1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of the SUMRY ECO LV 3.6KW Hybrid Solar Inverter. This advanced inverter combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It is designed for both on-grid and off-grid applications, offering a pure sine wave output for sensitive electronics.
2. Key Features
- Pure sine wave solar inverter (on/off Grid capability)
- Output power factor 1.0
- WIFI & GPRS connectivity available for iOS and Android monitoring (optional module)
- Ability to run without a battery connected
- One-key restoration to factory settings
- Built-in Lithium battery automatic activation function
- AC output voltage 120VAC
- Built-in 120A MPPT Solar charge controller: max 4200W (for 3.6kW model)
- High PV input voltage range (60~500VDC)
- Built-in anti-dust kit for harsh environments
- Smart battery charge design to optimize battery life
- Dual output functionality
3. Specifications
General Product Specifications
| Attribute | Value |
|---|---|
| Brand Name | SUMRY |
| Model Number | ECO LV 3.6KW |
| Output Type | SINGLE |
| Output Current | 20A |
| Output Frequency | 50/60HZ |
| Continuous Power | 3.6KW |
| AC Output Voltage | 110VAC -50Hz/60Hz |
| Wave Form | Pure Sine Wave |
| Battery Voltage | 24VDC |
| Max Charge Current for Battery | 60A |
| Max Charge Current for Solar | 80A |
| Control Type | MPPT |
| Support Battery Type | Lithium battery, LiFePo4 |
| Communication Interface | RS232 |
| Size (L*W*H) | 50*41.5*18cm |
| Weight | 10KG |
| Certification | CE |
| Origin | Mainland China |
Detailed Technical Specifications
For detailed technical specifications, please refer to the Product Data Sheet image below. This sheet provides comprehensive information on PV input, grid/tie output, battery, and hybrid operation parameters.

4. Safety Information
Before installing or operating the inverter, please read and understand all safety instructions. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.
- Ensure all wiring is performed by qualified personnel.
- Do not attempt to open or repair the inverter yourself. Refer to qualified service personnel.
- Ensure proper grounding of the inverter.
- Keep the inverter away from flammable materials and ensure adequate ventilation.
- Verify correct polarity when connecting batteries and solar panels.
- Install appropriate circuit breakers as specified in the installation section.

5. Installation
Proper installation is crucial for the safe and efficient operation of your SUMRY ECO LV 3.6KW inverter. Follow these steps carefully.
5.1 Circuit Breaker Requirements
Before installing and using the inverter, it is recommended to install circuit breakers in the following four positions to prevent misconnection or reverse connection of the mains input and the inverter output, and to protect against short circuits, load short circuits, or overloads:
- Between the battery pack and the inverter battery input.
- Between the solar panel and the photovoltaic input of the inverter.
- Between the power input of the grid and the inverter.
- Between the inverter output and load.
For the SUMRY ECO LV 3.6KW (3600W) model, use the following circuit breaker specifications:
- Battery to Inverter: 2P100A circuit breaker
- Photovoltaic (PV) Input to Inverter: 2P20A circuit breaker
- Utility (AC) Input to Inverter: 2P50A circuit breaker
- Inverter Output to Load: 2P30A circuit breaker
5.2 Installation Steps
- Battery Connection: Install a 2P100A circuit breaker between the battery and the inverter. Keep the breaker open. Connect the 24V battery to the inverter's battery terminals. Close the circuit breaker and measure the voltage on the inverter's battery side to ensure it is correct.
- PV Input Connection: Install a 2P20A circuit breaker between the PV input and the inverter. Turn on this circuit breaker after successful installation. Ensure the battery voltage is normal. Connect the solar panels to the PV input. Close the circuit breaker between the PV input and the inverter. The inverter display should automatically light up and begin charging.
- Inverter Startup: Press the button on the bottom right corner of the inverter to start the machine. Verify that there is a 110V or 120V AC voltage output from the inverter's output terminals.
- AC Input & Output Connection: Install a 2P50A circuit breaker between the AC input and the inverter, and a 2P30A circuit breaker between the inverter's output and the load. After successful installation, turn on both the AC input and output circuit breakers. Connect the inverter to the mains utility. After 2 minutes, turn off the mains input circuit breaker, then turn off the circuit breaker of the inverter's output. This completes the installation procedure.


