Introduction
Thank you for purchasing the UNIWEIGH Digital Pocket Scale! This user guide is designed to help you quickly set up and operate your scale. Scales are precision instruments and require proper care and skill to achieve the best results. For any questions or support, please contact our customer support at support@uniweigh.com.
What's in the Box
Please check the package contents to ensure all items are present:
- UNIWEIGH Digital Pocket Scale
- 2x AAA Batteries
- User Manual
Key Descriptions
- ON/OFF Button: Turns the scale ON and OFF.
- MODE Button: Changes the weighing unit (g, oz, ozt, dwt, ct, gn).
- TARE Button: Zeros the scale. Also subtracts the weight of an empty container (Tare Function).
Setup
Battery Installation
- Open the battery cover located on the underside of the scale.
- Insert the 2x AAA batteries into the battery compartment, ensuring correct polarity (+/-).
- Close the battery cover securely.
Operating Instructions
Weighing Your First Item
- Press the ON/OFF button to turn the scale on.
- Place the item to be weighed on the center of the weighing platform.
- Read the weight from the display.
Tare Function
The Tare function allows you to subtract the weight of a container, so the display only shows the net weight of the contents.
- Place an empty tray or container on the weighing platform.
- Press the TARE button to subtract the container's weight. The display will show '0.00'.
- Add items to the container to see their weight on the display.
Note: The weight of the container will subtract from the available capacity and may show a negative value if the container is removed. Press TARE again to reset the display to zero.
Unit Conversion
To change the weighing unit, press the MODE button. The scale supports the following units: grams (g), ounces (oz), troy ounces (ozt), pennyweights (dwt), carats (ct), and grains (gn).
Auto-Off Function
The scale features an automatic shut-off function to conserve battery life. It will turn off after 3 minutes of inactivity. You can also manually turn it off by pressing the ON/OFF button.
To adjust the auto-off time:
- Turn off the scale.
- Press and hold the MODE button, then quickly press the ON/OFF button 5 times. The display will show "180".
- Release both buttons. Press the MODE button to cycle through auto-off times: "0" (disables auto-off), "60", "120", "180" seconds.
- Once the desired time is selected, press the ON/OFF button to confirm. The display will show "PASS", indicating the setting is saved.
Calibration
Your scale is factory-calibrated, and most users will not need to calibrate it frequently. However, periodic checks with calibration weights are recommended to ensure accuracy.
Important: Calibration adjustment is permanent and should only be performed using accurate calibration weights (e.g., 50g) that match the scale's requirements. Do not use coins or other household items for calibration.
- Ensure you have the required 50g calibration weight.
- Place the scale on a flat, level surface and allow it to adjust to room temperature.
- Press ON/OFF to turn the scale on and wait for it to stabilize (display shows '0.00').
- Ensure nothing is on the weighing platform. Long press the MODE button until the display shows "CAL".
- Press the MODE button again. The display will flash the required calibration weight (e.g., "50.00").
- Carefully place the 50g calibration weight on the center of the platform.
- The display will show "PASS" and then return to normal weighing mode, indicating successful calibration.
Important Considerations & Things To Avoid
- Unlevel Surfaces: Always use the scale on a stable, level surface for accurate readings.
- Radio Frequency Interference: Avoid using the scale near devices that emit strong radio frequencies, as this can affect accuracy.
- High Humidity: Protect the scale from excessive moisture and high humidity.
- Air Currents: Strong air currents can cause unstable readings, especially for very light items.
- Vibration: Ensure the weighing environment is free from vibrations.
- Extreme Temperatures: Avoid extreme hot or cold temperatures. Allow the scale to acclimate to room temperature before use.
Specifications
| Feature | Detail |
|---|---|
| Model | P2-200-BLU |
| Max Capacity | 200.00 g / 7.054 oz / 6.43 ozt / 128.60 dwt / 1000.00 ct / 3086.4 gn |
| Readability | 0.01 g / 0.001 oz / 0.001 ozt / 0.01 dwt / 0.05 ct / 0.2 gn |
| Weighing Units | g, oz, ozt, dwt, ct, gn |
| Overall Dimensions | 5.7 in x 3.4 in x 0.94 in |
| Platform Dimensions | 3 in x 2.3 in |
| Display Dimensions | 1.65 in x 0.78 in |
| Calibration Weight | 50g |
| Power | 2 x AAA Batteries |
| Warranty | 2 Year Limited Warranty |
Troubleshooting
- Inaccurate Readings: Ensure the scale is on a flat, stable surface, away from drafts or vibrations. Recalibrate the scale if necessary using a precise 50g calibration weight.
- "Lo" Display: Indicates low battery. Replace the AAA batteries.
- "O-Ld" Display: Indicates overload. Remove items immediately to prevent damage to the scale.
- Unstable Display: Check for air currents, vibrations, or electromagnetic interference. Ensure the item is centered on the platform.
User Tips
- For consistent results, always use the scale on a very stable and level surface.
- The scale provides accurate measurements even for very small quantities, making it suitable for various precise tasks.
- The clear LCD display and intuitive button layout make the scale easy to use for all users.
- The robust construction and hinged cover offer good protection, making it suitable for portability.
Warranty and Support
This UNIWEIGH Digital Pocket Scale comes with a 2-Year Limited Warranty.
For technical support, warranty claims, or any other inquiries, please contact UNIWEIGH customer support at support@uniweigh.com.
A detailed user manual in PDF format is also available for download: View User Manual (PDF).
Product Demonstration Video
Watch this video for a visual guide on how to use your UNIWEIGH Digital Pocket Scale, including unit conversion, calibration, taring, and weighing various items.