Probe Configuration: Enhances precision in battery temperature monitoring for accurate temperature compensation.
- Forced Air Cooling: Built-in cooling fan for efficient heat dissipation.
- Lithium Battery Activation: Adjusts charging cycle for lithium batteries and activates protected lithium batteries using solar energy (current not exceeding protection voltage/current range).
4. Setup and Installation
4.1 Product Appearance
The controller features an LCD display screen, function keys, photovoltaic input interface, battery interface, temperature probe port, parallel communication port, port cover plate, and heat dissipation vent.

Front view of the PowMr MPPT Solar Charge Controller.

Bottom terminals of the controller with cover removed.

Rear view of the controller with heat sink.
4.2 Unpacking and Inspection
Before unpacking, inspect the packaging for any signs of damage. After unpacking, check the contents to ensure nothing is damaged or missing. The package should contain:
- Controller
- User Manual
- Installation screws
- Parallel connector
- External temperature sensor
4.3 Choosing the Installation Location
- Install the controller in a space with good natural ventilation/exhaust.
- Avoid direct sunlight.
- Ensure there is ample clearance around the controller. The minimum clearance at the top, bottom, and both sides is 75mm.
- Install the controller on a non-combustible wall and ensure no flammable materials are nearby.
- Install the controller in an environment that avoids direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
- Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries.
- When running multiple controllers in parallel, ensure they are installed at the same horizontal height, with a minimum spacing of 200mm between controllers.
4.4 Wiring Precautions
WARNING: Risk of Electric Shock! Before wiring, ensure that all power sources are turned off and follow the relevant inspection and operation procedures.
- Installation and wiring work should be carried out by a certified electrician.
- Wiring should follow the sequence: Battery > PV Input.
- To avoid short-circuits and polarity reversal, pay attention to connecting the positive (+) cable to the device's positive (+) terminal and the negative (-) cable to the device's negative (-) terminal.
- Loose and/or incomplete connections can lead to cable or terminal overheating. Therefore, tighten all cables to minimize transition resistance, using cable sizes appropriate for the specific circuit's current rating.
- For safety and compliance, the cables connected to the controller must have appropriate circuit breakers installed, ensuring tight connections.
- Ensure that all circuit breakers are in the off position before completing all wiring.
4.5 Installation and Wiring Guidelines
- Mount the Controller: Install the controller vertically with its ports facing downward, securing it to the wall through the four mounting holes using screws. Use two upper screws for initial "hanging" of the device, followed by the addition of two lower screws, and then fully tighten all four screws.
- Battery Wiring: Connect the battery to the controller using cables. Connect the positive cable terminal to the positive terminal port, and the negative cable terminal to the negative terminal port.
- PV Wiring: Connect the photovoltaic array to the controller using cables. The notes for battery wiring also apply to the PV ports.
- Temperature Probe Connection: Connect the temperature probe wire to the controller and securely fix the probe end to the battery using insulation tape.
- Pre-Startup Check: If all connections are accurate and securely connected, close the circuit breakers in the order of Battery and PV Input circuitry.
Video demonstrating the installation and wiring process for the solar charge controller.
5. Operating Guide
5.1 Operation Interface Overview
The LCD display provides various information about the system status. Key indicators include:
- Day/Night Indicator Icon: Indicates the presence of photovoltaic input.
- Battery Remaining Capacity Indicator: Shows the current battery charge level.
- Charging in Progress Indicator: Displays when the battery is being charged.
- Photovoltaic Input Voltage/Power/Operating Mode/Fault Codes: Shows PV array status and any error codes.
- Current Battery Voltage/Charging Current/Device Temperature/Battery Calibration Voltage/Parallel Communication Code/Battery Type/Boost Charging Voltage/Float Charging Voltage/MPP Tracking Return Voltage: Detailed battery and controller parameters.
