Mastfuyi FY511D

Contents

MASTFUYI Digital Earth Resistance Tester

Model: FY511D

Brand: Mastfuyi

1. Introduction

This manual provides essential information for the safe and effective operation of your Mastfuyi FY511D Digital Earth Resistance Tester. Please read it thoroughly before use and retain it for future reference. The FY511D is designed for high-precision ground resistance and ground voltage measurements, suitable for EV charging piles, electrical grounding tests, and lightning protection systems.

Front view of the Mastfuyi FY511D Digital Earth Resistance Tester, highlighting the measuring range of 0.01Ω to 2000Ω and key features like 3-range selector and data retention.
Front view of the Mastfuyi FY511D Digital Earth Resistance Tester, highlighting the measuring range of 0.01Ω to 2000Ω and key features like 3-range selector and data retention.

2. Safety Information

This instrument must only be installed and operated by qualified personnel in compliance with safety precautions, technical specifications, and applicable laws and safety standards. Operating electrical equipment involves hazardous voltages. Failure to observe warnings may result in severe injury or equipment damage.

Warning ▲

  • Before measuring, ensure the rotary switch is set to the correct position and test leads are fully inserted.
  • Do not use the instrument in circuits with voltages exceeding 600V AC/DC to ground.
  • Avoid using the instrument near explosive gases, vapors, or dust.
  • Do not connect test leads or grounding rods when the instrument or hands are wet.
  • Do not touch test leads or grounding rods during measurement.
  • Do not open the battery cover during measurement.
  • Do not perform measurements under abnormal conditions (e.g., damaged casing, exposed metal parts).
  • Do not install replacement parts or modify the instrument. Return damaged units to an authorized dealer for repair.
  • Turn the rotary switch to "OFF" and remove test leads before opening the battery cover.
  • Do not replace batteries when the instrument is wet.
  • Do not replace batteries during measurement. To avoid electric shock, switch the rotary switch to the "off" position and remove the test leads before replacing the batteries.

Caution ⚠

  • Remove batteries if the instrument will not be used for an extended period.
  • Avoid exposing the instrument to direct sunlight, high temperatures, humidity, or condensation.
  • Clean only with a neutral detergent or damp cloth. Do not use abrasives or solvents.
  • Ensure the instrument is dry before storage.
  • Do not mix new and old batteries. When installing, pay attention to the direction of the positive and negative poles of the battery and do not install them backwards.

3. Key Features

  • Measures interference voltage.
  • Measures grounding resistance for various equipment (e.g., high-voltage towers, buildings, electrical systems, mobile communication base stations, transmitters).
  • Monitors and plans lightning protection systems.
  • Measures resistance using auxiliary grounding electrodes.
  • Smart microcontroller for high reliability and precision.
  • Supports both two-pole and three-pole measurement modes.
  • Large-screen LCD digital display with backlight for easy readability.
  • Data storage capability: stores 20 sets of measurement data, retained even during power loss.
  • Equipped with an auto-shutdown function.

4. Product Overview

4.1 Panel Description

Mastfuyi FY511D Earth Resistance Tester connected for measurement, showing H/C Auxiliary Earth Electrode and S/P Auxiliary Earth Electrode connections.
Mastfuyi FY511D Earth Resistance Tester connected for measurement, showing H/C Auxiliary Earth Electrode and S/P Auxiliary Earth Electrode connections.
  • ACV Jack: Ground voltage input.
  • E Jack: Connects to the grounding electrode.
  • S/P Jack: Connects to the auxiliary grounding electrode.
  • H/C Jack: Connects to the auxiliary grounding electrode.
  • Measurement indicator light: Indicates measurement status.
  • Measurement button: Press or rotate 90° to start measurement.
  • Range selector knob: Used to select measurement functions and ranges.
  • Backlight and data recording read button: Activates backlight and accesses stored data.
  • LCD screen: Displays measurements, units, and prompts.

