1. Introduction and Safety Precautions
The Heltec Lithium Battery Maintenance Equalizer & Analyzer utilizes advanced MCU chips for precise real-time detection and analysis of lithium battery packs. It supports up to 32 strings and offers high accuracy, strong timeliness, simple operation, and practical reliability.
General Safety Warnings:
- Operation is strictly prohibited for non-technical personnel. Ensure you understand the machine's functions before use.
- When connecting the equalizer to the battery module, pay close attention to the polarity and sequence of the battery pack to match the output terminal requirements. Incorrect connection can damage the equalizer and cause internal discharge components to burn.
- The equalizer must be placed in a well-ventilated environment during operation due to significant heat generation. Do not insert foreign objects or metal objects into the heat dissipation area to prevent explosion.
- Pay attention to the polarity and voltage of the charging power output. Connecting the wrong charging polarity can damage the instrument and potentially the charger.
- Personnel must monitor the instrument and battery module when equalizing. Do not leave unattended.
- Use only the battery pack connection line randomly matched with the equalizer. Modifying the connection line is prohibited and may lead to accidents.
- The equalizer contains high-voltage circuits and components. Do not disassemble or modify the unit.
- Protect the instrument from water or mist to prevent damage to electrical components.
2. Key Features
- Automatic Voltage Analysis: Automatically collects and analyzes the voltage of each battery string, monitoring changes during equalization.
- Intelligent Control: Main control chip (MCU) intelligently analyzes, controls charging/discharging, and initiates equalization.
- Remote Control: Bluetooth connectivity for remote control via a mobile app (Android only, app updates continuously).
- Efficient Heat Dissipation: Reasonable internal component layout with a cooling system to prevent high-temperature impact on electronics.
- Wide Compatibility: Supports 2-32S battery modules for Li-ion/LiFePO4/LTO batteries.
- Adjustable Equalization Current: Maximum 25A, allowing precise equalization for various battery types.
- Integrated Charging System: Built-in charging system for combined charging and discharging control.
- Safe Charging Regulation: Matches charging voltage to battery type and string count for safer operation.
- Discharge Equalization Modes: Offers continuous discharge and pulse discharge modes based on battery pack aging and equalization needs.
- Humanized Operation Panel: Movable panel for adjustable viewing angles.
- 5-inch Color LCD Touch Screen: Microcomputer control with a large LCD for clear display of parameters.
- High Current Discharge Function: Supports max. 25A high-speed discharge.
- Battery Internal Resistance Calculation: Determines DC internal resistance via continuous current discharge.
- Intelligent Safety System: High security against reverse control, wrong connections, and accidental battery risks.
- Highly Redundant 50A Connector: Professional-grade 24K gold-plated connectors ensure high current equalization without overheating.
Key advantages of the Heltec Equalizer, including precision detection and intelligent control.
3. Specifications
| Attribute | Value |
|---|---|
| Product Name | New energy vehicle lithium battery module equalization repair analyzer |
| Product Model | HTB-J24S10AC / HTB-J24S15AC / HT-CJ32S25A |
| Voltage | AC110V~220V |
| Application | Li-ion/LifePO4/LTO |
| Battery Pack Strings | 2-24 strings (HTB-J24S models), 2-32 strings (HT-CJ32S25A) |
| Minimum Balanced Voltage | 1mv |
| Start Charge Equalization Strings / Voltage | More than 10 strings / 30V |
| Maximum Balanced Current | 10A / 15A / 25A (Optional) |
| Charging Connection | XT-60 |
| Equalization Mode | Pulse discharge equalization, continuous discharge equalization |
| Equilibrium Pressure Difference Accuracy | ±0.001V |
| Product Dimensions (LxWxH) | 275x242x140mm |
| Package Size (LxWxH) | 330x305x230mm |
| Package Weight | 3.34kg |
Detailed specifications for the HTB-J24S15AC model.
Physical dimensions of the equalizer unit.
4. Package Contents
The package typically includes:
- Heltec Lithium Battery Maintenance Equalizer and Analyzer Unit
- Power Cord
- Balance Connection Cable (with clips)
- Battery Connector (XT-60)
- Line Sequence Test Board
- Instructions (User Manual)
- Touchscreen Pen
- 32-channel output/input terminal (33 wires)
- Extension Cord Clip (33 wires)
Visual representation of the items included in the HT-CJ32S25A package.
Visual representation of the items included in the HTB-J24S15AC package.
5. Setup Instructions
5.1. Battery Pack Connection
- Connect the cables to the battery pack in order. Ensure the black wire corresponds to the total negative pole of the battery pack.
- After connecting the cables, use the provided wire sequence test board to verify the correct wire sequence. When connected correctly, the indicator lights on the test board will light up green according to the number of battery strings.
- Once the connection is correct and verified, connect the cable to the equalizer. The black line must correspond to the B0 position on the equalizer.
Video demonstrating the battery pack cable connection and line sequence test.
Wiring diagram for both charge and discharge equalization modes for HTB-J24S15AC.
Details of the universal adapter board, applicable for 3-24 strings.
5.2. Power Connection
- Connect the power cord to the equalizer and a suitable AC power outlet.
- Turn on the main power switch located at the back of the machine.
- Press the power button on the front panel and drag the scroll bar to adjust the screen brightness.
Rear view of the equalizer, indicating the AC power supply and main switch.
6. Operation
6.1. Initial Setup and Language Switching
- After powering on, click 'OK' to enter the home page.
- To switch the language, click 'Parameter settings', then enter "28972123" in the equalization pressure difference column.
