Aideepen STC-3008

Rate this product if you’ve used it
Contents

Aideepen STC-3008 Dual Digital Temperature Controller Instruction Manual

Model: STC-3008

1. Product Overview

The Aideepen STC-3008 is a microcomputer-controlled dual digital temperature controller designed for precise temperature management in various applications. It features dual LED displays for current and set temperatures, and supports both heating and cooling modes with two independent relay outputs. This device is suitable for household temperature control, farms, cold storage, greenhouses, aquariums, and more.

STC-3008 Microcomputer Temperature Controller with dual LED display and two temperature probes
Figure 1: STC-3008 Dual Digital Temperature Controller with probes.
Detailed description of STC-3008 components including precision components, sealed terminal block, anti-breakdown capacitor, clear display, and durable buttons.
Figure 2: Internal and external components of the STC-3008, highlighting precision, sealed terminals, and durable buttons.

2. Safety Information

  • Strictly distinguish the interface of the relay, sensor, and power supply.
  • Ensure proper connection of the sensor and power wires.
  • Keep sensor down-lead and power wires at a proper distance to avoid interference.
  • Always ensure the power supply matches the device's rated voltage (DC 12V/24V or AC 110-220V).

3. Installation and Wiring

3.1 Dimensions

STC-3008 dimensions: Front panel 75x34.5mm, Mounting 71x29mm, Product 75x34.5x85mm, Sensor length 1m.
Figure 3: Product and mounting dimensions.
  • Front panel size: 75(L) x 34.5(W) mm
  • Mounting size: 71(L) x 29(W) mm
  • Product size: 75(L) x 34.5(W) x 85(D) mm
  • Sensor length: 1 meter (including the probe)

3.2 Terminal Connections

STC-3008 terminal block diagram showing power supply, sensor inputs, and 10A/220VAC relay outputs.
Figure 4: Terminal block layout for power, sensors, and relay outputs.

The terminal block is designed for secure and reliable electrical connections. Ensure all wires are properly seated and tightened.

3.3 Wiring Diagram

The STC-3008 supports two main wiring configurations depending on whether the load requires an independent power supply or shares the same power supply as the controller.

Wiring diagram for STC-3008 showing two connection types: independent power supply for load and same power supply for load. Includes connections for power, sensor, and output.
Figure 5: Detailed wiring diagrams for independent and shared power supply configurations.

Connection 1: Independent Power Supply for Load

  • Connect the controller's power supply (N and L) to terminals 1 and 2.
  • Connect the temperature sensors to terminals 3-4 and 5-6.
  • Connect the independent power supply for the load to terminals 7 and 8 (L and N).
  • Connect the load (e.g., heater/cooler) to terminals 9 and 10 (Output).

Connection 2: Same Power Supply for Load

  • Connect the controller's power supply (N and L) to terminals 1 and 2.
  • Connect the temperature sensors to terminals 3-4 and 5-6.
  • Connect the load (e.g., heater/cooler) to terminals 9 and 10 (Output), sharing the same L and N lines as the controller.

4. Operating Instructions

4.1 Setting Start Temperature

  1. Press the "Up" button (△) once to display the current starting temperature.
  2. Long press the "Up" button (△) for approximately 3 seconds until the displayed temperature flashes.
  3. Use the "Up" (△) and "Down" (▽) buttons to adjust the desired starting temperature.
  4. The default starting temperature is 25°C.

4.2 Setting Stop Temperature

  1. Press the "Down" button (▽) once to display the current stop temperature.
  2. Long press the "Down" button (▽) for approximately 3 seconds until the displayed temperature flashes.
  3. Use the "Up" (△) and "Down" (▽) buttons to adjust the desired stop temperature.
  4. The default stop temperature is 40°C.

4.3 Parameter Settings (Advanced)

To enter the advanced setting mode, press both the "Up 1" (△) and "Up 2" (△) buttons simultaneously for 3 seconds. Use the "Up" (△) and "Down" (▽) buttons to navigate and adjust values. Wait for 2 seconds for the device to automatically exit the setting mode.

Table of parameter codes P0, P1, P2, P3 with functions, set ranges, and default values.
Figure 6: Advanced Parameter Settings Table.
Parameter Codes and Functions
Code Function Set Range Default
P0 Compressor 1 delay time 0-60min 0min
P1 Compressor 2 delay time 0-60min 0min
P2 High temperature alarm value -55 ~ 120°C 120°C
P3 Low temperature alarm value -55 ~ 120°C -55°C

4.4 Restore Factory Settings

To restore the device to its factory default settings, press the "Down 1" (▽) and "Down 2" (▽) buttons simultaneously.

5. Maintenance

  • Keep the device clean and free from dust and moisture.
  • Regularly check all wiring connections to ensure they are secure.
  • Avoid exposing the temperature probes to extreme physical stress or corrosive environments.
  • The cooling grid design aids in heat dissipation; ensure it is not obstructed for efficient cooling.
STC-3008 with text 'Effective Heat Dissipation' and 'Cooling grid design for more efficient cooling'.
Figure 7: Effective heat dissipation design.

6. Troubleshooting

This section provides solutions to common issues you might encounter with your STC-3008 temperature controller.

6.1 Common Issues

  • Incorrect Temperature Readings:
    • Check if the temperature sensors are properly connected and not damaged.
    • Ensure the sensor down-lead and power wires are kept at a proper distance to avoid electrical interference.
    • Consider performing a temperature correction if a known offset is present (refer to advanced settings if available, though not explicitly detailed for correction in provided data).
  • Controller Not Responding:
    • Verify the power supply is correctly connected and providing the specified voltage (DC 12V/24V or AC 110-220V).
    • Check for any loose wiring connections at the terminal block.
    • If the display is blank, ensure the power is on and connections are secure.
  • Load (Heater/Cooler) Not Activating:
    • Confirm that the set start and stop temperatures are appropriate for the desired operation (heating or cooling).
    • Check the relay output connections to the load.
    • Ensure the load itself is functional.
    • Verify the delay times (P0, P1) are not preventing immediate activation.

7. Specifications

Parameter Value
Model STC-3008 Dual Digital Temperature Controller
Temperature Sensor NTC 10K
Sensor Length 1 meter
Temperature Measuring Range -55 °C ~ 120 °C
Resolution 0.1 °C
Accuracy ±1 °C
Power Supply Options DC 12V, DC 24V, AC 110-220V
Power Consumption <3W
Storage Temperature -30 °C ~ 75 °C
Relative Humidity 20% ~ 85% (No condensate)
Relay Contact Capacity Cool 10A/240VAC; Heat 10A/240VAC
Front Panel Size 75(L) x 34.5(W) mm
Mounting Size 71(L) x 29(W) mm
Product Size 75(L) x 34.5(W) x 85(D) mm
Application Areas Household, Aquarium, Greenhouse, Aquaculture, Warehouse
Image of two dual temperature probes, highlighting their high quality and 1-meter length.
Figure 8: High-quality dual temperature probes.

8. User Tips

  • Power Loss Memory: The controller retains its programmed settings even after power loss or disconnection. This ensures your temperature parameters remain valid without needing to reconfigure after a power interruption.
  • Probe Placement: For accurate readings, ensure the temperature probes are placed correctly within the environment you wish to monitor and control, away from direct heat sources or drafts that could skew readings.
  • Voltage Selection: The STC-3008 comes in different voltage versions (DC 12V, DC 24V, AC 110-220V). Always ensure you have the correct version for your power supply to prevent damage.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. You may also refer to the official user manual PDF for additional details: