SONGGER ZJPVC-LCD-DN15-DN80

Contents

Digital PVC Flow Meter with LCD Display RS485 User Manual

Model: ZJPVC-LCD-DN15-DN80

1. Introduction

This product is an inline pipe-mounted digital flow meter designed for measuring the flow of water and compatible chemical liquids. It is manufactured with corrosion-resistant PVC material and features an LCD display for real-time flow visualization. The meter supports RS485 Modbus RTU communication, making it suitable for industrial monitoring, irrigation systems, and water treatment applications. The device is intended for full-pipe liquid flow conditions and indoor installation environments.

Some product configurations may not be fully listed due to page limitations. If you have specific requirements or customization needs, feel free to contact the manufacturer directly.

This product is a PVC-LCD digital flow meter designed for pipe sizes ranging from DN15 to DN80. Please note that the display screen is not waterproof—ensure proper dust and water protection during use. It is not recommended for outdoor installation.

2. Safety Information and Precautions

2.1. General Precautions

  • The LCD display is not waterproof. Additional dustproof and waterproof protection must be applied if used in humid environments. Outdoor installation is not recommended.
  • Do not exceed the rated pressure, temperature, or voltage limits, as this may result in damage or inaccurate readings.
  • Avoid strong vibration, direct sunlight, and rapid temperature changes during operation.
  • If the flow rate is too low, the device may not output a valid signal.

2.2. Warning Information

WARNING!

  • This product operates with DC electrical power. Improper wiring may cause electric shock or equipment damage.
  • The device is intended for liquid flow measurement only. Do not use with gas or explosive media.
  • The display unit is not waterproof and must be protected from water ingress.
  • Keep out of reach of children.

3. Specifications

General Parameters
Parameter Description
Working Voltage 10~30VDC
Working Current 60mA Max (30VDC)
Measurable Liquids Water or chemical liquids
Working Pressure 5kg/cm² (approx. 0.5 MPa)
Response Time Real-time
Protection Level IP65 (excluding the display surface)
Operating Temperature -10°C~70°C
Instantaneous Flow Range (LPM) 0~999.99
Total Flow Accumulation Range (FTM) 0~999999
Instant Flow Output Mode (Non-display) NPN pulse (150mA Max)
Total Flow Output Mode (Non-display) NPN pulse (150mA Max)
Communication Interface (Display type) RS485 using Modbus RTU protocol
Housing Material UPVC
Measurement Accuracy ±5% under specified conditions
K-value User-adjustable for calibration purposes

3.1. Pipe Diameter Selection

Confirm pipe size before ordering. Buyer covers return shipping for incorrect size.

Model Inner Diameter / Outer Diameter PVC Pipe
DN15 ID: 20.3mm / OD: 27mm
DN20 ID: 25.4mm / OD: 32mm
DN25 ID: 32mm / OD: 40mm
DN32 ID: 40mm / OD: 49mm
DN40 ID: 50mm / OD: 63mm
DN50 ID: 63mm / OD: 74.5mm
DN65 ID: 75.5mm / OD: 88mm
DN80 ID: 90.5mm / OD: 102mm

3.2. RS-485 Communication Series Flow Range (with Display + Control + Remote Transmission)

Model Flow Range Material
DN25 20-280L/min UPVC
DN32 40-460L/min UPVC
DN40 50-750L/min UPVC
DN50 60-1160L/min UPVC
DN65 80-1980L/min UPVC
DN80 100-3000L/min UPVC

3.3. Product Features

  • High Accuracy (±5%) – Delivers reliable and precise flow measurement for various applications.
  • Customizable K-Value – Adjustable flow coefficient allows fine-tuning for specific system requirements.
  • Multiple Unit Options – Supports total and pulse output in liters, gallons, or kiloliters to match your preference.
  • Alarm Function – Configurable open/close status and delay settings for immediate flow alerts.
  • RS-485 Communication – Enables remote data monitoring and system integration for enhanced control.
  • Durable Construction – Built with UPVC material, offering excellent resistance to acids, alkalis, and corrosion for long-term use.
  • Instantaneous flow meter alarm output status: (Normally Open/Normally Closed)
  • Instantaneous flow meter alarm output delay time is adjustable.
  • Instantaneous and total flow meter alarm outputs are configurable.
  • Equipped with RS-485 communication function.
  • Total flow meter unit options: (L/Gal/KL)

4. Installation

4.1. Pre-Installation Checks

  • Confirm that the pipe diameter matches the meter specification.
  • Ensure that the liquid to be measured is compatible with PVC material.
  • Ensure the pipeline is clean and free from debris before installation.

4.2. Physical Installation

Install the flow meter inline with the arrow direction aligned with the actual flow direction. Full-pipe liquid flow must be maintained during operation for accurate readings.

