1. Introduction and Product Overview
Thank you for purchasing the MC8 multi-checker. This device is a compact, versatile tool designed for hobbyists, featuring a bright, color IPS display with high accuracy.
Key Features:
- Measures and balances LiPo, LiHV, LiFe, and Lion batteries.
- Wide voltage input range: DC 7.0V to 35.0V.
- Supports Main, Balance, and Signal port power inputs.
- Measures and outputs PWM, PPM, and SBUS signals.
- Equipped with USB-A and USB-C dual-port output.
- USB-C port provides 20W PD fast charge output.
- Features battery over-discharge protection, automatically disabling USB output when battery reaches critical levels.
- Measurement and balance accuracy: <0.005V.
- Balance current: 60mA.
- 2.0-inch IPS full viewing angle display with 320*240 pixel resolution.
2. Safety Precautions
Please read and understand these safety precautions before operating the device.
- The operational voltage of the MC8 is between DC 7.0V and 35.0V. Ensure the polarity of the power source is not reversed prior to use.
- Do not operate the device under extreme heat, humidity, flammable, or explosive environments.
- Never leave the device unattended when in operation.
- Disconnect the power source when the device is not in use.
3. Product Layout and Components
Familiarize yourself with the various ports and controls of your MC8 Multi-Checker.
Figure 3.1: Front and Rear Layout of the MC8 Multi-Checker. Key components include the IPS Display, Signal port, Balance port, Main input (XT60), Output slider, Metal roller, USB-C port, and USB-A port.
- IPS Display: 2.0-inch color screen for displaying information.
- Signal Port: Used for signal measurement and output.
- Balance Port: Connects to battery balance leads for cell voltage monitoring and balancing.
- Main Input (XT60): Primary power input for the device, accepts 7-35V DC.
- Output Slider: Used to adjust channel output in signal output modes.
- Metal Roller: Navigates menus and options, also functions as a button (short/long press).
- USB-C Port: For 20W PD fast charging output and firmware upgrades.
- USB-A Port: For 5V 1A charging output and firmware upgrades.
4. Setup and First Use
- Connect the battery to the MC8's balance port, or connect a 5.0-35.0V power source to the XT60 input port.
- The screen will briefly show the boot logo for approximately 0.5 seconds.
- After booting, the device will enter the main interface, displaying cell voltage readings.
- Turn the metal roller to scroll between different menus and options.
- Short press the roller to select or enter an item; long press to confirm or activate certain functions.
- Use the output slider to adjust channel output when in relevant modes.
Figure 4.1: Main interface displaying cell voltage.
Tip: The scroller's function may vary depending on the specific menu item. Refer to the detailed instructions for each mode.
5. Operating Instructions
5.1. Voltage Test and Balancing
Individual Cell Voltage Display and Balance:
- Connect the balance port of your battery to the MC8.
- Upon powering on, the main page will show the voltage of each individual cell. The cell with the highest voltage is highlighted in red, and the cell with the lowest voltage is highlighted in blue. The total pack voltage and the voltage difference (highest voltage - lowest voltage) are also displayed.
- To start the balance function, press and hold the metal roller for more than 2 seconds from the main menu. The MC8 will use internal resistors to discharge cells until the pack achieves a uniform voltage (less than 0.005V difference between cells).
Important: The voltage bars are calibrated for LiPo batteries and may not be accurate for other battery chemistries. After balancing, remove the battery from the MC8 to prevent over-discharging.
Battery Pack Total Voltage:
Connect the main XT60 lead of your battery to the MC8's main XT60 input port. The device will display the total voltage of the battery pack.
Tip: The MC8 can display the total voltage of all battery chemistries operating within its input limits.
5.2. Signal Measurement
Tip: When using the signal measurement function, the signal port, balance port, and main input port can all supply power to the MC8.
PWM Signal Measurement:
After the device powers on, scroll right once on the metal roller to enter the 'Measure' mode. The screen will display the PWM signal type, current pulse width (e.g., 1500us), and the cycle/frequency (e.g., 20ms/50Hz).
PPM Signal Measurement:
While in PWM signal measurement mode, press down on the scroller and then scroll right until 'PPM' is displayed. The MC8 will then measure the PPM signal.
SBUS Signal Measurement:
From PWM signal measurement mode, press down on the scroller and scroll right until 'SBUS' is displayed. The MC8 will then measure the SBUS signal.
5.3. Signal Output
PWM Signal Output:
- With the MC8 powered on, scroll right twice on the roller to enter 'Output' mode.
- Press down on the scroller for 2 seconds to enter the signal output mode.
- You can change the output mode between manual and 3 automatic modes of varying speeds.
- Adjust the PWM signal output pulse width (range: 1000us-2000us). In manual mode, push the channel output slider to change the width. In automatic mode, the signal width will automatically increase or decrease.
- Adjust the PWM signal output cycle (range: 1ms-50ms).
Important: If the cycle is set to less than 2ms, the maximum width will not exceed the cycle value. The channel output slider is safety protected; there will be no signal output until the slider is returned to its minimum position first.
PPM Signal Output:
- From the PWM output page, short press on 'PWM' to change the output type.
