Model: KS Rotary Panel V1-S

Brand: Skydance

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Skydance KS Rotary Panel and V1-S Constant Voltage Triac Dimmers. These devices are designed for controlling LED lighting systems, offering precise dimming capabilities and compatibility with various control methods.

Skydance V1-S Triac Dimmer and KS Rotary Panel Dimmer
Overview of the V1-S Constant Voltage Triac Dimmer and KS AC Triac Rotary Panel Dimmer.

The V1-S is a constant voltage Triac dimmer, suitable for 12-48VDC LED systems, while the KS Rotary Panel is an AC Triac RF dimmer for 100-240VAC systems. Both offer smooth dimming and reliable performance.

2. Safety Information

WARNING: Electrical installation should only be performed by qualified personnel. Ensure power is disconnected before installation or maintenance to prevent electric shock.

  • Always disconnect power before installing or servicing.
  • Ensure all connections are secure and correct to prevent damage to the device or connected lighting.
  • Do not exceed the maximum load power specified for the dimmer.
  • The products shall not be stacked. Maintain a distance of at least 20cm between products to ensure proper heat dissipation and extend lifespan.
  • Do not install the product close to a switching power supply (maintain ≥ 20cm interval) to avoid radiation interference.

3. Package Contents

Your package includes the selected dimmer model. Please verify that all components are present and undamaged upon receipt.

  • 1x Skydance V1-S Constant Voltage Triac Dimmer (if selected)
  • 1x Skydance KS AC Triac Rotary Panel Dimmer (if selected)

4. Specifications

4.1. V1-S Constant Voltage Triac Dimmer

V1-S Technical Parameters and Dimensions
Technical parameters, mechanical structures, and wiring diagram for the V1-S dimmer.
V1-S Technical Parameters
Category Parameter Value
Input and OutputInput voltage12-48VDC
Input current15A
Output voltage12-48VDC
Output current1CH, 15A
Output power180W/360W/540W/720W (12V/24V/36V/48V)
Output TypeConstant voltage
Dimming DataInput signal100-240VAC + AC Push-Dim
Dimming range0-100%
Dimming curveLogarithmic
EnvironmentOperation temperature-30°C ~ +55°C
Case temperature (Max.)Tc +85°C
ProtectionIP ratingIP20
Safety and EMCEMC standardEN IEC 55015/EN IEC 61547
Safety standardEN 61347-1/-2, EN 62493
CertificationCE, RoHS
WarrantyWarranty5 years
ProtectionFeaturesReverse polarity, Over current, Short circuit, Over temperature

4.2. KS AC Triac Rotary Panel Dimmer

KS Rotary Panel Dimmer Technical Parameters and Dimensions
Technical parameters, mechanical structures, and wiring diagram for the KS Rotary Panel Dimmer.
KS Technical Parameters
Category Parameter Value
Input and OutputInput voltageAC100-240V
Output voltageAC100-240V
Output currentMax 1.5A
Output power150-360W
Input SignalTypeRotary knob + RF 2.4GHz
RF Control Distance10m (barrier-free space)
EnvironmentOperation Temperature-30°C ~ +55°C
Case Temperature (Max.)Tc +85°C
Safety and EMCEMC standardEN 301 489-1 V2.2.3, EN 301 489-17 V3.2.4
Safety standardEN 62368-1:2020+A11:2020
Radio Equipment (RED)EN 300 328 V2.2.2
CertificationCE, EMC, LVD, RED
WarrantyWarranty3 years
MechanicalSizeL12x W11.2 x H60mm
Gross weight0.113kg

5. Installation and Setup

Careful wiring is crucial for proper function and safety. Please follow the diagrams and instructions below.

5.1. Wiring Preparation

  • Wiring can be solid or stranded with a cross-sectional area of 0.5 to 2.0 mm².
  • Conventional 1mm² wire can withstand 10A output current.
  • Ensure all terminals are tightened after installation. Loose connections can lead to high contact resistance and overheating, potentially burning the terminals.
  • The output power of a constant voltage power supply should be at least 1.2 times that of the output load (light strip). Insufficient power can cause automatic flickering or shaking of the light.

5.2. V1-S Dimmer Wiring Diagram

The V1-S dimmer is designed for constant voltage LED strips. Connect it as shown below. Before connecting, identify the neutral line input for the Triac dimmer.

V1-S Wiring Diagram for Single Color LED Strip
Wiring diagram for V1-S Constant Voltage Triac Dimmer with a single color LED strip and constant voltage power supply.

Connection Points:

  • L, N: AC Input (100-240V)
  • A1, A2: AC Push Switch Input (for external push switch)
  • LED+, LED-: LED Output (12-48VDC)

The V1-S dimmer can be connected to an external AC push switch for on/off and dimming functions.

5.3. KS Rotary Panel Dimmer Wiring Diagram

The KS Rotary Panel Dimmer is an AC Triac RF dimmer. It can be connected to dimmable LED lamps, traditional incandescent, and halogen lights.

KS Rotary Panel Dimmer Wiring Diagram
Wiring diagram for KS AC Rotary Panel Dimmer with dimmable LED light.

Connection Points:

  • INPUT L, N: AC Input (100-240V)
  • OUTPUT L, N: Dimmable LED Light Output

Caution: Please carefully ensure all wire connections and polarities are correct and secure before applying power, otherwise this controller will be damaged.

The KS dimmer also features a DIP switch for setting leading edge or trailing edge phase-cut dimming and minimum brightness.

