SUMRY ECO LV 3.6KW

Contents

SUMRY ECO LV 3.6KW Hybrid Solar Inverter User Manual

Model: ECO LV 3.6KW

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the SUMRY ECO LV 3.6KW Hybrid Solar Inverter. This advanced inverter combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It is designed for both on-grid and off-grid applications, offering a pure sine wave output for sensitive electronics.

2. Key Features

  • Pure sine wave solar inverter (on/off Grid capability)
  • Output power factor 1.0
  • WIFI & GPRS connectivity available for iOS and Android monitoring (optional module)
  • Ability to run without a battery connected
  • One-key restoration to factory settings
  • Built-in Lithium battery automatic activation function
  • AC output voltage 120VAC
  • Built-in 120A MPPT Solar charge controller: max 4200W (for 3.6kW model)
  • High PV input voltage range (60~500VDC)
  • Built-in anti-dust kit for harsh environments
  • Smart battery charge design to optimize battery life
  • Dual output functionality

3. Specifications

General Product Specifications

AttributeValue
Brand NameSUMRY
Model NumberECO LV 3.6KW
Output TypeSINGLE
Output Current20A
Output Frequency50/60HZ
Continuous Power3.6KW
AC Output Voltage110VAC -50Hz/60Hz
Wave FormPure Sine Wave
Battery Voltage24VDC
Max Charge Current for Battery60A
Max Charge Current for Solar80A
Control TypeMPPT
Support Battery TypeLithium battery, LiFePo4
Communication InterfaceRS232
Size (L*W*H)50*41.5*18cm
Weight10KG
CertificationCE
OriginMainland China

Detailed Technical Specifications

For detailed technical specifications, please refer to the Product Data Sheet image below. This sheet provides comprehensive information on PV input, grid/tie output, battery, and hybrid operation parameters.

Product Data Sheet for SUMRY ECO LV 3.6KW Inverter
Figure 3.1: Product Data Sheet for SUMRY ECO LV 3.6KW Inverter, detailing electrical and physical specifications.

4. Safety Information

Before installing or operating the inverter, please read and understand all safety instructions. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.

  • Ensure all wiring is performed by qualified personnel.
  • Do not attempt to open or repair the inverter yourself. Refer to qualified service personnel.
  • Ensure proper grounding of the inverter.
  • Keep the inverter away from flammable materials and ensure adequate ventilation.
  • Verify correct polarity when connecting batteries and solar panels.
  • Install appropriate circuit breakers as specified in the installation section.
Inverter with icons for various protections
Figure 4.1: The inverter features multi-functional safety protections including overload, short circuit, battery, overheating, overcurrent, and high/low voltage protection.

5. Installation

Proper installation is crucial for the safe and efficient operation of your SUMRY ECO LV 3.6KW inverter. Follow these steps carefully.

5.1 Circuit Breaker Requirements

Before installing and using the inverter, it is recommended to install circuit breakers in the following four positions to prevent misconnection or reverse connection of the mains input and the inverter output, and to protect against short circuits, load short circuits, or overloads:

  • Between the battery pack and the inverter battery input.
  • Between the solar panel and the photovoltaic input of the inverter.
  • Between the power input of the grid and the inverter.
  • Between the inverter output and load.

For the SUMRY ECO LV 3.6KW (3600W) model, use the following circuit breaker specifications:

  • Battery to Inverter: 2P100A circuit breaker
  • Photovoltaic (PV) Input to Inverter: 2P20A circuit breaker
  • Utility (AC) Input to Inverter: 2P50A circuit breaker
  • Inverter Output to Load: 2P30A circuit breaker

5.2 Installation Steps

  1. Battery Connection: Install a 2P100A circuit breaker between the battery and the inverter. Keep the breaker open. Connect the 24V battery to the inverter's battery terminals. Close the circuit breaker and measure the voltage on the inverter's battery side to ensure it is correct.
  2. PV Input Connection: Install a 2P20A circuit breaker between the PV input and the inverter. Turn on this circuit breaker after successful installation. Ensure the battery voltage is normal. Connect the solar panels to the PV input. Close the circuit breaker between the PV input and the inverter. The inverter display should automatically light up and begin charging.
  3. Inverter Startup: Press the button on the bottom right corner of the inverter to start the machine. Verify that there is a 110V or 120V AC voltage output from the inverter's output terminals.
  4. AC Input & Output Connection: Install a 2P50A circuit breaker between the AC input and the inverter, and a 2P30A circuit breaker between the inverter's output and the load. After successful installation, turn on both the AC input and output circuit breakers. Connect the inverter to the mains utility. After 2 minutes, turn off the mains input circuit breaker, then turn off the circuit breaker of the inverter's output. This completes the installation procedure.
Wiring diagram for SUMRY ECO LV 3.6KW inverter showing connections to solar, utility/generator, battery, and home appliances with circuit breakers.
Figure 5.1: Installation wiring diagram. Shows connections for solar power, utility/generator, external battery packs, and home appliances, with recommended circuit breaker placements.
Inverter powering various household appliances like a fridge, air conditioner, washing machine, and microwave oven.
Figure 5.2: The 3600W inverter can power common household appliances. Peak power is 7200W.

