1. Getting Started & Setup
Important Note: Power up the pool sensor first and then the Display Console. Do not press any buttons until all data has been received.
1.1 Parts List
The package includes the following components:
- 1 x Display Console: Size: 4.76"x2.9"x0.59" (12.1x7.5x1.5cm), LCD Size: 2.99"x1.77" (7.6x4.5cm)
- 1 x Pool Transmitter (Sensor): Size: 6.9"x4.2"x3.7" (17.5x10.6x9.5 cm)
- 1 x User Manual
- 2 x Wrenches: One for the upper lid and one for the lower lid of the pool sensor.

Image: Pool thermometer, display console, 2 wrenches, and user manual.
1.2 Battery Installation - Pool Sensor (Transmitter)
Note: To avoid permanent damage, observe battery polarity carefully. For temperatures below -4°F (-20°C), fresh lithium batteries are recommended.
- Unlock: Twist the KEY to unlock the sensor.
- Remove Key: Remove the KEY from its slot.
- Open Sensor: Use the included wrenches to twist and separate the main body of the sensor by removing both the upper and lower lids.
- Install Batteries: Insert 4 x AAA batteries, paying close attention to the correct polarity.
- Desiccant Pack: Place the desiccant pack (from its plastic bag) into the main body of the sensor to absorb moisture.
- Check Gaskets: Before closing, ensure both red colored gaskets are properly seated in their tracks to maintain waterproofing. Failure to properly seal will result in water leakage and damage.
- Close Lid: Twist the upper and lower lids with the wrench until firmly locked and the key hole is aligned.
- Lock Lid: Insert the key and turn it 90 degrees to fully lock the lid.
- Tether (Optional): A tether (not included) can be attached to the key hole to secure the sensor.
1.3 Wrench Usage Instructions
The wrenches are designed for easy opening and closing of the pool sensor. Ensure the wrench is faced up with the word “UP” facing upwards.
- Small Wrench: Attach the small wrench tightly to the lower cover of the sensor.
- Big Wrench: Attach the big wrench to the upper cover, ensuring it matches tightly, especially aligning with the arrow positioning.
- Position Wrenches: Make sure the two wrenches are matched at a 90-degree angle for optimal leverage.
- Open Sensor: Hold the big wrench with your left hand and turn the lid counter-clockwise while firmly holding the small wrench with your right hand. Use your right thumb to prevent the big wrench from slipping.
1.4 Battery Installation - Display Console
- Remove Door: Remove the battery door on the back of the console.
- Insert Batteries: Insert 2 x AAA batteries (alkaline or lithium; avoid rechargeable).
- Close Door: Close the battery door. The console is now ready to be placed on a desk or mounted on a wall.
1.5 Dip Switch Settings (Pool Sensor)
The pool sensor includes dip switches for assigning channel numbers and temperature units. Set these before inserting batteries.
- Channel Number (1-8): The display console supports up to 8 transmitters. Use Dip Switches 1, 2, and 3 to set the channel. Default is Channel 1.
- Temperature Units (°F vs. °C): Use Dip Switch 4 to change the transmitter's display temperature units.
| Dip Switch 1 | Dip Switch 2 | Dip Switch 3 | Dip Switch 4 | Function |
|---|---|---|---|---|
| DOWN | DOWN | DOWN | --- | Channel 1 |
| DOWN | DOWN | UP | --- | Channel 2 |
| DOWN | UP | DOWN | --- | Channel 3 |
| DOWN | UP | UP | --- | Channel 4 |
| UP | DOWN | DOWN | --- | Channel 5 |
| UP | DOWN | UP | --- | Channel 6 |
| UP | UP | DOWN | --- | Channel 7 |
| UP | UP | UP | --- | Channel 8 |
| --- | --- | --- | DOWN | °F |
| --- | --- | --- | UP | °C |
Note: After setting dip switches, press the Reset button on the pool sensor.
1.6 Sensor Placement
Place the sensor in the water within 100' (30m) of the display console. Do not immerse the entire sensor for extended periods. Avoid transmitting through solid earth or ground, and through solid metal barriers. Place the console at least 3' (0.91m) away from computers, TVs, and wireless phones.

Image: Suitable for small ponds, hot tubs, aquariums, swimming pools, spas, and baby baths.
2. Operation
2.1 Display Console Features
The console instantly displays indoor temperature and time upon battery installation. Pool temperature updates within minutes on the appropriate channel.