5.4. System Compatibility Overview

Skydance AC Triac Dimming Series System Overview
Overview of the Skydance AC Triac Dimming Series, showing compatibility with various control inputs and lighting types.

The Skydance AC Triac control system supports various dimming methods including RF Triac dimmers, Triac panel dimmers, and push switches, compatible with single color dimmable LED lamps, traditional incandescent, and halogen lights.

6. Operating Instructions

Both V1-S and KS dimmers offer intuitive control for your lighting. The KS dimmer uses a rotary knob, while the V1-S can be controlled via an external AC push switch or a compatible RF remote.

6.1. KS Rotary Panel Dimmer Functions

KS Rotary Panel Dimmer Functions and Settings
Detailed functions and settings for the KS Rotary Panel Dimmer, including load types, knob functions, and matching procedures.
  • Knob Function:
    • Push: Turn on or turn off the light.
    • Rotate: Rotate the knob to adjust brightness (256 levels, 0-100%).
    • Long Push (1-5s): Continuously adjust brightness.
  • Leading Edge or Trailing Edge Dimming Setting: Select the appropriate dimming method (forward-phase or reverse-phase) using the DIP switch on the dimmer, according to your dimmable LED light or driver.
  • Min Brightness Setting: Use the 'Min set' button to set the minimum brightness level. Short press 1-6 times to set 5%, 10%, 15%, 20%, 25%, or 30% minimum brightness. Long press for 2s or 8s to reset or output 100% brightness automatically.
  • Light On/Off Fade Time: Long press the 'Match' key for 5s to set the light on/off fade time to 3s. Long press again for 10s to restore factory default.

6.2. V1-S AC Push-Dim Function

The V1-S dimmer supports control via an external AC push switch:

  • Short press: Turns the light on or off.
  • Long press (1-6s): Press and hold for stepless dimming. Each subsequent long press reverses the dimming direction.
  • Dimming Memory: The light returns to its previous dimming level even after being switched off and on, or after a power failure.
  • Synchronization: If multiple V1-S controllers are connected to the same push switch, a long press for more than 10s will synchronize all lights in the group to 100% brightness. This eliminates the need for additional synchrony wiring in larger installations. It is recommended not to connect more than 25 controllers to a single push switch, and the maximum wire length from the push switch to the controller should not exceed 20 meters.

6.3. Triac Dimming Input Considerations

The AC100-240V dimming signal input can achieve 0%-100% brightness output, proportional to the input dimming signal. If the brightness does not reach 0% or 100%, check if the input voltage can achieve the lowest or highest voltage. Different Triac dimmers from various suppliers may have different minimum dimming levels. To dim to 1%, ensure your dimmer supports this level. The product uses an analog method to detect the dimming signal and adjusts brightness consistency between different Triac dimmers through a potentiometer. Both Triac dimmer and Push switch can be connected simultaneously for more user-friendly options. If the product is used with the Push-Dim interface prior to the Triac interface, the Triac dimming signal should change over 10% to return Triac control.

6.4. Product Demonstration Video

A demonstration of the Skydance Triac control system, showcasing various dimming methods and compatible devices.

7. Maintenance

The Skydance dimmers are designed for long-term reliability with minimal maintenance. Follow these guidelines to ensure optimal performance:

  • Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
  • Avoid exposing the device to excessive moisture or extreme temperatures.
  • Regularly check wiring connections to ensure they remain secure.
  • Do not attempt to open or repair the device yourself. Refer to qualified service personnel for any repairs.

8. Troubleshooting

If you encounter issues with your dimmer, please refer to the following common problems and solutions:

  • Light Flickering or Shaking:
    • Ensure the power supply's output power is at least 1.2 times the load's power.
    • Check for loose wiring connections.
  • Dimming Range Issues (not reaching 0% or 100%):
    • Verify the input voltage is within the specified range.
    • For Triac dimmers, ensure the connected LED driver or lamp is compatible with the dimmer's dimming type (leading edge/trailing edge).
    • Adjust the minimum brightness setting if the light does not dim to the desired low level.
  • Device Not Responding:
    • Check all power connections.
    • Ensure the correct input signal is being provided (AC push switch or RF remote).
    • If using an RF remote, ensure it is properly matched with the dimmer.
  • Overheating:
    • Ensure adequate ventilation around the dimmer.
    • Do not stack multiple dimmers. Maintain at least 20cm separation.
    • Verify the load does not exceed the maximum specified power.

9. User Tips

  • Wiring Caution (KS Rotary Panel): Some users have reported that the 'L' (Live) and 'N' (Neutral) input labels on the device might be switched. Always use the outside connections for the Live input and dimmed Live output. The left input connection and the right output connection are typically for the neutral wire. You usually only need to connect the neutral input wire, as the light fixture often has its own neutral wire in the ceiling box. Always double-check with a multimeter if unsure.
  • Remote Pairing: Pairing with an RF remote is generally straightforward and works effectively.
  • Dimming Performance: The dimming performance with compatible LED lights is reported to be good.

10. Warranty and Support

The V1-S Constant Voltage Triac Dimmer comes with a 5-year warranty, and the KS AC Triac Rotary Panel Dimmer comes with a 3-year warranty. This covers defects in materials and workmanship under normal use. For technical support, troubleshooting assistance, or warranty claims, please contact your retailer or the manufacturer directly.

A detailed user manual in PDF format is available for download: User manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.