1. Product Overview
The PUSR USR-TCP232-410S-H7 is an industrial-grade serial to Ethernet converter designed to provide reliable serial to Ethernet connectivity. It supports bi-directional transmission between RS232/RS485 and Ethernet, allowing any serial device to connect to an Ethernet network. This device features edge computing capabilities, MQTT/SSL encryption, and functions as a Modbus RTU to Modbus TCP gateway.

Key Features
- Dual Serial Ports: RS485 + RS232, can work simultaneously.
- Edge Computing: Modbus TCP/RTU protocol conversion with up to 128 points for addition/subtraction/multiplication/division.
- SSL Encryption: Supports TCPC+SSL, HTTPS, MQTTS to ensure data communication security, user authentication, data integrity, and confidentiality.
- User-defined Webpage: User can customize the webpage for configuration.
- Industrial Design: Operates in temperatures from -40°C to +85°C, with 5-36V DC power input.
- Rich Protocols: Supports TCP, UDP, MQTT, HTTP.
- MQTT: Can connect to IoT platforms with standard MQTT.
- Modbus Gateway: Modbus TCP/RTU protocol conversion, multi-host polling (up to 16 hosts).
- Ethernet Interface: 10/100Mbps with Auto-MDI/MDIX.
- Flow Control: Supports RTS/CTS hardware flow control and Xon/Xoff software flow control.
- Baud Rate: 600bps~230.4Kbps, with various parity options.

2. Setup Guide
2.1. Package Contents
Before you begin, please verify that all items are present in the package:
- 1 x USR-TCP232-410S-H7 Serial Device Server
- 1 x Female-to-Female Serial Cable
- 1 x Power Adapter

2.2. Hardware Installation
The USR-TCP232-410S-H7 features an industrial design for robust installations. It can be mounted using its integrated mounting brackets.
2.2.1. Device Dimensions
The device has the following approximate dimensions:
- Length: 90 mm
- Width: 68 mm
- Height: 24 mm (excluding connectors)
2.2.2. Port Description
The device includes:
- Power Input: DC 5-36V via terminal block.
- Ethernet Port: RJ45 for 10/100Mbps network connection.
- RS232 Port: DB9 male connector.
- RS485 Port: 3-pin terminal block (A(+), B(-), G).
- Reload Button: For resetting to default settings.
2.2.3. LED Indicators
The device features several LED indicators to show its status:
| LED | Status |
|---|---|
| POWER | Light On: Power is supplied. Light Off: No power. |
| WORK | Blinking: Working normally. Off or Light On (Solid): Not working normally. |
| 232TX | Blinking: Sending data via RS232. Off: No data being sent via RS232. |
| 232RX | Blinking: Receiving data via RS232. Off: No data being received via RS232. |
| 485TX | Blinking: Sending data via RS485. Off: No data being sent via RS485. |
| 485RX | Blinking: Receiving data via RS485. Off: No data being received via RS485. |
2.3. Initial Configuration
The device can be configured using setup software, a web server, or AT commands.
2.3.1. Using Setup Software
- Download the setup software from the official USR IOT website (e.g.,
https://www.usriot.com/support/downloads/usr-tcp232-m4k3-setup-software.html). - Connect your PC to the same LAN as the USR-TCP232-410S-H7.
- Run the setup software and click 'Search Device' to find the converter on the network.
- Select the device from the list and click to configure. You may need to log in with the default username and password (both are 'admin').
- Configure network parameters (Static IP/DHCP), serial port parameters, and work mode as required.
2.3.2. Using Web Server
- Connect your PC directly to the device's Ethernet port or ensure they are on the same network.
- Open a web browser and enter the default IP address:
192.168.0.7. - Log in using the default username and password (both are 'admin').
- The web interface allows you to configure all device parameters.
2.3.3. Reset to Default Settings
Hardware Reset: Power off the device. Press and hold the 'Reload' button, then power on the device. Keep holding the 'Reload' button for more than 5 seconds to reset to factory defaults.
Software Reset: Use the setup software or send the AT command AT+RELD to reset the device.
3. Operating Instructions
3.1. Network Modes
The USR-TCP232-410S-H7 supports various network operation modes:
- TCP Client: Connects to a specified TCP server to transmit data. Supports Keep-Alive function and baud rate synchronization.
- TCP Server: Listens for incoming TCP client connections. Supports up to 8 client connections and baud rate synchronization.
- UDP Client: Sends data to a specified remote IP/Port. Unreliable but simple communication.
- UDP Server: Receives UDP data and sends responses to the latest communication IP/Port.
- HTTP Client: Allows the device to send data to an HTTP server.
- WebSocket: Enables real-time interaction between the serial interface and a web server.
3.2. Serial Port Configuration
The serial ports (RS232 and RS485) can be configured independently with the following parameters:
| Parameter | Range |
|---|---|
| Baud Rate | 600 ~ 230.4Kbps |
| Data Bits | 5, 6, 7, 8 |
| Stop Bits | 1, 2 |
| Parity Bits | None, Odd, Even, Mark, Space |
3.2.1. Flow Control
The device supports hardware flow control (RTS/CTS, effective for RS232 only) and software flow control (Xon/Xoff).
3.2.2. Serial Package Methods
Serial data is buffered and sent as data packages over the network. Packages can be ended by:
- Time Trigger Mode: Data is sent after a specified time interval (0-255ms).
- Length Trigger Mode: Data is sent after a specified length is reached (0-1460 bytes).
3.3. Advanced Features
3.3.1. Edge Computing
The device can perform basic arithmetic operations (addition, subtraction, multiplication, division) on data points, supporting up to 128 points. This allows for local data processing before transmission to the cloud.