- Scroll right until 'PPM' is displayed, then short press to confirm the PPM selection.
- In the PPM output page, press down on the roller for 2 seconds to set the output value of each channel.
Important: The throttle channel can only be controlled using the signal from the output slider; its value cannot be changed using the roller for safety reasons. Ensure the output slider is at its lowest point prior to performing any tests.
SBUS Signal Output:
- From the PWM output page, short press on 'PWM' to change the output type.
- Scroll right until 'SBUS' is displayed, then short press to confirm the SBUS selection.
- In the SBUS output page, press down on the roller for 2 seconds to set the output value of each channel.
Important: Similar to PWM output, if the cycle is set to less than 2ms, the maximum width will not exceed the cycle value. The channel output slider is safety protected; there will be no signal output until the slider is returned to its minimum position first.
5.4. USB Charging
The MC8 features built-in USB ports for charging mobile devices on the go.
Figure 5.1: USB-A and USB-C charging ports.
- The USB-A port supplies 5V 1A output.
- The USB-C port supplies 20W fast charging, supporting protocols such as PD3.0, QC3.0, AFC, SCP, and FCP.
Important: When charging USB devices, always connect the balance port of the battery to the MC8. If any individual cell voltage drops to 3.0V or below, the USB output will automatically stop to prevent battery damage.
6. Calibration
To enter calibration mode, press and hold the metal roller while powering on the MC8.
Calibration Procedure:
- Measure the voltage of a fully-charged battery pack using a high-accuracy multimeter.
- Use the roller to select 'Input' on the MC8 screen.
- Scroll the roller until the displayed value on the MC8 matches the voltage measured by your multimeter.
- Scroll down to the 'Save' option and press down on the roller to save the calibration for the main input.
- Repeat this process for each individual cell (1-8) if needed, comparing the MC8's reading with your multimeter.
- When finished, scroll to the 'Exit' option and press down on the roller to exit calibration mode.
- 'Defau.' option allows you to return to default factory settings.
Important: Only use multimeters with 0.001V accuracy to perform calibrations. If your multimeter is not accurate enough, do not perform calibration, as this could lead to incorrect readings.
7. Specifications
| Category | Parameter | Value |
|---|---|---|
| General | Main input port | XT60 7.0V-35.0V |
| Balance input | 0.5V-5.0V Lixx 2-8S | |
| Signal port input | <6.0V | |
| Balance current | MAX 60mA @2-8S | |
| Balance accuracy | <0.005V @ 4.2V | |
| USB | USB-A output | 5.0V@1.0A firmware upgrade |
| USB-C output | 5.0V-12.0V @MAX 20W | |
| USB-C protocol | PD3.0 QC3.0 AFC SCP FCP | |
| Measurement | PWM | 500-2500us @20-400Hz |
| PPM | 880-2200us*8CH @20-50Hz | |
| SBUS | 880-2200us *16CH @20-100Hz | |
| Output | PWM | 1000-2000us @20-1000Hz |
| PPM | 880-2200us*8CH @50Hz | |
| SBUS | 880-2200us *16CH @74Hz | |
| Product | Size | 68mm*50mm*15mm |
| Weight | 50g | |
| Package | Size | 76mm*60mm*30mm |
| Weight | 100g | |
| LCD | IPS 2.0 inch 240*240 resolution | |
8. User Tips
- The MC8 is highly functional, serving as a battery checker, servo tester, signal generator, signal analyzer, battery balancer, and even a power bank, all in a compact size.
- No additional power source is needed for basic battery checking; simply connect it to the balancer port.
- For FPV drone users, connecting the battery via XT60 allows the MC8 to function as a charger via its Type-C port.
- The device is excellent for checking cell balance and making minor adjustments to off-balance cells.
- Some users have noted the text on the screen can be small, which might be challenging for those with presbyopia.
9. Troubleshooting
- Device Not Powering On: Ensure the battery or power source is connected correctly and within the specified voltage range (DC 7.0V-35.0V). Check for correct polarity.
- Inaccurate Voltage Readings: Verify that your battery is properly connected to the balance port or XT60 input. If you suspect calibration issues, refer to Section 6 for calibration instructions, using a highly accurate multimeter.
- USB Charging Not Working: Ensure a battery is connected to the balance port. The USB output will automatically stop if any individual cell voltage drops below 3.0V to protect the battery.
- Unusual Smells on First Use: A few users have reported a slight unusual smell when first connecting the device. If this persists or is accompanied by smoke or excessive heat, disconnect the device immediately and contact support.
- Signal Measurement/Output Issues: Double-check all connections for signal ports. For signal output, ensure the output slider is at its minimum position before starting tests, as it is safety protected.
10. Warranty and Support
The ToolkitRC MC8 Multi-Checker comes with a standard manufacturer's warranty against defects in materials and workmanship. Please retain your proof of purchase for warranty claims.
For further assistance, technical support, or warranty inquiries, please visit the official ToolkitRC website or contact your retailer:
- Official Website: www.toolkitrc.com
Please refer to the official website for the most up-to-date warranty information and support resources.