1. Introduction
Thank you for choosing the SWEVY Digital Coffee Concentration Meter, Model SW22C. This device is designed for precise measurement of Total Dissolved Solids (TDS) in coffee, helping you achieve optimal brewing consistency. It features a digital display, high accuracy, and a robust waterproof design for reliable performance in various environments.

Figure 1: SWEVY Coffee Concentration Meter highlighting key features: TDS range 0~22%, Accuracy ±0.2%, IP67 waterproof level, and Temperature compensation function.
Key Features:
- TDS Measurement Range: 0~22%
- High Accuracy: ±0.2%
- Resolution: 0.1%
- IP67 Waterproof and Moisture-Proof Certification
- Automatic Temperature Compensation
- Fast Response Speed: Generates data in under 5 seconds
- High-Precision Sample Cell

Figure 2: The device is IP67 certified, indicating it is waterproof and moisture-proof, suitable for use in wet kitchen environments.
2. Specifications
The following table details the technical specifications of your SWEVY Digital Coffee Concentration Meter:
| Feature | Specification |
|---|---|
| Model Number | SW22C |
| Brand Name | SWEVY |
| DIY Supplies | Plumbing |
| Origin | Mainland China |
| Certification | CE, RoHS |
| TDS Range | 0-22% |
| Accuracy | ±0.2% |
| Resolution | 0.1% |
| Temperature Compensation | 10-40°C |
| Applicable Temperature Range | 10-40°C |
| Ambient Temperature | 10-40°C |
| Battery | Built-in lithium battery (600mA) |
| Battery Included | No (refers to external/removable batteries) |
| Battery Life (Full Charge) | About 20,000 times |
| Product Dimensions | 114*58*31mm (L*W*H) |
| Size and Weight | 112(L)*54.8(W)*30.8(H) mm, 113g |
| High-concerned chemical | None |
3. Setup
Before first use, familiarize yourself with the device components and ensure it is adequately charged.

Figure 3: Front view of the SWEVY Digital Coffee Concentration Meter, showing the display, measurement slot, and control buttons.
3.1. Parts Identification
Refer to the diagram below for the main components of your refractometer:

Figure 4: Overview of the Digital Refractometer, including parts diagram, specifications, and operational instructions. For detailed view, please refer to the official PDF manual.
- Protective cover: Covers the prism and measuring slot.
- LCD: Digital display for readings and status.
- Measuring solution: Area where the sample is placed.
- Measuring slot: The well where the coffee sample is applied.
- Zero key (清零 Zero): Press for 1 second to zero the device.
- Prism: Optical component for measurement.
- Switch key (Power button): Press for 1 second to switch the device on or off.
- USB charging interface: For charging the built-in battery.
3.2. Initial Charging
Before first use, ensure the device is fully charged using the provided USB cable. Connect it to a 5V charger or computer USB port. Warning: USB charging voltage should not exceed DC6V limit.
4. Operating Instructions
4.1. Power On/Off
Press the Switch key (power button) for 1 second to turn the device on or off.
4.2. Language Selection
To switch between Chinese and English interface, hold down both the Switch key (power button) and the Zero key (清零 Zero) simultaneously when powering on the device.
4.3. Zero-Setting (Calibration)
It is crucial to zero-set the instrument with clean water or pure water to 0.0% before measuring. If it is not 0.0%, follow these steps:
- Open the protective cover.
- Drip about 0.3 ml of clean water or pure water into the measuring slot, ensuring it forms a layer of about 1 mm thickness.
- Press the MEAS key (测量 Meas).
- Check if the measured value on the LCD is 00.0%.
- If the value is not 00.0%, press the Zero key (清零 Zero) for 1 second to reset it to 0.0%.
- Clean the measuring slot thoroughly after zero-setting.
4.4. Measurement Procedure
After successful zero-setting, you can proceed with measuring your coffee sample.