6. Operation
The inverter features an intuitive LCD display and function buttons for easy configuration and monitoring.
6.1 LCD Display and Function Keys

LED Indicator Messages:
| LED Indicator | Color | Messages |
|---|---|---|
| INV/AC | Green | Solid On: Output is powered by Utility in Line mode. Flashing: Output is powered by battery or PV in battery mode. |
| CHG | Green | Solid On: Battery is fully charged. Flashing: Battery is charging. |
| FAULT | Red | Solid On: Fault occurs in the inverter. Flashing: Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
6.2 Working Modes
The inverter offers versatile working modes to customize the priority of power inputs and outputs for efficient energy management.

Charging Modes:
- Solar First: Prioritizes solar power for charging batteries.
- Mains First: Prioritizes utility power for charging batteries.
- Hybrid Charge: Uses both solar and utility power for charging.
- Only Solar: Charges batteries exclusively from solar power.
Output Modes:
- Solar First: Prioritizes solar power for supplying loads.
- Mains First: Prioritizes utility power for supplying loads.
- Inverter First (SBU First): Prioritizes battery power (via inverter) for loads, then switches to utility if battery is low.
- Hybrid Output: Utilizes a combination of sources for load supply.
7. Communication
The SUMRY ECO LV series inverter supports various communication methods for monitoring and control.
7.1 WIFI & GPRS Communication (RS232)
The inverter features an RS232 communication port for connecting an optional WIFI module. This module enables remote monitoring via a mobile app (iOS and Android) as long as the inverter is connected to a network. It also allows for basic parameter settings. If you wish to use this feature, the WIFI module must be purchased separately.

7.2 Battery BMS Communication (RS485)
The inverter also includes an RS485 communication port specifically for lithium battery BMS (Battery Management System) communication. If you are using a lithium battery with BMS communication, ensure it supports either the PACE or PYLONTECH communication protocol for compatibility. A dedicated 485 communication cable is required and must be purchased separately, especially if the battery has a BMS protection board from PACE.

8. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter to prevent dust accumulation. The built-in anti-dust kit helps in harsh environments.
- Ventilation: Ensure the inverter's cooling fans are not obstructed. The intelligent cooling fan system adjusts speed based on temperature to maintain optimal operating conditions.
- Connections: Regularly check all electrical connections for tightness and signs of corrosion.
- Battery Health: Monitor battery voltage and performance, especially if using lead-acid batteries. The smart battery charge design helps optimize battery life.
- Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your inverter has the latest features and bug fixes.

9. Troubleshooting
If you encounter issues with your inverter, refer to the LED indicator messages in Section 6.1 for initial diagnosis. Common issues and their potential solutions are listed below:
- No Power Output: Check all circuit breakers (battery, PV, AC input, AC output) to ensure they are closed. Verify battery voltage and PV input voltage. Ensure the inverter is turned on.
- Battery Not Charging: Check PV input voltage and current. Ensure solar panels are clean and properly connected. Verify battery connections and health. Check charging mode settings.
- Inverter Fault/Warning: Refer to the LCD display for specific error codes or messages. Consult the full product manual (if available) or contact technical support with the error code.
- Overload Protection: Reduce the connected load. The inverter will automatically restart after an overload event. Ensure total load does not exceed 3600W continuous power.
- Overheating: Ensure adequate ventilation around the inverter. Clear any obstructions from the cooling fans.
10. User Tips
- Battery Compatibility: The inverter is compatible with various battery types including Lithium, LiFePo4, Gel, Lead-acid, and AGM. Ensure your battery type is correctly configured in the inverter settings for optimal charging and discharge cycles.
- Remote Monitoring: Consider purchasing the optional WIFI module for convenient remote monitoring and basic control via the Smartess App. This allows you to check system status from anywhere.
- System Sizing: When connecting appliances, be mindful of the inverter's continuous power rating (3600W) and peak power (7200W) to avoid overloading.
- Cable Sizing: Always use appropriately sized cables for all connections (PV, battery, AC input/output) to minimize power loss and ensure safety.
11. Warranty and Support
The SUMRY ECO LV 3.6KW Hybrid Solar Inverter comes with a 1-year warranty. For warranty claims, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Ensure you have your product model number and purchase date available when contacting support.