5.2 Button Functions
The controller features three buttons: PV/SET, BAT/▲, and BAT/▼.
| Button | Mode | Description |
|---|---|---|
| PV/SET | Browsing Mode | Switch photovoltaic input parameters |
| Setup Mode | Confirm settings | |
| BAT/▲ | Browsing Mode | Short Press: Switch battery parameters, move to the next item |
| Setup Mode | Long Press: Enter battery parameter settings Increase value/return to the previous item and move to the next | |
| BAT/▼ | Browsing Mode | Switch battery parameters, return to the previous item |
| Setup Mode | Decrease value/return to the previous item | |
| Long press PV/SET and BAT/▲ simultaneously to restore factory settings. | ||
5.3 Battery Parameter Settings
The controller allows configuration of various battery-related parameters. In browsing mode, use the BAT/▲ and BAT/▼ keys to scroll through battery parameters. To adjust a parameter, long-press the BAT/▲ key to enter the setting mode. Use BAT/▲ and BAT/▼ to adjust values, then press PV/SET to save.
Calibrated Battery Voltage
If there is a difference between the controller's monitored battery voltage and a multimeter reading, you can calibrate it using this setting.
Parallel Communication Code Setting
In parallel operation mode, each controller must have a defined communication code (01-06). The device with the smallest code becomes the main controller. If the main controller fails, the system automatically designates the controller with the next code as the new main controller.
Default Parameters for Different Battery Types
The controller has preset charging parameters for various battery types. If 'USE' (User-defined) is selected, these parameters can be manually adjusted.
| Battery Type | FLd (Flooded) | GEL (Gel) | SEL (Sealed) | USE (User-defined) |
|---|---|---|---|---|
| Boost Charging Voltage | 14.6V | 14.2V | 14.4V | 9.0~17.0V |
| Float Charging Voltage | 13.8V | 13.8V | 13.8V | 9.0~17.0V |
| MPP Tracking Return Voltage | 13.2V | 13.2V | 13.2V | 9.0~17.0V |
Note: These values are for 12V batteries. For 24V/36V/48V systems, the range values are 2/3/4 times the specified range, respectively. The LCD screen only displays voltage values for 12V batteries.
Custom Configuration of Charging Voltage
If 'USE' is selected, you can manually set the following parameters:
- Nominal System Voltage (12V/24V/36V/48V)
- Boost Charging Voltage (9.0~17.0V)
- Float Charging Voltage (9.0~17.0V)
- MPP Tracking Return Voltage (9.0~17.0V)
Setting Steps:
- Use the BAT/▲ and BAT/▼ keys to select the parameter you want to set.
- Long-press the BAT/▲ key to enter the setting mode for the selected parameter.
- Use the BAT/▲ and BAT/▼ keys to adjust the voltage value.
- Press the PV/SET key to confirm and save.
Logic for setting custom battery voltage parameters: Maximum Charging Voltage > Boost Charging Voltage > Float Charging Voltage > MPP Tracking Return Voltage.
6. Parallel Operation Guide
The controller supports parallel operation for expanding solar panel configuration and energy storage capacity. Up to 12 units can be connected in parallel.
6.1 Parallel Operation Schematic

Diagram illustrating multiple controllers connected in parallel.
6.2 Main Modules in Parallel Setup
- Controller: Parallel controllers should be installed at the same horizontal level.
- Solar Array: Each controller must be connected to a separate solar array. One solar array cannot be simultaneously connected to more than one controller. The input power connected to each controller should not exceed the rated input power of a single controller.
- Battery Bank: All parallel controllers are connected to the same battery bank.
6.3 Parallel Installation and Wiring
- Install parallel devices at the same height level with a minimum distance of approximately 75mm between devices.
- Connect communication cables.
- Connect all parallel controllers to the same battery bank.
- Connect each controller to its respective photovoltaic array.
- After completing the wiring, power on by closing the battery circuit breaker. Once powered on, set the master and slave configurations as defined in the 'Parallel Communication Code Setting' section. Then, proceed to configure the entire parallel system through the master controller.
7. Maintenance
WARNING: Risk of electric shock! Before performing any maintenance, ensure that all power sources are turned off.
We recommend conducting the following checks and maintenance at least twice a year to ensure optimal performance:
- Ensure the controller is securely mounted in a clean and dry environment.
- Ensure proper airflow around the controller and clean any dust or debris from the heat sinks.
- Inspect all exposed wires for insulation damage, such as severe sun exposure, friction wear, dryness, insect or rodent damage. Repair or replace any damaged wires as necessary.
- Tighten all terminals and check for loose, broken, or burnt cable connections.
- Confirm that all system components are properly grounded.
- Ensure all terminals are free from corrosion, insulation damage, high temperatures, or signs of burning/discoloration, and tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. If present, clean promptly.
8. Troubleshooting
When a fault occurs, the controller will display a fault code to assist you in finding a solution.
| Fault Code | Possible Causes | Solutions |
|---|---|---|
| 18 | Low input photovoltaic voltage | Increase the number of solar panels or connect them in series to raise the photovoltaic input voltage. |
| 60 | Overtemperature protection | Allow the device to cool below the recovery temperature to resume normal charging and discharging. |
| 63 | High battery voltage | Measure and confirm if the battery voltage exceeds the rated voltage. If so, close the photovoltaic array circuit breaker. |
| 65 | Low battery voltage | Charge the battery until the voltage exceeds the undervoltage termination voltage. Refer to 'Default Parameters for Different Battery Types' for specific values. |
| 71 | High input photovoltaic voltage | Reduce the number of connected photovoltaic arrays to lower the photovoltaic input. |
| 73 | Overcharging current | Alternatively, modify the series and parallel connection to decrease voltage or current values. |
9. Specifications
| Parameter | POW-M80-PRO | POW-M100-PRO |
|---|---|---|
| Solar Input Specification | ||
| Max. Solar Array Open-Circuit Voltage | 160V | |
| Maximum Input Power (12V System) | 960W | 1200W |
| Maximum Input Power (24V System) | 1920W | 2400W |
| Maximum Input Power (36V System) | 2880W | 3600W |
| Maximum Input Power (48V System) | 3840W | 4800W |
| Battery Charging Specification | ||
| Charging Technology | MPPT | |
| Charging Algorithm | 3 Stages | |
| Nominal System Voltage | 12V/24V/36V/48V | |
| Battery Voltage Range | 9~60V | |
| Rated Charging Current | 80A | 100A |
| Maximum Efficiency | ≤98% | |
| MPPT Efficiency | >99% | |
| Temperature Compensation | -3mV/°C/2V (default) | |
| Self-Consumption | 44mA/12V; 26mA/24V; 18mA/36V; 12mA/48V | |
| Environment Specification | ||
| Operating Temperature Range | -35°C~+45°C | |
| Humidity Range | ≤95%, Non-condensing | |
| Altitude | <3000m | |
| General Specification | ||
| Protection Level | IP32 | |
| Dimensions | 260x180x75mm | 315x195x80mm |
| Net Weight | 2kg | 2.7kg |
10. User Tips
- Always double-check all wiring connections for tightness and correct polarity before powering on the system to prevent damage and ensure safety.
- Regularly monitor the controller's display for any fault codes and address them promptly using the troubleshooting guide.
- Ensure adequate ventilation around the controller to maintain optimal operating temperatures and prolong its lifespan.
- For optimal battery health, ensure the battery type setting on the controller matches your battery's specifications.
11. Warranty & Support
11.1 Warranty Declaration
Under the following circumstances, PowMr reserves the right not to assume any quality warranty responsibilities:
- Damage caused by improper transportation.
- Damage resulting from incorrect storage, installation, or usage.
- Damage caused by non-professionals or untrained personnel installing and operating the equipment.
- Damage resulting from non-compliance with the instructions and safety warnings in this document.
- Damage caused by operation in environments that do not meet the requirements specified in this document.
- Damage due to operation beyond the parameter ranges specified in applicable technical specifications.
- Damage resulting from unauthorized disassembly, product alteration, or software code modification.
- Damage caused by abnormal natural conditions (force majeure), such as lightning, earthquakes, fires, storms, etc.
- Any damage resulting from failure to adhere to local standards and regulations during the installation and operation processes.