1. Overview
This series of products is a single output DC regulated power supply with an LED digital display. It can simultaneously display voltage, current, power, and output time. Both voltage and current are continuously adjustable.
1.1 Functional Features
- LED digital display for voltage, current value, and selectable display of output time or output power.
- Stable voltage and stable current automatic switching.
- One-key output ON/OFF switch for flexible output control.
- Five powerful protection functions: Over-Voltage Protection (OVP), Over-Current Protection (OCP), Over-Power Protection, Over-Temperature Protection, and Short-Circuit Protection.
- 6 groups of quick parameter callback and storage function.
- Programmable sequence output with hardware List.
- Standard serial port supporting Modbus programming instruction set.
- Standard SENSE compensation interface.
- Adjustable output voltage and current, with simultaneous display of actual output values.
- Temperature-controlled fan for energy saving.
- One-key keyboard lock to prevent misoperation.
2. Safety Profile
This section contains important safety instructions that must be followed when operating and storing the power supply. To ensure your personal safety, please read this user manual carefully before operating to ensure the power supply is in the best working environment.
2.1 General Safety Guide
- Do not place heavy objects on the housing.
- Avoid damage to the machine due to serious impact or improper disposal.
- Take precautions against electrostatic discharge when connecting the instrument.
- Do not block or isolate fan vents.
2.2 Power Supply Safety
- Do not open the machine case unless you are a professional.
- AC input voltage: 220V ± 10%, 50Hz (or 110V input or 100V/220V manual switch). Ensure the correct voltage is selected if a manual switch is present.
- The ground cable of the power cable should be connected to the ground terminal to avoid electric shock.
- Make sure to use the correct fuse model before turning it on.
- To prevent fire, replace fuses that match the model and rating.
- Disconnect the power supply before replacing the fuse to rule out the cause of the damage.
2.3 Cleaning
- Disconnect the power before cleaning.
- Wet a soft cloth with mild detergent and clean water, and do not spray the cleaner directly.
- Do not use chemicals or cleaners that contain abrasive products such as benzene, toluene, xylene, and acetone.
2.4 Operating Environment
- Place of use: Indoors, away from direct sun, dust, and strong magnetic fields.
- Relative humidity: <80%
- Altitude: <2000m
- Temperature: 5°C to 40°C
2.5 Storage Environment
- Location: Indoors
- Relative humidity: <70%
- Temperature: 0°C to 70°C
3. Setup
3.1 Front and Rear Panels
Familiarize yourself with the controls and connections on the front and rear panels of the power supply.
Front Panel Controls:
- Output Voltage Display (V-out): Shows the actual output voltage. Pressing 'MENU' displays function menu names.
- Output Current Display (I-out): Shows the actual output current. Pressing 'MENU', 'OVP', or 'OCP' displays corresponding status values. 'ON/OFF' indicates the function's state.
- Time/Power/Status Display: In default mode, shows time in 'D-H-M-S' format (max 10 days). Power display shows actual output power in 'xxxxxxx.xxx' (Watts). Displays 'OFF' when output is off.
- Buzzer Function: A symbol lights up when the key sound is on, and is not displayed when off.
- Output ON/OFF Key: Directly controls power output. Green backlight indicates ON, red indicates OFF.
- M1-M6 Keys: Six groups of setting parameter storage keys. In normal mode, press to enter shortcut parameter preview/editing mode.
- 'List' Mode Key: Long press for 2 seconds to enter or exit the hardware List function mode.
- Current Adjustment Shuttle: Used to adjust the current value when the current is stable. Press down to move the current editing bit.
- 'B Lock' Key: Short press to return to the main interface. Long press for 2 seconds to lock/unlock the keyboard (all function keys except ON/OFF become invalid).
- 'I CC' Current Setting Key: Short press to enter the power current setting interface. The current data setting bit flashes. 'I CC' light on indicates steady current state.
- 'OVP' Overvoltage Setting Key: Short press to enter overvoltage function editing mode. The overvoltage threshold data setting bit flashes. Press again to switch the OVP function ON/OFF.