3.3.2. Modbus Gateway
The device acts as a Modbus gateway, supporting Modbus RTU/ASCII transparent transmission and Modbus RTU to Modbus TCP protocol conversion. It also supports Modbus polling for up to 16 hosts.
3.3.3. Data Transmission Encryption
For secure communication, the device supports SSL encryption including TCPC+SSL, HTTPS, and MQTTS, ensuring user authentication, data integrity, and confidentiality.

3.3.4. Identity and Heartbeat Packets
- Identity Packet: Used to identify the device when operating as a TCP/UDP client. Can be MAC address or user-defined.
- Heartbeat Packet: Periodically sent to the serial or network side to maintain connections and poll Modbus data.
3.3.5. VCOM Application
The device supports virtual COM port (VCOM) software, allowing traditional PC software designed for serial communication to interact with the device over Ethernet.
3.3.6. Network Printing
The device can function as a printer server, enabling network printing for serial printers.
3.3.7. Editable Web Server
The device's web server interface can be customized based on templates, allowing users to tailor the configuration interface to their specific needs.
4. Maintenance
To ensure the longevity and optimal performance of your PUSR USR-TCP232-410S-H7, follow these maintenance guidelines:
- Power Supply: Always use the provided power adapter or a compatible DC 5-36V power supply. Ensure stable power to prevent damage.
- Environment: Operate the device within its specified temperature range (-40°C to +85°C) and avoid environments with excessive dust, moisture, or corrosive gases.
- Cleaning: Keep the device clean. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or solvents.
- Firmware Updates: Periodically check the official USR IOT website for firmware updates to ensure you have the latest features and security patches.
5. Troubleshooting
5.1. No Power / Device Not Starting
- Check Power Connection: Ensure the power adapter is securely connected to the device and a working power outlet.
- Verify Power Supply: Confirm the power supply voltage is within the 5-36V DC range.
- Check Power LED: If the POWER LED is off, there is no power reaching the device.
5.2. Network Connectivity Issues
- Ethernet Cable: Ensure the Ethernet cable is securely connected to both the device and the network switch/router.
- Network Configuration: Verify that the device's IP address, subnet mask, and gateway are correctly configured and match your network settings. If using DHCP, ensure a DHCP server is available.
- Ping Test: From a computer on the same network, try to ping the device's IP address. If unsuccessful, check network settings and physical connections.
5.3. Serial Data Transmission Problems
- Serial Port Parameters: Ensure the baud rate, data bits, stop bits, and parity settings on the device match those of the connected serial device.
- Wiring: Double-check the RS232/RS485 wiring for correct pin connections (Tx/Rx, A/B).
- Serial LEDs: Observe the 232TX/RX and 485TX/RX LEDs. They should blink when data is being transmitted or received.
- Work Mode: Verify that the device's work mode (e.g., TCP Client, TCP Server) is correctly configured for your application.
5.4. Device Unresponsive / Cannot Access Web Interface
- IP Address: Confirm you are using the correct IP address for the device.
- Reset to Defaults: If configuration issues persist, perform a hardware reset to factory default settings and reconfigure.
6. Specifications
| Attribute | Value |
|---|---|
| Brand Name | PUSR |
| Processor | ST Solution, Cortex-M7 |
| Frequency | 400MHz |
| Interface Type | RS-232, RS-485, RJ45 Ethernet |
| Port Number | 1 x RJ45 (10/100 Mbps, auto MDI/MDX, 1.5KV isolation), 1 x RS232 (DB9-male), 1 x RS485 (3-pin terminal block) |
| LAN Ports | 0 (Single RJ45 for network connection) |
| Max. LAN Data Rate | 100Mbps |
| Wi-Fi Transmission Standard | 802.11b (Note: This device is primarily wired Ethernet, Wi-Fi standard might refer to internal component spec or general capability, but primary interface is Ethernet) |
| Baud Rate | 600 bps ~ 230.4Kbps |
| Network Protocol | IP, TCP, UDP, HTTP, MQTT, SSL/TLS, ARP, ICMP, DHCP, DNS |
| Config Method | Built-in Webpage, ConfigSoftware, AT Command |
| Work Mode | TCP Server/TCP client/UDP Server/UDP Client/HTTPD client |
| Edge Computing | YES, up to 128 points |
| Encryption | MQTT+SSL, TCPC+SSL |
| Modbus Gateway | Modbus RTU/TCP protocol conversion, Multi-host polling: up to 16 hosts |
| Certification | CE, FCC |
| Origin | Mainland China |
| High-concerned chemical | None |
7. Warranty and Support
7.1. Technical Support
For technical assistance, documentation, and software downloads, please visit the official USR IOT support website:
- Technical Support:
h.usriot.com
You can also contact USR IOT directly:
- Company: Jinan USR IOT Technology Limited
- Address: Floor 11, Building 1, No. 1166 Xinluo Street, Gaoxin District, Jinan, Shandong, 250101, China
- Website:
www.usriot.com - Email:
sales@usr.cn - Tel: +86-531-88826739 / +86-531-55507297
A detailed user manual in PDF format is also available for download from the seller's product page or the manufacturer's website.
8. User Tips
- Initial Setup: For first-time setup, it's often easiest to connect the device directly to a PC via Ethernet and use the default IP (192.168.0.7) to access the web interface or setup software.
- Modbus Polling: When using the Modbus gateway feature, ensure your Modbus RTU devices have unique addresses and that the polling interval is appropriate for your application to avoid network congestion.
- Security: If connecting to public networks or cloud services, always enable SSL/TLS encryption (MQTT+SSL, TCPC+SSL) for data security.
- Firmware: Keep the device's firmware updated to benefit from the latest features, improvements, and security enhancements.