Figure 5: The device provides fast response, generating data in under 5 seconds for quick and efficient measurements.
- Prepare your coffee sample. Ensure it is free from large particles.
- Clean the measuring slot thoroughly and dry it with a soft, lint-free cloth.
- Drip about 0.3 ml of your coffee solution into the measuring slot, ensuring it forms a layer of about 1 mm thickness.
- Close the protective cover gently.
- Press the MEAS key (测量 Meas) to display the TDS value.
- Record the displayed value.
- After measurement, clean the measuring slot immediately.
4.5. Cautions During Measurement
To ensure accurate readings, observe the following:
- Cold or Hot Measuring Solution: If your coffee sample is significantly colder or hotter than the ambient temperature, drop the solution into the measuring slot and wait for at least 20 seconds before taking a reading. This allows the instrument and solution to reach a stable temperature for accurate compensation.
- Measuring Solution Containing Suspended Substances: Suspended particles can interfere with light transmission and lead to inaccurate readings.
- Step 1: Remove as many suspended solids as possible from your coffee solution using a filter spoon or fine gauze.
- Step 2: Mix the measuring solution evenly. Do not use metal or hard objects, and avoid scratching the optical prism. Uneven solutions or suspended solids can cause measurement uncertainty.

Figure 6: The high-precision sample cell is equipped with advanced image processing algorithms and an ultra-narrow filter to block external light, ensuring accuracy.

Figure 7: Automatic temperature compensation reduces measurement errors caused by temperature differences, ensuring more accurate results.
5. Maintenance
5.1. Cleaning the Measuring Slot
Proper cleaning is essential for maintaining accuracy and extending the life of your device.
- General Cleaning: If there is dirt in the measuring slot or if the instrument has not been used for a long time, it should be cleaned before use.
- Cleaning Oily Residues: If the measuring slot contains oily residues and is not easy to clean, please clean it with ethanol or soapy water.
- Rinsing: After cleaning with ethanol or soapy water, drip clean water into the slot and wash with paper towels more than three times. Always discard the used towels after each wipe to prevent cross-contamination.
- Drying: Ensure the measuring slot is completely dry before storage or next use.
5.2. Storage
When the instrument is not in use, please store it in a place that is dry and away from direct sunlight or extreme temperatures.
6. Troubleshooting (Status Notice)
The device may display error messages or exhibit certain behaviors. Refer to the table below for common issues and their solutions:
| Error Message / Status | Reason | Solution |
|---|---|---|
| Cover with hand | External light is too strong to measure. | Move to a less brightly lit area or shield the sensor from direct light. |
| High temperature | Temperature excess in measuring slot. | Allow the device and sample to cool down to the operating temperature range (10-40°C). |
| Low temperature | Temperature excess in measuring slot. | Allow the device and sample to warm up to the operating temperature range (10-40°C). |
| Re zero | Zero-clearing step required. | Please follow the zero-clearing steps again (Section 4.3). |
| Less solution | Too little solution in measuring slot. | Add sufficient sample (approx. 0.3 ml) to cover the prism. |
| Less water | Too little clean water in measuring slot (during zero-setting). | Add sufficient clean water (approx. 0.3 ml) for zero-setting. |
| Out of range | Excessive concentration. | The sample concentration exceeds the device's measurement range (0-22% TDS). |
| Low voltage | Battery is low. | Charge the device with a 5V charger or computer USB. |
| Call maintenance | Possible damage to components. | If other troubleshooting steps fail, contact customer support. |
7. User Tips
- Consistency is Key: For comparable results, always try to measure coffee samples at a similar temperature and preparation state.
- Cleanliness: Always clean the measuring slot thoroughly before and after each use to prevent residue buildup and ensure accurate readings.
- Sample Preparation: Ensure your coffee sample is free of large grounds or particles that could interfere with the measurement.
- Temperature Stabilization: Allow hot or cold samples to stabilize in the measuring slot for at least 20 seconds to benefit from the automatic temperature compensation.
- Regular Zero-Setting: Perform a zero-setting with pure water regularly, especially if you notice inconsistent readings or after prolonged storage.
8. Warranty and Support
8.1. Service Voucher (Warranty Information)
The company provides a one-year warranty service for non-man-made damage from the date of purchase. This warranty covers manufacturing defects and normal operational failures.
The following conditions are NOT included in the warranty:
- Artificial damage or damage caused by improper use and custody.
- Failure or damage caused by dismantling and assembling without authorization of the company.
- Instruments purchased through informal channels.
8.2. General Warnings
- This instrument is a precise optical instrument. Prevent it from collision and fall.
- Forbid hard objects to scratch the optical prism in the measuring slot.
- When it is out of use, please store it in a place as dry as possible.
- USB charging voltage should not exceed DC6V limit.
8.3. Further Assistance
For a complete guide, detailed diagrams, and additional information, please refer to the official user manual PDF: