1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Heltec 350A Relay Battery Management System (BMS). This BMS is designed to protect 3S-32S Lipo/LiFePO4 battery packs, offering robust protection features and enhanced functionality for various applications.

Key Features & Upgrades:

Important Upgrades and Features of Heltec Relay BMS

Diagram illustrating key upgrades and features of the Heltec Relay BMS.

  • Added Forced Start Function: Customers can connect an external expansion switch. Pressing for one second can force start for two minutes.
  • Built-in Pre-Charge Function: Soft start after turning on the switch to protect electrical equipment and the relay.
  • Power Soft Start Switch: After closing, there is no output, and safety protection does not continue to consume excess electrical energy.
  • Optimized Protection: Over-charging does not affect discharging, and over-discharging does not affect charging, effectively solving drawbacks of single relay protection boards.
  • Enhanced Relay Design: Updated relays with more powerful functions, compatible with inverters.

2. Setup and Installation

Proper installation is crucial for the safe and effective operation of your BMS. Please follow these steps carefully.

2.1 Pre-Installation Checklist:

  • Ensure the power switch on the protection board is turned OFF before installation.
  • Prepare your lithium battery pack (Lipo/LiFePO4) with consistent internal resistance and capacity.
  • Charge individual battery cells to full voltage before assembly.
  • Have a multimeter ready for voltage measurements.

2.2 Wiring Diagram:

Heltec Relay BMS Side View

Side view of the Heltec Relay BMS, showing connection points.

3-8S Relay Protection Board Same Port Wiring Diagram

Wiring diagram for 3-8S Relay Protection Board (Same Port).

2.3 Installation Steps:

  1. Assemble Lithium Battery Pack: Ensure all cells are balanced and at full voltage.
  2. Connect B-thick Wire: Connect the B-thick wire of the protection board to the negative terminal of the battery. This B-wire must be a thick short wire to ensure good contact.
  3. Connect Ribbon Cable:
    • Attention: Before connecting the ribbon cable, unplug it from the board first.
    • The first black wire on the far right of the cable is B0, which connects to the negative terminal of the battery.
    • The second cable B1 connects to the positive terminal of the first string of batteries.
    • The third cable B2 connects to the positive terminal of the second string of batteries.
    • Continue this pattern for B3, B4, and so on, connecting each to the positive terminal of the subsequent battery string. The wiring method is based on order, not color.
  4. Measure Cable Outlet: After connecting the ribbon cable, measure the voltage between every two adjacent ribbon cables, starting from the metal head of the black B0 ribbon cable, using a multimeter.
  5. Voltage Check & Activation:
    • The voltage of a polymer (ternary) battery should be less than 4.20V (recommended 4.15-4.20V).
    • The voltage of a lithium iron phosphate (LFP) battery should be less than 3.6V (recommended 3.4-3.6V).
    • After verifying accuracy, insert the ribbon cable into the protection board.
    • Turn on the power switch of the protection board and activate charging.
    • Use a multimeter to measure if the total voltage B- of the battery pack is equal to the output voltage C- of the protection board. The BMS will only work normally if these voltages are equal.
  6. Final Connection: Connect the negative terminal of the charger and the negative terminal of the load to C-. Assembly is now complete.

3. Operating Instructions

3.1 Strong Start Function:

Strong Start Function Description Diagram

Diagram illustrating the strong start function wiring.

The factory reserves a welding interface for the strong start function. If needed, install an unlocked switch (press to turn on, release to disconnect). If the battery is over-discharged or over-temperature protected, press and hold the switch for 1-5 seconds and then release it. This will force start the BMS for approximately 120 seconds.

3.2 Relay Operation:

Double Vacuum High-Voltage Relay and Application Fields

Image detailing the double vacuum high-voltage relay and its applications.

The BMS utilizes a dual vacuum high-voltage 500A relay. It consumes only 1.2 watts when activated. It supports continuous currents of 300-600 amperes and instantaneous surges of up to 2000 amps. The anti-arcing design handles both large and small currents effectively, featuring internal and external dual temperature control.