- 'U CV' Voltage Setting Key: In normal mode, press to enter the power voltage setting interface. The current data setting bit flickers. 'U CV' light on indicates current output at the voltage regulator state.
- 'OCP' Overcurrent Setting Key: Short press to enter overcurrent function editing mode. The overcurrent threshold data setting bit flashes. Press again to switch the OCP function ON/OFF.
- Voltage Regulation Shuttle: Used to adjust the voltage value when the voltage is stabilized. Press to move the current editing bit.
- 'Enter' Confirm Key: Enters the MENU function menu. Short press to save current options and data. In M1-M6 editing mode, saves current option data and switches to editing voltage, current, or time values.
- Arrow Keys: When in editing mode, left/right arrows move the cursor, up/down arrows increase/decrease the value by 1.
- 'MENU' Function Menu Key: Short press to enter or switch the function menu.
- Preset Current Display (I-set): Displays the preset current value in Amperes (A).
- Preset Voltage Display (V-set): Displays the preset voltage value in Volts (V).
Rear Panel Ports:
- SENSE Input Negative/Positive: Sampling points at the far end of the negative/positive output voltage of the power supply.
- Output Positive/Negative: Main power output terminals. Output current range: 0~maximum rating.
- Cooling Fan Vent: Used for power supply air cooling and heat dissipation.
- Fuse Holder: Equipped with a power fuse. Can be replaced by prying open with a flat-head screwdriver. Note: Models above 2400W (including) do not have a fuse holder, but a built-in circuit breaker.
- Power Input Socket: AC input port. For models above 2400W (including), a cable connects directly to the input AC power.
- Input Power Switch: AC110V/220V input switch (the default is not with this switch).
- Communication Interface: Standard RS485 communication serial port, supporting optional RS232/USB interface. Supports MODBUS communication protocol.
3.2 Connecting the Power Supply
- Input Power Requirements: Refer to the 'Specifications' section for detailed input power supply requirements.
- Check the Fuse: A suitable fuse has been installed when the instrument leaves the factory.
- Connect the Instrument Power Cord: Connect the instrument to the AC power supply using the power cord provided. For models above 2400W, connect the power cable directly to the AC power supply.
⚠️ To avoid electric shock, make sure the instrument is properly grounded.
4. Operation
4.1 Power-on Check
Press the power ON key. The backlight of the 'ON/OFF' key will show red, indicating the power output is in the OFF state. Press the 'ON/OFF' key again; the backlight will turn green, indicating the power output is ON.
Tip: If you turn on the power again after shutting it down, please ensure that the time interval between the two starts is longer than 5 seconds.
4.2 Output Check
The output check ensures that the instrument responds correctly to front panel operation and outputs the rated values. This includes checking voltage output when the channel is empty and current output when short-circuited.
Voltage Output Check:
- When the instrument is unloaded, turn on the power button to confirm that the current setting steady current value is not 0.
- Press the 'ON/OFF' key to open the output. When the backlight turns green, the channel is in the state of stable voltage output (C.V. Light up). Check that the voltage can be adjusted from 0 to the maximum rating.
Current Output Check:
- Turn on the power button.
- Adjust the voltage using the shuttle so that the power output voltage value is any value between 3-5V.
- Press 'ON/OFF' again to disconnect the output.
- Use a wire to short the front panel output terminal.
- Press the 'ON/OFF' key to turn on the output. After its backlight turns green, the channel is in a steady current output state (C.C. Light on). Check that the current can be adjusted from 0 to the maximum rating.
4.3 Stabilized Voltage Output (CV Mode)
The power supply provides two output modes: stabilized voltage output (CV) and stabilized current output (CC).
In CV mode, the output voltage is directly controlled by the voltage-regulated shuttle. For example, if the voltage is set to 16V, the current is set to its maximum rating (e.g., 5A for MY-305), and the load is 8Ω/300W, then 16V/8Ω = 2A. Since 2A is less than the maximum rating, the regulated voltage output will be 16V, with a 2A current supply.
Tip: In CV mode, if the output current exceeds the set value due to load changes, the instrument will automatically switch to CC mode according to the current set value, and the output voltage will also be reduced proportionally. At this point, the current setting value can be increased to restore the CV output.
Steps for CV Mode:
- Power On: Press the power button to start the instrument.
- Voltage Setting: Adjust the voltage regulating shuttle to set the desired voltage value (e.g., 16V).
- Current Setting: Adjust the current to its maximum rating using the shuttle.
- Connect Output Lead: Connect the output terminal of the instrument to the load as shown in the diagram below.
- Open Output: Press the 'ON/OFF' key (corresponding backlight green).
4.4 Steady Current Output (CC Mode)
In CC mode, the output current is controlled by the current regulating shuttle. For example, if the voltage is set to 16V, the current to its maximum rating (e.g., 5A for MY-305), and the load is 1Ω/300W, then 1Ω × 5A = 5V. Since 16V/1Ω = 16A, which is greater than 5A, this channel will output a steady current of 5A at 5V.
Tip: In CC mode, if the output voltage exceeds the set value due to load changes, the instrument will automatically switch to CV mode according to the current set voltage value, and the output current will also be reduced proportionally. At this point, the voltage setting can be increased to restore the CC output.
Steps for CC Mode:
- Power On: Press the power button to start the instrument.
- Voltage Setting: Adjust the voltage regulating shuttle to set the desired voltage value (e.g., 16V).
- Current Setting: Adjust the current to the maximum rating using the shuttle.
- Connect Output Lead: Connect the output terminal of the instrument to the load.
- Open Output: Press the 'ON/OFF' key (corresponding backlight green). The instrument will work in the steady current output mode.
⚠️ An incorrect connection can result in damage to the product or the device connected to it.
4.5 Video Demonstration: OVP/OCP Settings
Watch this video for a demonstration of OVP (Over-Voltage Protection) and OCP (Over-Current Protection) settings and their automatic disconnection functions.
5. Maintenance
5.1 Regular Inspections
During the use of the product, to ensure it operates in its best working condition, please perform regular inspections:
- Check that the power supply input socket is not burnt out.
- Check for any loose power output terminals.
5.2 Replacement of Fuses
Steps:
- Remove the power cord.
- Use a small screwdriver to remove the fuse box.
- Replace the fuse with one of the correct specifications.
Fuse Specifications:
- Models with power ≤ 1200W:
- 220V: F10A/250V
- 110V: F20A/250V
- Models with power between 1200W and 2400W:
- 220V: F20A/250V
Note: Models with power ≥ 2400W do not come with this fuse, as they feature a built-in circuit breaker.
6. Troubleshooting
- No Output: Ensure the 'ON/OFF' button is pressed and its backlight is green. Check the power cord connection and the fuse (if applicable).
- Output Disconnects Unexpectedly: Check OVP (Over-Voltage Protection) and OCP (Over-Current Protection) settings. If triggered, adjust the voltage/current limits to appropriate values for your load.
- Incorrect Voltage/Current Reading: Verify that the SENSE connections (if used) are correct and secure. Ensure the output terminals are properly connected to the load.
- Unit Not Powering On: Check the power input cable and the main power switch. If applicable, inspect the fuse for damage and replace if necessary.
- Fan Not Running: The fan is temperature-controlled. It may not run if the internal temperature is low. If the unit is hot and the fan is still not running, ensure fan vents are not blocked.
7. Specifications
7.1 Display Resolution
| Parameter | Range | Resolution |
|---|---|---|
| Voltage | < 100V | 10mV |
| ≥ 100V | 100mV | |
| Current | < 100A | 10mA |
| ≥ 100A | 100mA | |
| Power | < 10W | 1mW |
| ≥ 10W | 10mW | |
| ≥ 100W | 0.1W | |
| ≥ 1000W | 1W | |
| Time | N/A | Seconds (S) |
7.2 Output Parameters
(When using this specification, ensure the unit is turned on for more than 10 seconds)
- Voltage stability: ≤0.2%
- Current stability: ≤0.5%
- Load stability: ≤0.5%
- Ripple and noise: ≤1% (effective value)
7.3 Preset Accuracy
- Output voltage: ± 0.1V
- Output steady current: ± 0.1A
7.4 Operating Environment
- Use: Indoor
- Altitude: ≤2000m
- Ambient temperature: 5°C ~ 40°C
- Relative humidity: <80%
7.5 Storage Environment
- Storage: Indoor
- Ambient temperature: 0-70°C
- Relative humidity: <70%
7.6 Power Input
AC220V ± 10%, 50Hz (or AC110V input or AC100V/220V manual switch)
7.7 Accessories
- 1 x Instruction Manual
- 1 x Certificate of Qualification
- 1 x Power Cord (for models below 2400W)
7.8 Physical Dimensions
- Bare Device Size:
- < 2400W model: 330(D) × 250(W) × 155(H) mm
- ≥ 2400W models: 410(D) × 250(W) × 155(H) mm
- Package Size:
- < 2400W models: 420(D) × 310(W) × 220(H) mm
- ≥ 2400W models: 497(D) × 310(W) × 220(H) mm
7.9 Communication Parameters
- Baud rate: 9600
- Starting bit: 1
- Data bit: 8
- Check bit: None
- Stop bit: 1
7.10 Weight
| Type | <2400W | ≥2400W |
|---|---|---|
| Net weight | About 5Kg | About 7.5Kg |
8. Product Declaration of Toxic and Harmful Substances
| Components Name | Pb | Hg | Cd | Cr(VI) | PBB | PBDE |
|---|---|---|---|---|---|---|
| Printed circuit components | X | O | O | O | O | O |
| Transformer | X | O | O | O | O | O |
| Connecting wire | X | O | O | O | O | O |
| Hardware case | X | O | O | O | O | O |
| Power cord | X | O | O | O | O | O |
| Electronics Materials | O | O | O | O | O | O |
| Plastic Panels | O | O | O | O | O | O |
| Packaging Materials | O | O | O | O | O | O |
O: Indicates that the content of the toxic and hazardous substance in all homogeneous materials of the part is below the limit requirements specified in the SJ/T11363-2006 standard.
X: Indicates that the content of the toxic or harmful substance in at least one homogeneous material of the component exceeds the limit requirements specified in the SJ/T11363-2006 standard.
Note: This table shows that the product may contain these substances, but this information may be updated with the development of technology. The reason for the 'X' is that there is no alternative technology or component available at the present stage, and it complies with the regulations of the People's Republic of China "Measures for the Control and Administration of Pollution from Electronic Information Products".
9. Warranty and Support
9.1 Warranty Service
Sincerely thank you for choosing this power supply. Our company will strictly implement the national three-guarantee policy. For quality problems of the product itself not caused by human factors, you can handle repair, replacement, and return by presenting the invoice and the certificate of three guarantees.
- Please pack and ship the products properly when you send them for repair. If any damage or loss occurs during delivery, the company will not be responsible for it.
- Please make sure that the warranty card is stamped and dated by the after-sales unit to ensure your rights and interests.
- The following circumstances are not exempt from the service scope:
- More than the validity period of three packages.
- Altering the certificates of the three packages without authorization.
- Failure to use, maintain, and keep the product according to the instructions for use, resulting in damage.
- Product damage caused by natural disaster, power grid failure, or other irresistible factors.
- Accessories are not covered by warranty.
- The product model or number on the certificate of three packages is inconsistent with the real product.
A user manual in PDF format is available for download: MYAMi MY-K15005PE User Manual (PDF)
10. User Tips
- Always double-check your wiring connections before applying power to avoid damage to your circuit or the power supply.
- When starting a new project, begin with lower voltage and current settings and gradually increase them to the desired levels while monitoring your circuit.
- Utilize the M1-M6 memory presets for frequently used voltage and current configurations to save time and ensure repeatable results.
- Ensure adequate ventilation around the power supply, especially during prolonged operation at high loads, to prevent overheating.
- Regularly inspect the output terminals for any signs of wear or looseness to maintain good electrical contact.