4.2 Display Symbols Legend

Close-up of the FY511D's LCD display showing measurement results and symbols like H, S, E, 3POLE, and MEMO.
Close-up of the FY511D's LCD display showing measurement results and symbols like H, S, E, 3POLE, and MEMO.
  • TEST: Measurement indicator
  • LIMIT: Overrange
  • MAX: Maximum values
  • MIN: Minimum values
  • REL: Relative measurement
  • MEMO: Data storage
  • 2POLE: Two-Pole resistance measurement mode
  • 3POLE: Three-Pole resistance measurement mode
  • V: Volts (voltage)
  • Ω: Ohms (resistance)
  • kΩ: Kilo-ohms (resistance)
  • AC symbol: Alternating Current
  • Warning symbol: Indicates caution.
  • Low battery indicator: Indicates low battery.
  • Socket identifier: Identifies connection points.
  • AVG: Average value
  • READ: Data reading
  • USED: Stored data

5. Operating Instructions

5.1 Ground Voltage Measurement

Warning: Do not apply voltages exceeding 600V during ground voltage measurement. High voltage is output during grounding resistance measurement (E, S/P, or H/C ports). Avoid electric shock.

Rotate the selector switch to the "ACV" position. Insert the test leads into the E and ACV jacks. Connect the other ends of the test leads in parallel to the voltage source or load for measurement. The voltage value will be displayed on the LCD.

Mastfuyi FY511D Earth Resistance Tester set up for ground voltage measurement, showing the connection of test leads to the E and ACV jacks.
Mastfuyi FY511D Earth Resistance Tester set up for ground voltage measurement, showing the connection of test leads to the E and ACV jacks.

5.2 Two-Pole Ground Resistance Measurement (Simplified)

This method uses existing grounding electrodes with known minimum grounding resistance as auxiliary grounding electrodes (e.g., metal water pipes, commercial power supply common grounding, or building lightning rods).

  1. Detect the grounding voltage first: Measure the voltage to ground before grounding resistance measurement. If the grounding voltage is present and exceeds 10V, disconnect the power supply to the object to be measured and wait until the ground voltage drops before measuring.
  2. Measurement of grounding resistance: Turn the rotary switch to any position between 20Ω-2000Ω. S/P and H/C need to be shorted. Connect the instrument to the device to be measured. Press the "Measurement knob key" to start the measurement. The measurement indicator lamp lights and flashes, then automatically stops. The measured value is automatically maintained on the display.
  3. Calculate the grounding resistance value: The measured value Re is the sum of the grounding resistance of the auxiliary grounding pole (re) and the real grounding resistance (Rx). So, Rx = Re - re.

5.3 Three-Pole Ground Resistance Measurement (Precise Measurement)

This instrument uses the potential difference method. It measures the grounding resistance value by flowing AC rated current I between the measured object E (grounding electrode) and H/C (current electrode), and measuring the potential difference V between E and S/P (voltage electrode).

Detailed view of the FY511D's rotary selector switch, illustrating the three resistance measurement ranges (20Ω, 200Ω, 2000Ω) and ACV settings.
Detailed view of the FY511D's rotary selector switch, illustrating the three resistance measurement ranges (20Ω, 200Ω, 2000Ω) and ACV settings.
  1. First check the ground voltage: Before measuring, measure the voltage to ground. If it exceeds 10V, disconnect the power supply and wait for the voltage to drop.
  2. Measurement of grounding resistance: Drive the P auxiliary grounding rod and C auxiliary grounding rod into the ground in a straight line at intervals of 5 to 10 meters from the device under test. Connect the test lines (black, red, green) from the E, S/P, and H/C ports of the instrument to the device under test, auxiliary grounding rod P, and auxiliary grounding rod C, respectively. Turn the rotary switch to any position between 20Ω-2000Ω. Press the "Measurement Knob button" to start the measurement. The measurement indicator light will illuminate and flash, then turn off, and the measured value will be automatically retained on the display.