4. Maintenance

To ensure the longevity and optimal performance of your Heltec 350A Relay BMS, consider the following maintenance guidelines:

  • Regular Inspection: Periodically inspect all wiring connections for tightness and signs of corrosion or damage.
  • Cleanliness: Keep the BMS unit clean and free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning.
  • Environmental Conditions: Operate the BMS within its specified temperature and humidity ranges to prevent premature wear.
  • Firmware Updates: Check the official Heltec website for any available firmware updates that may improve performance or add features.

5. Troubleshooting

If you encounter issues with your BMS, refer to the following troubleshooting tips:

  • BMS Not Activating/No Output:
    • Check if the total voltage B- of the battery pack is equal to the output voltage C- of the protection board. If not, re-check all wire connections for errors.
    • Verify that individual string voltages are normal and that series connections are in good contact.
    • Attempt to activate by charging or by short-circuiting B- to C- for 5 seconds.
  • Battery Not Fully Charging or Premature Shutdown:
    • Ensure all battery cells have consistent internal resistance and capacity. Inconsistent cells can lead to incomplete charging or early protection shutdown due to high individual cell voltage.
    • If a single cell voltage is too high, charging may be prevented. If too low, the BMS may power off for protection.
  • BMS Not Supporting Serial Connection:
    • Note that this protective board does not support serial connection with another protective board.

6. Specifications

General:

  • Brand Name: Heltec
  • DIY Supplies: Electrical
  • Origin: Mainland China
  • High-concerned chemical: None
  • Electronic: No

Electrical Parameters:

Parameter Value (60A) Value (120A) Value (150A) Value (200A) Value (500A)
Standard Continuous Current 60A 120A 150A 200A 500A
Discharge Overcurrent Protection Data on temperature not exceeding 60°C for 5 minutes in an open area at room temperature of 20°C
Main Circuit Conduction Resistance 9mR 5mR 2mR 3mR
Charging Current (Same Port) 60A 120A 150A 200A 500A
Discharging Current (Same Port) 60A 120A 150A 200A 500A
Standard Charging Voltage NCM 4.2*strings | LFP 3.65*strings
Overcharge Protection (Active Balance Voltage) Forced Balance
Overcharge Detection Voltage NCM 4.235±0.03V | LFP 3.650±0.03V
Overcharge Threshold Voltage NCM ≥4.19V±0.03V | LFP ≥3.405V±0.03V
Overcharge Detection Delay 500-1500ms
Overcharge Release Voltage NCM 4.180±0.03V | LFP 3.550±0.03V
Balance Current 100-500mA
Overdischarge Voltage Protection Discharge Overcurrent Protection
Overdischarge Detection Voltage NCM 2.800±0.1V | LFP 2.350±0.1V
Overdischarge Detection Delay 500-1500ms
Overdischarge Release Voltage NCM 3.000±0.1V | LFP 2.550±0.1V
Short Circuit Protection Trigger Condition External load short circuit
Short Circuit Detection Delay 150-600ms
Temperature Control Protection Over temperature protection during charging and discharging: 75±5°C
High Temperature Release During charging and discharging: 75±5°C
Self Consumption (Work Power Consumption) Switch function
Working Temperature Range -30°C to 100°C

Physical Dimensions:

  • Length: 15 cm
  • Width: 15 cm
  • Height: 10 cm
  • Weight: 1.5 kg

Application Fields:

This BMS is suitable for a wide range of lithium battery applications, including but not limited to:

  • Electric bikes
  • Electric tricycles
  • Electric vehicles
  • Electric forklifts
  • Tourist sightseeing cars
  • RVs
  • Car starting thrusters
  • Photovoltaic inverters
  • And other lithium battery fields.

7. User Tips

  • Model Variations: Be aware that new and old models may be sent randomly. The updated versions feature two relays, more powerful functions, and an added force-start function, and are compatible with inverters.
  • Battery Cell Consistency: Always use battery cells with consistent internal resistance and capacity. Charge them to full voltage before assembly to prevent issues like incomplete charging or premature protection shutdowns.
  • Smart Features: While primarily a protection board, its advanced features like pre-charge and soft start contribute to a more robust and user-friendly battery system.

8. Warranty and Support

For detailed warranty information and technical support, please refer to the official product documentation or contact the manufacturer directly.

An official user manual in PDF format is available for download:

View User Manual (PDF)