Image: Display console showing water temperature, time, max/min record, °C/°F switch, indoor temperature, and alarm clock.
The console has three buttons for easy operation: SET, MIN/MAX/-, and CH/+.
2.2 Console SET Mode
Press and hold the SET button for 3 seconds to enter SET mode. The 12/24 hour format will start to flash.
| Item | Setting | Description |
|---|---|---|
| 1 | 12/24 Hour Format | Select 12 or 24 Hour display. |
| 2 | Hour | Adjust hour value. |
| 3 | Minute | Adjust minute value. |
| 4 | Alarm Hour | Adjust alarm hour. Press & hold SET to turn alarm ON/OFF. |
| 5 | Alarm Minute | Adjust alarm minute. Press & hold SET to turn alarm ON/OFF. |
| 6 | Temperature Units | Select °F or °C. |
| 7 | Max/Min Clearing | ON (Clears Daily) or OFF (Manually). |
Use the [+] or [-] key to adjust values. Short press SET to skip. Press SET to exit settings mode.
2.3 Console ALARM Mode
High and low alarms can be set for Channel 1 and Channel 2 only.
- Press CH/+ to switch between Channel 1 and Channel 2.
- Press SET once; HI/Low alarm and ALARM icon will display.
- Press and hold SET for 3 seconds; the HIGH (Max) alarm will flash.
- Use [+] or [-] to adjust the HIGH alarm. Press and hold [+] or [-] for rapid change.
- While flashing, press and hold SET for 3 seconds to turn the alarm ON/OFF.
- Press SET again (do not hold) to set the LOW (Min) temperature alarm.
- Repeat steps 4 and 5 for the LOW alarm.
- Press SET to confirm and exit.
2.4 Console Min/Max Mode
- In normal mode, press MIN/MAX once; the high arrow will flash.
- Press MIN/MAX again; the low arrow will flash.
- Press MIN/MAX again to return to normal mode.
- To reset Max/Min values, press and hold MIN/MAX/- for 3 seconds.
2.5 Console Channel Mode
- Channel Selection: Press CH/+ to switch between remote sensors 1-8. In scroll mode, all detected outdoor sensors display in 5-second intervals.
- Sensor Search Mode: If communication is lost (dashes display), press CH/+ to the lost channel, then press and hold CH/+ for 3 seconds. The remote search icon will display for up to 3 minutes. For new sensors or multiple lost channels, press and hold CH/+ for 5 seconds (on any channel); the icon will display for up to 10 minutes.
2.6 Rate of Change Icon
This icon detects rapid temperature changes. An upward arrow indicates an increase of +2°C (4°F) or more per 30 minutes. A downward arrow indicates a decrease of -2°C (4°F) or less per 30 minutes.
2.7 Temperature Calibration
Calibration allows fine-tuning of temperature readings. A known calibrated source (e.g., mercury thermometer) is recommended for comparison.
- Pool Sensor Temp Calibration:
- Press CH/+ to select the desired pool sensor channel (CH1-8).
- Press and hold SET and CH/+ simultaneously for 5 seconds; the pool sensor temperature will flash.
- Use CH/+ to increase, and MIN/MAX to decrease, the temperature in 0.1° increments. Hold for rapid change.
- Press SET to return to uncalibrated measurement.
- Once the displayed temperature matches your calibrated source, press and hold SET for 3 seconds, or wait 15 seconds for timeout.
- Indoor Temperature Calibration:
- Press and hold SET and MIN/MAX simultaneously for 5 seconds; the indoor temperature will flash.
- Use CH/+ to increase, and MIN/MAX to decrease, the temperature in 0.1° increments. Hold for rapid change.
- Press SET to return to uncalibrated measurement.
- Once the displayed temperature matches your calibrated source, press and hold SET for 3 seconds, or wait 15 seconds for timeout.
Note: Calibrated values are adjusted on the console only; the remote sensor always displays the un-calibrated value.
3. Maintenance
3.1 Pool Sensor Maintenance
During each battery change (every 1-2 years), it is recommended to apply waterproof silicone grease to the seals to maintain their integrity and ensure continued waterproofing.
3.2 General Care
- Keep the display console dry and clean.
- Wipe with a soft, damp cloth if needed. Avoid abrasive cleaners.
- Do not expose the display console to extreme temperatures or direct sunlight for prolonged periods.