Note: Insert auxiliary grounding rods into moist soil. If the measured value exceeds the range (LIMIT 20000 displayed), check for loose test leads or high auxiliary grounding resistance. Ensure test leads are separated to avoid measurement errors.

5.4 Reading Measurement Data

The instrument allows you to view stored historical measurement data.

  1. In standby mode, press and hold the "Record" key to enter the data reading interface. The "READ" indicator will appear.
  2. Press the "Record" key briefly to view the data storage.
  3. Press and hold the "Record" key again to exit the data storage interface.

5.5 Backlight

Press the backlight button to turn the backlight on or off. The backlight must be turned on or off manually.

6. Specifications

General Specifications

  • Measurement Method: Ground resistance is measured using the constant current conversion method (approx. 800 Hz, 3 mA). Ground voltage is measured using the average value rectification method.
  • Operating Temperature and Humidity: 0~40°C, relative humidity below 85%.
  • Storage Temperature and Humidity: -10~50°C, relative humidity below 85%.
  • Power Supply: 1.5V AA batteries (Not included). External DC 9V power adapter jack (500mA~5A) is also available.
  • Dimensions: 173 x 123 x 60 mm.
  • Weight: Approximately 448g (excluding batteries).

Technical Specifications

Accuracy: ± (as of reading + digits), with a one-year warranty period. Reference Conditions: Ambient temperature 18°C~28°C, relative humidity not exceeding 80%.

Measurement TypeRangeAccuracyResolution
Ground Resistance0-20Ω±(3%+3 digits)0.01Ω
20-200Ω±(3%+3 digits)0.1Ω
200-2000Ω±(3%+3 digits)1Ω
Ground Voltage0V-600V (50/60HZ)±(1%+5 digits)1V

7. Maintenance

Battery Replacement

The instrument can be powered by 1.5V AA batteries (not included) or an external DC 9V power adapter.

Close-up of the Mastfuyi FY511D showing the DC 9V power adapter jack for external power supply.
The FY511D can be powered by batteries or an external DC 9V power adapter (500mA~5A).
  1. Unscrew the fastening screw on the battery cover of the instrument and remove it.
  2. Replace the old batteries, paying attention to the direction of the battery electrodes marked on the bottom of the battery case.
  3. Cover the battery cover and tighten the screw.

8. Troubleshooting

If you encounter issues with your FY511D, consider the following:

  • "LIMIT 20000" displayed: This indicates that the measured value is out of range, or the auxiliary grounding resistance value is too high. Check if test wires are loose, or if the auxiliary grounding rods are properly inserted into moist soil.
  • Inaccurate readings: Ensure the rotary switch is set to the correct position. Verify test lead connections are secure and not tangled. Check for high ground voltage (above 10V) before resistance measurements and address it if present.
  • Instrument not powering on: Check battery installation and ensure batteries are not depleted. If using an external power adapter, ensure it meets the DC 9V 500mA~5A specification.
  • No display/backlight: Check power supply. If the backlight is off, press the backlight button to activate it.

9. User Tips

  • Always perform a ground voltage check before conducting resistance measurements to ensure accurate results and safety.
  • For precise ground resistance measurements, ensure auxiliary grounding rods are placed in moist soil. If the soil is dry, moisten the area around the rods.
  • Keep the instrument and accessories clean and dry to prolong their lifespan and ensure reliable operation.

10. Packing List

The standard package for the Mastfuyi FY511D Earth Resistance Tester includes:

Contents of the FY511D Earth Resistance Tester package, including the main unit, carrying case, test probes, test leads, grounding rods, and user manual.
Contents of the FY511D Earth Resistance Tester package.

11. Warranty and Support

The Mastfuyi FY511D Earth Resistance Tester comes with a one-year warranty period for accuracy. For technical support, service, or warranty claims, please contact your authorized dealer or the manufacturer directly. Always refer to the official user manual for the most up-to-date information and support contacts.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.