6. Operation

The inverter features an intuitive LCD display and function buttons for easy configuration and monitoring.

6.1 LCD Display and Function Keys

Inverter dimensions, LCD display, LED indicators, and function keys
Figure 6.1: Inverter dimensions (420*350*110mm), LCD display, LED indicators, and function keys.

LED Indicator Messages:

LED IndicatorColorMessages
INV/ACGreenSolid On: Output is powered by Utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHGGreenSolid On: Battery is fully charged.
Flashing: Battery is charging.
FAULTRedSolid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.

Function Keys:

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

6.2 Working Modes

The inverter offers versatile working modes to customize the priority of power inputs and outputs for efficient energy management.

Diagram showing 4 charging modes and 4 output modes for the inverter
Figure 6.2: Sectional Charging/Output source priority modes.

Charging Modes:

  • Solar First: Prioritizes solar power for charging batteries.
  • Mains First: Prioritizes utility power for charging batteries.
  • Hybrid Charge: Uses both solar and utility power for charging.
  • Only Solar: Charges batteries exclusively from solar power.

Output Modes:

  • Solar First: Prioritizes solar power for supplying loads.
  • Mains First: Prioritizes utility power for supplying loads.
  • Inverter First (SBU First): Prioritizes battery power (via inverter) for loads, then switches to utility if battery is low.
  • Hybrid Output: Utilizes a combination of sources for load supply.

7. Communication

The SUMRY ECO LV series inverter supports various communication methods for monitoring and control.

7.1 WIFI & GPRS Communication (RS232)

The inverter features an RS232 communication port for connecting an optional WIFI module. This module enables remote monitoring via a mobile app (iOS and Android) as long as the inverter is connected to a network. It also allows for basic parameter settings. If you wish to use this feature, the WIFI module must be purchased separately.

Inverter with optional WiFi/GPRS module for Smartess App monitoring
Figure 7.1: Monitor and control the inverter via the Smartess App using an optional WiFi/GPRS module connected to the RS232 port.

7.2 Battery BMS Communication (RS485)

The inverter also includes an RS485 communication port specifically for lithium battery BMS (Battery Management System) communication. If you are using a lithium battery with BMS communication, ensure it supports either the PACE or PYLONTECH communication protocol for compatibility. A dedicated 485 communication cable is required and must be purchased separately, especially if the battery has a BMS protection board from PACE.

Diagram showing RS485 communication line connection between inverter and battery BMS
Figure 7.2: The function and requirements of the 485 communication line for connecting to a lithium battery's BMS.

8. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Periodically clean the exterior of the inverter to prevent dust accumulation. The built-in anti-dust kit helps in harsh environments.
  • Ventilation: Ensure the inverter's cooling fans are not obstructed. The intelligent cooling fan system adjusts speed based on temperature to maintain optimal operating conditions.
  • Connections: Regularly check all electrical connections for tightness and signs of corrosion.
  • Battery Health: Monitor battery voltage and performance, especially if using lead-acid batteries. The smart battery charge design helps optimize battery life.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates to ensure your inverter has the latest features and bug fixes.
Diagram of intelligent cooling fans in the inverter
Figure 8.1: The inverter features intelligent cooling fans that adjust speed based on ambient temperature for efficient heat dissipation.

9. Troubleshooting

If you encounter issues with your inverter, refer to the LED indicator messages in Section 6.1 for initial diagnosis. Common issues and their potential solutions are listed below:

  • No Power Output: Check all circuit breakers (battery, PV, AC input, AC output) to ensure they are closed. Verify battery voltage and PV input voltage. Ensure the inverter is turned on.
  • Battery Not Charging: Check PV input voltage and current. Ensure solar panels are clean and properly connected. Verify battery connections and health. Check charging mode settings.
  • Inverter Fault/Warning: Refer to the LCD display for specific error codes or messages. Consult the full product manual (if available) or contact technical support with the error code.
  • Overload Protection: Reduce the connected load. The inverter will automatically restart after an overload event. Ensure total load does not exceed 3600W continuous power.
  • Overheating: Ensure adequate ventilation around the inverter. Clear any obstructions from the cooling fans.

10. User Tips

  • Battery Compatibility: The inverter is compatible with various battery types including Lithium, LiFePo4, Gel, Lead-acid, and AGM. Ensure your battery type is correctly configured in the inverter settings for optimal charging and discharge cycles.
  • Remote Monitoring: Consider purchasing the optional WIFI module for convenient remote monitoring and basic control via the Smartess App. This allows you to check system status from anywhere.
  • System Sizing: When connecting appliances, be mindful of the inverter's continuous power rating (3600W) and peak power (7200W) to avoid overloading.
  • Cable Sizing: Always use appropriately sized cables for all connections (PV, battery, AC input/output) to minimize power loss and ensure safety.

11. Warranty and Support

The SUMRY ECO LV 3.6KW Hybrid Solar Inverter comes with a 1-year warranty. For warranty claims, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Ensure you have your product model number and purchase date available when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.