1. Product Information

1.1 General Description

This series of electrical products are mainly used in circuits of AC 50/60 Hz, with a rated insulation voltage up to 690V. They are designed for remote switching, circuit control, motor starting, protection, and automatic control applications.

These contactors are widely used in power distribution cabinets, automation equipment, machinery, machine tools, building electrical systems, and industrial control systems. They offer stable performance, safe operation, and reliable control.

1.2 Compliance Standards

  • GB 14048.1
  • GB 14048.4
  • IEC 60947-4-1
  • GB 21518
  • GB/T 14048 series

1.3 Main Technical Parameters

Parameter Value
Rated operational voltage AC 24V ~ 415V
Rated insulation voltage 690V
Rated impulse withstand voltage 6kV ~ 8kV
Degree of protection IP20 or higher
Mechanical endurance Up to 8,000,000 operations
Electrical endurance Up to 1,200,000 operations
Mounting type DIN rail mounting / screw fixing
Connection type Screw clamp terminals
Main Circuit Rating Current 38A (varies by model, e.g., 9A, 18A, 32A, 50A, 65A)
Phase 3
Number of Pole 3
Electricity Type AC
Certification CE
Number of main contacts Three Poles
Pole number 3P
Arc extinguishing medium Air type
Secondary contact form 1NO+1NC
Major contactor form Silver dot
Application Field Terminal power distribution
Coil voltage 220V, AC (available in 24V, 36V, 110V, 220V, 380V)

1.4 Terminal Identification

  • Main circuit: L1, L2, L3 (line side); T1, T2, T3 (load side)
  • Control coil: A1, A2
  • Auxiliary contacts: NO (normally open), NC (normally closed)
External construction of an AC contactor LC1D25
Figure 1: External Construction of LC1D25 AC Contactor
Key components include: Main contact (Inlet hole), Screw mounting hole, Auxiliary contact, Coil, and Product information QR code.
Product structure diagram of an AC contactor LC1D09
Figure 2: Product Structure Diagram of LC1D09 AC Contactor
This diagram highlights the Main contact (Inlet hole), Standard rail, Coil wiring terminal, Auxiliary contact, Screw mounting hole, Anti-counterfeit query code, Product information QR code, and Main contact (Outlet hole).
LC1D09 AC Contactor with specifications
Figure 3: LC1D09 AC Contactor Overview
Shows the LC1D09 AC Contactor with specifications: 9A, 3 Normally Open main contacts, 1 Normally Open and 1 Normally Closed auxiliary contact, 4kW rated power, and available coil voltages (AC24V/36V/110V/220V/380V).

2. Instructions for Use

2.1 Installation Conditions

  • Ambient temperature: -5°C ~ +40°C
  • Altitude: ≤ 2000m
  • Environment: Must be free from explosive hazards, corrosive gas, conductive dust, and be dry and well-ventilated.
  • Installation: Shall be firm, stable, and free from vibration.

2.2 Wiring Instructions

  1. All wiring work must be performed with ALL POWER DISCONNECTED.
  2. The rated voltage of the product must match the actual control voltage.
  3. All wiring terminals must be securely fastened.
  4. Wrong connection, short circuit, or loose connection is strictly prohibited.

2.3 Operation

  • Use within the rated voltage, current, and specified utilization category.
  • Long-term overload operation is strictly forbidden.
  • Use with supporting protective devices such as circuit breakers and relays.
  • No abnormal noise, odor, or excessive heating should occur during operation.

3. Maintenance

  • Regular inspection and maintenance must be carried out under power-off conditions.
  • Replace damaged or worn parts in time.
  • Live maintenance, disassembly, or modification is prohibited.

4. Safety Warnings

4.1 General Safety Requirements

  • This product shall be installed, operated, and maintained only by qualified electricians.
  • Always disconnect all power sources and verify voltage absence before any operation.
  • Improper installation, wiring, or use may cause electric shock, fire, equipment damage, or personal injury.

4.2 Warning Statements

  • **DANGER: High voltage may cause fatal electric shock. Disconnect, test, and ground before working!**
  • WARNING: Live working may lead to electric shock, burns, or death!
  • WARNING: Overload operation may cause fire or equipment failure!
  • WARNING: Wrong wiring may cause short circuit, electric shock, or damage!
  • CAUTION: Stop operation immediately if abnormal noise, odor, or heating occurs!

4.3 Safety Symbols

  • ⚡ Warning: Risk of electric shock
  • 🔥 Warning: Risk of fire
  • 🚫 Do not work live
  • 🧤 Wear insulating protection
  • 🔌 Disconnect and test voltage before operation
  • 🛠️ Do not disassemble or modify without approval
Exploded view of contactor showing safety features
Figure 4: Internal Components and Safety Features
Highlights features such as flame retardant materials, clear circuit distinction, mirror contacts, strong seismic resistance, lower noise design, and robust wiring terminals.

5. Limitations of Use

  • Do not use beyond rated voltage, current, frequency, or service conditions.
  • Do not use in flammable, explosive, highly corrosive, high-dust, or high-humidity environments.
  • Do not use exceeding the specified utilization category or duty type.
  • Do not disassemble, modify, or replace internal components without authorization.
  • Do not force operation with faults or damage.
  • Installation, commissioning, and maintenance must be performed by qualified electrical personnel.

6. Troubleshooting

This section provides general guidance for common issues. For complex problems, consult a qualified electrician.

  • Contactor Fails to Energize: Check control circuit voltage, coil continuity, and auxiliary contact status. Ensure all wiring is secure.
  • Contactor Overheats: Verify that the load current does not exceed the contactor's rated current. Check for loose connections or incorrect coil voltage. Ensure proper ventilation.
  • Abnormal Noise: Inspect for mechanical obstructions, worn parts, or incorrect mounting. Ensure the contactor is firmly installed.
  • Intermittent Operation: Check for loose wiring connections, unstable control voltage, or issues with auxiliary contacts.

7. User Tips

No specific user tips were available from provided reviews or Q&A. However, general best practices for electrical components include:

  • Always ensure the correct coil voltage is applied to prevent damage or malfunction.
  • Regularly check terminal connections for tightness to avoid overheating and poor performance.
  • Consider the environmental conditions (temperature, dust, humidity) to ensure the contactor operates within its specified limits.
  • When replacing an old contactor, ensure the new unit has matching specifications (current rating, voltage, contact configuration) for safe and effective operation.

8. Additional Resources

Product Overview Video

Play video
Watch video online

This video provides a visual overview of the Schneider Electric TeSys Deca series, highlighting features such as green packaging, modular design, easy installation with multi-standard screw designs, suitability for harsh environments, and high reliability.

User Manual (PDF)

A detailed user manual in PDF format is available for download. This document contains comprehensive information on installation, operation, and technical specifications.

Reference: View User Manual (PDF)

9. Warranty and Support

For warranty information, please refer to the terms and conditions provided by your seller or contact Schneider Electric customer support directly. Keep your purchase receipt for any warranty claims.

For technical support or further assistance, please contact Schneider Electric's official support channels.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.