SARIK DL2-WLTE-T/TVC

Contents

4G LTE Smart Controller DL2-WLTE-T/TVC User Manual

Model: DL2-WLTE-T/TVC

1. Product Overview

The 4G LTE Smart Controller DL2-WLTE-T/TVC is a versatile remote control device designed for automating various equipment and systems. It features a 30A relay output, allowing it to control high-power devices via SMS, phone calls, or a dedicated mobile application (WLTE Control). The controller also supports temperature monitoring with sensor linkage, enabling automated actions based on temperature thresholds and providing alerts. It is suitable for applications such as home appliance control, industrial automation, agricultural systems, and door openers.

DL2-WLTE-TVC 4G Remote Controller with key features highlighted
Figure 1: DL2-WLTE-TVC 4G Remote Controller highlighting 30A relay output, dial/SMS control, web control, app control, temperature linkage, and power failure SMS alert.
Global control via 4G LTE network
Figure 2: Illustration of unlimited distance 4G global control, allowing equipment control and SMS alarms from anywhere.

2. Key Features

  • 4G LTE SIM Card Support: Requires a local 4G SIM card for operation.
  • 30A Relay Output: Two channels capable of controlling high-power equipment (up to 3KW for AC motors, 6600W for resistive loads per channel).
  • Multiple Control Methods: Control via SMS, phone calls, dedicated mobile App (WLTE Control), and web interface.
  • Temperature Sensor Linkage: Monitors real-time temperature (-40℃ to 120℃), triggers relay actions based on set limits, and sends temperature alarm messages.
  • Timing Control: Supports up to 24 groups of timing schedules for automated operations.
  • Short-time Trigger Switch (Inching): Suitable for controlling electric gates or garage doors with a brief relay pulse (1 to 9 seconds settable).
  • Power Failure Alarm (DL2-WLTE-TVC only): Sends SMS/APP/Email alerts upon power failure or restoration.
  • Email and APP Notifications: Receive alerts for temperature changes and device status.
  • Wide Application: Ideal for home automation, industrial control, agriculture, remote base stations, and more.

3. Specifications

Table 1: Product Parameters
Parameter Value
DC Power Supply Standard adapter DC12V/500mA
Power Consumption Standby 12V/50mA, working Max 12V/200mA
4G Frequency (LTE-FDD) B1/B3/B5/B7/B8/B20
GSM Frequency 900/1800mhz
SIM Interface Micro SIM card
Antenna Interface Standard SMA interface
Temperature Sensor Interface 1 sensor port
Temperature Detection Range -40℃ to 120℃
Relay Outputs 2 channels, 30A/250VAC, 30A/125VAC
Output Logic Normally open and normally closed
Shell Size 115mm x 90mm x 40mm
Box Size 150mm x 150mm x 50mm
DL2-WLTE-T Gross Weight 300g
DL2-WLTE-T Net Weight 190g
DL2-WLTE-TVC Gross Weight 310g
DL2-WLTE-TVC Net Weight 200g
Detailed product parameter table for DL2-WLTE-T and DL2-WLTE-TVC controllers
Figure 3: Comprehensive table of controller specifications for both T and TVC versions.

4. Safety Information

  • Ensure the power supply voltage matches the device's requirements (DC 7-36V).
  • Always disconnect power before installing or wiring the device to prevent electric shock.
  • Handle the SIM card carefully during insertion and removal.
  • Do not expose the device to extreme temperatures outside its operating range (-40℃ to 120℃).
  • Keep the device away from water and high humidity environments.
  • For high-power applications, ensure proper wiring and use appropriate contactors as shown in wiring diagrams.

5. Package Contents

The standard package for the DL2-WLTE-T version typically includes:

  • DL2-WLTE-T 4G Remote Controller
  • Antenna
  • USB Cable
  • (Note: The 'With Adpt' versions include a DC12V power adapter.)
DL2-WLTE-T controller and accessories
Figure 4: DL2-WLTE-T version shown with included antenna and USB cable. Note that the T version does not include the power failure alarm function.

6. Setup Guide

6.1 SIM Card Installation

  1. Ensure the device is powered off.
  2. Locate the Micro SIM card slot on the device.
  3. Insert your Micro SIM card into the slot. If your SIM card has a PIN code, please disable it before inserting.
  4. Push the SIM card until you hear a 'ticking' sound, indicating it is securely in place.
  5. To remove, push the SIM card again, and it will pop out.
SIM card insertion diagram
Figure 5: Diagram illustrating the process of inserting and removing the Micro SIM card.

6.2 Power Connection

Connect a DC 7-36V power supply to the 'Power in DC 7-36V' terminals. For models including an adapter, use the provided DC12V adapter.

6.3 Network Connection

After powering on, observe the SIG indicator LED:

  • One flash per second: The device is entering the GSM network.
  • One flash in two seconds: The device has successfully connected to the 4G network. APP control is only available when connected to the 4G network.
  • SIG LED always on: This indicates no access to the network. Check the SIM card installation and antenna connection. The issue might also be with the SIM service.

6.4 APN Configuration

APN (Access Point Name) settings are crucial for network access. The factory default APN is 'internet' with empty username and password. If your local network requires different APN settings, you must configure them.

To check current APN settings, send the SMS command: SN0000CHECK (assuming default password '0000'). The device will reply with its current APN, user, and password.

To set a custom APN, use the following SMS command format:

SN+password+APN+length of APN=APN content, length of user=user content, password length=password content.

Example: For APN: datelo.com.br, user: algar, password: 12345, send:

SN0000APN13=datelo.com.br,05=algar,05=12345

To set APN, user, and password to null, send:

SN0000APN00=0,00=0,00=0

6.5 Physical Installation

The controller supports both DIM35mm industrial rail installation and screw installation.

Installation methods and dimensions
Figure 6: Installation methods including DIM35mm industrial rail and screw installation with device dimensions (115mm x 90mm).

7. Operation

7.1 SMS Control

You can control the device by sending SMS commands from any mobile phone, provided the password is correct. The default password is '0000'.

Table 2: SMS Commands
Function Message Format Description
Setup New Password SN0000NEW1234 SN + password(4 numbers) + NEW + new password.
Setup Authorized Number (up to 99 groups) SN0000SET09#13700000000 SN + password(4 numbers) + SET + **(Serial Number)+#Phone number. The serial number is the position to store the authorized number, from 01-99.
Inquiry Authorized Number SN0000CNK09 SN + password(4 numbers) + CNK + **(Serial Number)
Remove Authorized Number SN0000DEL09 SN + password(4 numbers) + DEL + **(Serial Number)
Remove ALL Authorized Numbers SN0000DELALL SN + password(4 numbers) + DEL + ALL
Control Relay ON SN0000ON SN + password(4 numbers) + ON
Control Relay OFF SN0000OFF SN + password(4 numbers) + OFF
Control Relay Status SN0000COMNF SN + password(4 numbers) + COM+N/F/X (N:Turn on; F:Turn off; X:Ignore)
Setup Trigger Time SN0000L01T0001 SN+password+L+01+T+length (length: 1-1000 seconds), 001 second is default
Control Relay Trigger SN00000TGCC SN + password(4 numbers) + OTG + C/X (Status: C:trigger; X:ignore)
Activate Feedback SMS when Input Action SN0000RLO SN + password(4 numbers) + RLO. (RLO is only valid after APP input control is set and push is activated)
Disable SMS Replies when Input Action SN0000RLC SN + password(4 numbers) + RLC
Enable Power-off Reminder SMS (DL2-WLTE-TVC only) SN0000DLO This command is only for DL1-WLTE-TVC
Disable Power-off Reminder SMS (default) SN0000DLC This command is only for DL1-WLTE-TVC
Setting Temperature Control (Up to 8 groups) SN0000LEA01P00256NF SN + password(4 numbers) + LE/GR + A + Group number (01-08) + P/N + -)+*****(*****is the Thousands, hundreds, tens, ones and decimal + 1Relay code(N/F/X)+2Relay code
JOG Relay via Dialing (pulse relay for few seconds, then return to initial state) SN0000TXO SN + password(4 numbers) + TXO
Invert Relay via Dialing (default) SN0000TXC SN + password(4 numbers) + TXC
Any Phone Can Control Device SN0000DIO SN + password(4 numbers) + DIO
Only Authorized Number Can Access Device (default) SN0000DIC SN + password(4 numbers) + DIC
Enable Dial Control Feedback SMS (default) SN0000CBO SN + password(4 numbers) + CBO
Disable Dial Control Feedback SMS SN0000CBC SN + password(4 numbers) + CBC
Power-off Memory ON (default) SN0000PAM SN + password(4 numbers) + PAM
Power-off Memory OFF SN0000PAF SN + password(4 numbers) + PAF
SMS control examples
Figure 7: Visual representation of SMS control for various devices like electric heaters and water pumps.