6.2. Parameter Settings
- Press the "Start" button to initiate the battery pack monitoring system.
- Enter the parameter setting page. Select the battery pack type (Li-ion, LiFePO4, or LTO).
- Set the number of battery strings connected to the battery pack.
- Click 'Save settings'.
The 5-inch touch screen interface for main parameters and settings.
Intelligent display showing charging parameters and battery string settings.
6.3. Discharge Equalization Mode
- Pulse Discharge Mode: After obtaining the lowest voltage, enter the parameter setting page. Set the equalization limit to the lowest voltage (e.g., 3.6V for the battery pack in the video). After settings are complete, click 'Save settings' to start discharge equalization. The equalization indicator light will flash, indicating the system is in equalization state.
- Continuous Equalization Mode: Press "STOP" to pause pulse equalization, then press the "A-MAX" continuous equalization button. The equalization indicator light will remain on. This mode is suitable for fast and efficient equalization. For high-precision balancing, use pulse discharge mode.
- You can enter the "Status Display" page to monitor the real-time voltage changes of each battery string. Blue represents the lowest battery voltage, and red represents the highest.
Diagram illustrating the discharge balance process before and after equilibrium.
Discharge balance settings, allowing flexible adjustment of start equalizing voltage and voltage difference.
6.4. Charging Equalization Mode
- Connect the XT-60 cable with clips to the battery pack input port. The black clip line must be connected to the total negative pole, and the red clip line to the total positive pole.
- Connect another XT-60 cable to the charger output port.
- Turn on the charger and press its power button.
- Adjust the charging voltage and set it to the highest voltage of the entire battery pack (e.g., for a Li-ion battery pack, 12 * 4.2V = 50.4V).
- After adjusting the voltage, connect the XT-60 red wire to the positive pole of the power supply.
- Press the "Charge On" button on the equalizer and adjust the current knob to the minimum. Then adjust the current size according to demand.
- After successful charging connection, the screen displays a connection success icon.
- Click to enter the status display page to monitor the real-time voltage changes of each battery string.
- Set the "Equalization Limit" and "Equalization Start" to the same voltage and save the settings. When the voltage reaches the equalization control voltage, the battery pack will be automatically discharged to the set voltage.
Please note: In the charging and equalization state, you need to manually stop charging and equalization after completing the process.
Diagram illustrating the charge balance process before and after equilibrium.
Charge balance settings, allowing flexible adjustment of start equalizing voltage and voltage difference.
6.5. Mobile App Connection and Control
Note: Currently, the network remote monitoring APP only supports Android users. Apple users need to use the Bluetooth function to achieve mobile phone control. The APP is being continuously updated. Please contact customer service for support.
- On the "Network Settings" page, click "Network Connection WIFI/Hotspot".
- If the network connection is successful, the Wi-Fi icon will be displayed in the upper right corner.
- Open the APP and click the device list in the upper right corner.
- Click "Scan" to register and aim your phone camera at the QR code on the "Network Settings" page of the machine.
- When connecting, you need to enter the password displayed on the machine. (To ensure safety, do not disclose the password. The password can be modified on the machine).
- After successful connection, you can remotely view the real-time status of the battery pack and control the equalizer via your mobile phone.
7. Maintenance
- Keep the equalizer clean and free from dust.
- Ensure the instrument is not exposed to water or mist, as this can cause damage to internal components.
- Always use the original battery pack connection lines provided with the equalizer. Do not modify or add to these lines.
- Avoid disassembling or attempting to modify the equalizer, as it contains high-voltage circuits.
- Store the manual properly for future reference.
The double fan system ensures strong heat dissipation, improving wind speed and reducing heat.
8. Troubleshooting
Common Error Codes:
| Error Code | Clarification |
|---|---|
| E01 | Charging cable reversed or not connected to the battery. |
| E02 | Charging voltage exceeds the set voltage. |
| E03 | Charging current exceeds set current. |
| E04 | Charge current less than 1/6 of set current. |
| E05 | Charging time has reached the maximum time. |
| E06 | No current output. |
| E07 | No voltage output. |
| E08 | Setting voltage lower than battery voltage. |
General Issues and Limitations:
- The equalizer cannot repair damaged battery packs with: increased internal resistance, voltage lower than discharge termination, short/open circuits, or damaged BMS.
- If the instrument is set to MAX. function mode for real-time current measurement, it operates in a continuous current state. Otherwise, equalizers without MAX. function use pulse current, and ordinary current measuring instruments may not measure the actual current value accurately.
- Battery end voltage may rise after energy consumption discharge. This is normal and does not indicate poor equalization. Fine balancing over time is recommended.
9. User Tips
- Balancing Speed vs. Accuracy: The equalization effect is related to both time and speed. Faster equalization may result in worse accuracy. For optimal balance accuracy, it is suggested to set a smaller balance current value.
- Continuous Current Mode: The equalizing current marked on the equalizer refers to the discharge current when the battery has the highest voltage (e.g., 4.2V for ternary lithium battery). The instrument is designed for constant resistance discharge. The equalizing current decreases as battery voltage drops or for low voltage units, which is a normal phenomenon.
10. Warranty and Support
The manufacturer, Heltec Energy, reserves the right to upgrade the machine and modify the manual without prior notice. Any damage resulting from unauthorized disassembly or improper human operation will not be included in the warranty.
For detailed information or any questions, please contact customer service:
- Website: https://www.heltec-energy.com/
- E-mail: echo@heltec-bms.com
- Tel: 18123313360
- Address: 64th ChengHong road, Chenghua Section, Chengdu, SiChuan, China