SWEVY SW6004

Contents

SWEVY SW6004 Digital Sound Level Meter User Manual

Model: SW6004

1. Introduction

The SWEVY SW6004 Digital Sound Level Meter is a high-precision instrument designed for accurate measurement of sound levels and ambient temperature. It is widely used in various fields including noise engineering, quality control, health care, environmental monitoring, and general applications in homes, offices, schools, and construction sites.

For a detailed visual guide, please refer to the official user manual PDF: SWEVY SW6004 User Manual (PDF)

2. Product Overview

The SW6004 features a color screen display, a wide measurement range, and various functions for comprehensive noise analysis.

SWEVY SW6004 Digital Sound Level Meter showing main features

Figure 1: SWEVY SW6004 Digital Sound Level Meter with key features highlighted.

Front view of the SWEVY SW6004 Digital Sound Level Meter

Figure 2: Front view of the SW6004.

2.1. Components and Controls

Dimensions and labeled parts of the SW-6004

Figure 3: SW-6004 Dimensions and Labeled Parts.

  1. Microphone and Windscreen: Captures sound. The windscreen reduces wind noise.
  2. Main Unit Display Screen: Liquid crystal color screen for displaying measurements and settings.
  3. ON/OFF Key (Power Button): Turns the device on or off.
  4. MODE Key: Toggles between data hold (MAX/MIN/Real-time) and alarm setup modes.
  5. UNIT Key: Switches temperature units (°C/°F) and increases values during alarm setup.
  6. SET Key: Enters/exits alarm setup mode and saves settings.
  7. Up/Down Arrows: Used for navigation and adjusting values in setup modes.

2.2. Microphone Technology

Close-up of the 1/2 inch condenser capacitive microphone

Figure 4: Capacitive Microphone with High-Precision Sensor.

The SW6004 utilizes a 1/2-inch Electret Condenser Microphone with a high-precision sensor and a 3-layer sensitive conductive layer, ensuring fast and accurate measurements.

3. Setup

3.1. Battery Installation

  1. Locate the battery door on the back of the unit.
  2. Open the battery door.
  3. Insert three (3) AAA size batteries into the compartment, ensuring correct polarity (+/-).
  4. Close the battery door securely.
  5. If the battery power indicator on the screen shows empty, replace with new batteries for optimal performance.

3.2. Calibration

The SW6004 unit is factory-calibrated before shipping. For professional use or if you suspect inaccuracies, it can be calibrated using a 94dB@1KHz calibrator. It is recommended to calibrate the unit once per year.

  1. Turn on the unit and allow it to enter normal measurement mode.
  2. Insert the 1/2-inch ECM microphone into the hole of the calibrator.
  3. Turn on the sound calibrator and set it to 94dB.
  4. Using a small screwdriver, adjust the trimmer in the calibration hole until the screen displays 94.0 dB.

4. Operating Instructions

4.1. Power On/Off

  • Power On: Press the ON/OFF key. The LCD screen will display all segments for 1 second, then enter normal sound level measurement mode.
  • Power Off: Press and hold the ON/OFF key until the LCD screen turns off.

4.2. Data Hold (MAX/MIN/Real-time)

  • In normal measurement mode, press the MODE key to cycle through:
    1. MAX: Displays the maximum measured sound level.
    2. MIN: Displays the minimum measured sound level.
    3. Real-time: Returns to current sound level display.
  • The screen will show "HOLD" icon along with "MAX" or "MIN" icon when active. Press MODE again to release the hold function.

4.3. Temperature Unit Selection (°C/°F)

  • In normal measurement mode, press the UNIT key to switch between Celsius (°C) and Fahrenheit (°F).

4.4. High and Low SPL Alarm Setup

  • In normal measurement mode, press the SET key once to enter alarm setup mode (Low Alarm then High Alarm).
  • Use the MODE key to decrease the alarm value, and the UNIT key to increase it. Long press for faster adjustment.
  • Press SET again to save the setting and exit.
  • Low Alarm Range: 30dB to 99.9dB. If the measured value is lower than the set low alarm, the screen will flash vertically to alert you.
  • High Alarm Range: 100dB to 130dB. If the measured value is higher than the set high alarm, the screen will flash vertically to alert you.

4.5. Auto or Manual Power Off Setup

  • In normal measurement mode, press and hold the MODE key for more than 3 seconds to enter power off setup.
  • Use the ON/OFF key to select "Auto OFF" or "Manual OFF".
  • Press and hold the MODE key for more than 3 seconds again to save and exit.
  • Auto OFF: The unit will power off after 5 minutes of inactivity.
  • Manual OFF: The unit will remain on until manually powered off.

4.6. Alarm ON/OFF

  • In normal measurement mode, press and hold the SET key for a few seconds to toggle the alarm function ON or OFF. The screen will show "Alarm" icon when ON.

4.7. Operational Demonstration Video

Video 1: Demonstration of the SWEVY SW6004 Digital Sound Level Meter in various environments and showcasing its functions.

5. Maintenance

5.1. Storage

  • Do not store the device in environments with high temperature or high humidity.
  • Avoid storing in areas with high concentrations of salt or sulfur.

5.2. Battery Care

  • If the instrument will not be used for a long period, remove the batteries to prevent leakage and damage.
  • Replace batteries promptly when the low battery indicator appears.

5.3. Usage Tips

  • When measuring sound pressure levels outdoors, always cover the ECM microphone with the provided wind shield ball to minimize wind noise interference.
  • Ensure the environmental sound level pressure is lower than the sound source being measured for accurate readings.

6. Troubleshooting

  • Device does not turn on: Check if batteries are installed correctly and have sufficient charge. Replace batteries if necessary.
  • Inaccurate readings: Ensure the microphone is clean and unobstructed. Verify that the wind shield is properly installed if measuring outdoors. Avoid strong electromagnetic interference.
  • Display issues: If the screen is blank or flickering, try replacing the batteries. If the problem persists, contact support.
  • Alarm not working: Ensure the alarm function is turned ON in the settings. Verify that the alarm thresholds are set correctly.

7. Specifications

ParameterValue
Measurement Range30 - 130 dBA
Measurement Accuracy±1.5dB (reference SPL point at 94dB@1KHz)
Resolution0.1dB
Frequency WeightingA
Frequency Range31.5Hz - 8.0KHz
Sampling Rate2 times/second
Data HoldMaximum and Minimum hold
Digital Display4 digit
Temperature Measurement Range-10°C ~ 50°C (14°F ~ 122°F)
Temperature Measurement Accuracy±2°C
Temperature Resolution0.1°C
Microphone1/2 inch Electret Condenser Microphone
Power SupplyAAA size battery x 3 pcs
Low Battery WarningYes
Weight148g
CertificationsCE, RoHS

8. User Tips

  • Regular Battery Check: Always ensure fresh batteries for consistent and accurate performance, especially before critical measurements.
  • Environmental Awareness: Be mindful of external factors like wind, humidity, and temperature, as they can influence readings. Use the windscreen outdoors.
  • Stable Positioning: For best results, hold the meter steady and point the microphone directly towards the sound source.
  • Understanding Alarms: Familiarize yourself with setting and interpreting the high and low alarm thresholds to quickly identify noise levels outside your desired range.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.

© SWEVY. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.