4. Troubleshooting
4.1 Wireless Remote (Thermometer) Not Reporting / Dashes on Display
- Reacquire Signal: Press and hold the CH/+ button for 3 seconds. The remote search icon will display.
- Distance: Move the sensor closer to the display console. Maximum line of sight transmission is 300' (100m) in open air, typically 100' (30m) in real-world conditions.
- Proximity: If the sensor is too close (less than 5'/1.5m), move it further away.
- Sensor Check: Ensure the pool sensor LCD display is working and the transmitter light flashes once every 60 seconds.
- Batteries: Install a fresh set of batteries (lithium for cold weather).
- Obstructions: Ensure remote sensors are not transmitting through solid metal (RF shield) or earth barriers.
- Interference: Move the display console away from electrical noise generating devices (computers, TVs, other wireless transmitters).
- Location: Move the remote sensor to a higher or closer location.
4.2 Indoor and Pool Sensor Temperature Discrepancy
- Stabilization: Allow up to one hour for sensors to stabilize due to signal filtering. Temperatures should agree within 4°F/2°C (accuracy ±2°F/1°C).
- Calibration: Use the calibration feature to match indoor and outdoor temperatures to a known source.
4.3 Display Console Contrast is Weak
- Batteries: Replace console batteries with a fresh set.
5. Specifications
5.1 Wireless Specifications
- Line of Sight Transmission: 300' (100m) in open air, 100' (30m) under most conditions.
- Frequency: 433 MHz
- Update Rate: 60 seconds
5.2 Measurement Specifications
| Measurement | Range | Accuracy (Resolution) |
|---|---|---|
| Indoor Temperature | 32 to 140°F (0° to 60°C) | ±2°F/±1°C (0.1°F/°C) |
| Outdoor Temperature | -40 to 140°F (-40° to 60°C) | ±2°F/±1°C (0.1°F/°C) |
5.3 Power Consumption
- Base Station (Display Console): 2 x AAA 1.5V Alkaline or Lithium batteries (not included). Minimum 12 months battery life.
- Pool Sensor: 4 x AAA 1.5V Alkaline or Lithium batteries (not included). Minimum 12 months battery life (use lithium batteries in cold weather climates less than -4°F/-20°C).
5.4 Physical Dimensions
- Display Console: 4.76"x2.9"x0.59" (12.1x7.5x1.5cm)
- Pool Transmitter (Sensor): 6.9"x4.2"x3.7" (17.5x10.6x9.5 cm)
5.5 Other Features
- Waterproof Level: IPX8
- Display Type: DIGITAL
- Display Size: 2.0 - 3.9 Inches

Image: IPX8 Waterproof, -40°F to 140°F Temperature Range, Double Silicone Seal, Fast Refresh.
6. User Tips
- Optimal Placement: For best wireless transmission, ensure a clear line of sight between the pool sensor and the display console. Avoid placing the console near large metal objects or thick walls.
- Battery Life: Always use fresh, high-quality batteries. Consider lithium batteries in colder climates for extended performance.
- Waterproofing: When changing batteries in the pool sensor, always double-check that the red gaskets are perfectly seated and the lids are securely tightened with the wrenches to maintain its IPX8 waterproof rating.
- Interference: If you experience intermittent readings, try relocating the display console or the sensor slightly to avoid potential radio frequency interference from other electronic devices.
7. Warranty and Support
7.1 Limited One Year Warranty
Urageuxy warrants that all products it manufactures are of good material and workmanship, and free of defects when properly installed and operated for a period of one year from the date of purchase. This warranty is expressly in lieu of all other warranties, express or implied, including merchantability and fitness for a particular purpose. Urageuxy disclaims all liability for special, consequential, or incidental damages. The purchaser assumes all liability for consequences arising from use or misuse. No person is authorized to assume any other liability or modify these terms.
7.2 Customer Support
For assistance, please have your model number (FT0803) available and contact customer support via email:
E-mail: ucweatherstation@gmail.com
7.3 FCC Information
This device complies with part 15 of FCC rules. Operation is subject to two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device. It generates, uses, and can radiate radio frequency energy. If not installed and used according to instructions, it may cause harmful interference to radio communications. If interference occurs, users are encouraged to try corrective measures such as reorienting the receiving antenna, increasing separation between equipment and receiver, connecting equipment to a different circuit, or consulting a dealer/technician. Unauthorized modifications could void the user's authority to operate the equipment.