7.2 APP Control

The WLTE Control App provides a convenient and intelligent way to manage your device. Ensure the device is connected to the 4G network (SIG LED flashes once every two seconds).

Default App Password: 1234

The app allows for device control, timing management, sensor recording, input control, push notifications, operation records, and equipment location.

WLTE Control App interface
Figure 8: Screenshots of the WLTE Control App interface, showing login, device list, and control options.
App features: 30A relay, temperature control, timing
Figure 9: App features including 30A relay output, temperature control with notifications, and timing control for up to 24 groups.
App features: power failure alarm, email pushing, app pushing
Figure 10: App features for DL2-WLTE-TVC including power failure alarm, email pushing for temperature alerts, and general app push notifications.

7.3 Web Control

The device can also be controlled via a web browser on a PC, offering centralized management of your equipment.

Web control interface on a laptop
Figure 11: Web interface for centralized control of equipment via a PC browser.

7.4 Wiring Diagrams

Refer to the following diagrams for various application wiring scenarios:

Wiring diagrams for various applications
Figure 12: Wiring diagrams for connecting the controller to a low power lamp, DC motor, high-power AC motor (with contactor), electronic lock, and for controlling DC and three-phase motors in forward and reverse directions.

8. Troubleshooting

  • SIG LED always on: This indicates no network access. Check the SIM card installation, ensure the antenna is properly connected, and verify that the SIM card service is active.
  • App control not working: Ensure the device's SIG LED is flashing once every two seconds, indicating a successful 4G network connection. If not, check APN settings.
  • No SMS feedback: Check the V.KT command settings for phone number length if you are experiencing issues with SMS feedback. Ensure the correct country code and phone number length are configured.
  • Device not responding to commands: Verify the SIM card has credit and is active. Ensure the correct password is used in SMS commands.
  • Factory Reset: To reset the system, long press the SW2 button for 8 seconds until the SIG indicator flashes five times.

9. User Tips

  • For optimal performance, ensure the device is placed in an area with good 4G signal strength.
  • Regularly check the SIM card's balance to ensure uninterrupted service for SMS and data communication.
  • When using the temperature control feature, calibrate the sensor if necessary and set appropriate thresholds to prevent false triggers.
  • Utilize the timing control feature for energy saving and automated routines, such as turning on heaters before arrival or managing irrigation schedules.
  • For garage door control, the short-time trigger (inching) function provides a convenient and secure way to operate the door remotely.

10. Warranty and Support

This product typically comes with a 1-year warranty from the store. For any quality problems or technical support, please contact the seller directly. All inquiries are usually answered within 24 hours.

11. App Download

The WLTE Control App is available for both Android and iPhone devices. You can download it by scanning the QR codes below or by using the provided URLs:

You can also find an APP usage guide at: https://drive.google.com/file/d/1lAsjC6kF0n4FiM0RdYcbw5BZrFFJVlJy/view?usp=drive_link

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.