Diagram showing correct and incorrect installation positions for the flow meter
Figure 1: Correct Installation Positions. Ensure the meter is installed horizontally or vertically with flow direction matching the arrow, and always in a full pipe.

4.3. Wiring Guide

Connect the power supply according to the rated voltage range (10-30VDC). For RS485 models, connect the communication lines following Modbus RTU wiring conventions.

Wiring diagram for LCD & Digital Version and Non-Display Sensor
Figure 2: Wiring Method Diagram.

LCD & Digital Version Wiring:

  • Brown: Power Positive (10-30VDC)
  • Gray: RS-485 (-)
  • Yellow: RS-485 (+)
  • Blue: Power Negative
  • Black: Total Flow FTM/OP2 Output Control
  • White: Instant Flow LPM/OP1 Output Control

Non-Display Sensor Wiring:

  • Red (IN): Connect to Positive
  • Yellow (OUT): Signal Output Line
  • Black (GND): Connect to Negative

5. Operation

5.1. Power On and Initialization

Power on the device and allow it to initialize. The LCD will display instantaneous and total flow values.

5.2. Display Interface and Settings

The digital display version shows current instantaneous flow, instant flow rate set value, and liquid temperature. Buttons are available for setting and adjustment.

Digital Display Version interface showing flow rate, set value, temperature, and button functions
Figure 3: Digital Display Interface and Controls.
  • SET Key: Used to enter or confirm settings.
  • F Key / Left Adjustment Key: Used for function selection or left adjustment.
  • Down Adjustment Key: Used to decrease values or navigate down.
  • Up Adjustment Key: Used to increase values or navigate up.

If required, adjust the K-value and unit settings through the display interface according to the application requirements.

During operation, keep the flow rate within the specified measurement range to ensure valid signal output. Low flow may cause signal loss. Ensure full-pipe flow for best performance.

6. Storage and Maintenance

  • Store the product in a dry, well-ventilated environment when not in use.
  • Clean the exterior of the meter using a soft cloth. Do not use corrosive cleaning agents.
  • For long-term storage, disconnect the power supply and ensure the internal flow path is dry.
  • Periodic inspection is recommended to verify stable signal output and secure electrical connections.

7. Troubleshooting

This section provides general troubleshooting tips. For specific issues not covered here, please refer to the contact information for support.

  • No Signal Output: Check power supply, wiring connections, and ensure the flow rate is within the specified measurement range. Ensure full-pipe flow.
  • Inaccurate Readings: Verify K-value settings, ensure proper installation (aligned with flow direction, full pipe), and check for debris in the pipeline.
  • Display Not Working: Check power supply and connections to the display unit. Ensure the operating temperature is within the specified range.

8. User Tips

No specific user tips were available from reviews or Q&A. However, based on product features and common usage:

  • Always double-check pipe compatibility (inner and outer diameter) before purchasing to avoid installation issues.
  • For applications involving corrosive chemicals, regularly inspect the PVC housing for any signs of degradation.
  • When integrating with other systems via RS485, ensure correct Modbus RTU addressing and communication parameters are configured.

9. Applications

The Digital PVC Flow Meter is suitable for a wide range of applications, including:

  • Water Purification – Provides precise flow control to enhance the efficiency of filtration systems.
  • Electroplating Cleaning – Suitable for monitoring chemical flow in industrial cleaning processes.
  • Single Crystal Silicon Cleaning – Ensures reliable performance in sensitive semiconductor cleaning operations.
  • Ultrafiltration & Reverse Osmosis – Optimized for advanced filtration systems requiring accurate flow measurement.
  • Agricultural Irrigation – For monitoring water flow in irrigation systems.
Various industrial and agricultural applications of the flow meter, including water purification, cleaning processes, and irrigation
Figure 4: Wide Range of Applications.

10. Compliance Disclaimer

Disposal of this product must comply with the WEEE Directive and local EU regulations for electronic waste.

Note: The above warning information is for reference only. Final warning language must comply with the official language and regulatory requirements of the destination EU country.

This document is provided for product instruction purposes only. It does not constitute legal or regulatory compliance advice. The seller is responsible for ensuring that the product and documentation comply with all applicable EU directives and standards in the destination market.

11. Frequently Asked Questions (FAQs)

Q1: Is the display waterproof?
A1: No, the display is not waterproof. Ensure adequate dust and moisture protection.
Q2: Can it be used outdoors?
A2: It is not recommended for outdoor use due to the lack of waterproof protection.
Q3: What pipe sizes are compatible?
A3: Compatible with DN15 to DN80 PVC pipes. Ensure correct inner and outer diameters.

© 2024 SONGGER. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.