1. Introduction
This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of your MASTFUYI Digital Wireless Pool Thermometer. Please read this manual thoroughly before using the product to ensure proper function and longevity.
Figure 1: Product Overview - Wireless Pool Thermometer with Display Console. Highlights include a transmission range of up to 330ft (open area) or 100ft (most conditions), accuracy of ±2°F, double silicone seal, IPX8 waterproof rating, temperature range of -40°F to 140°F, and fast refresh rate.
Figure 2: Key Features - Water temperature, time display, Max/Min record, °C/°F switch, indoor temperature monitoring, and alarm clock functionality.
2. Getting Started
Note: Power up the pool sensor first and then the Display Console second. Do not press any button until all data has been received.
2.1 Parts List
Figure 3: Included Components - Pool thermometer, display console, two wrenches, and user manual.
- 1 x Display Console: Size: 4.76"x2.9"x0.59" (12.1x7.5x1.5cm), LCD Size: 2.99"x1.77" (7.6x4.5cm)
- 1 x Pool Transmitter: Size: 6.9"x4.2"x3.7" (17.5x10.6x9.5cm)
- 1 x Manual
- 2 x Wrench: (for Upper lid and Lower lid)
Note: The pool sensor is very tight for waterproofing purposes. Please use the provided wrenches to open and close it easily.
3. Setup
3.1 Pool Sensor (Transmitter) Battery Installation
Note: To avoid permanent damage, observe battery polarity before inserting batteries. For sensor temperatures below -4°F (-20°C), fresh lithium batteries are recommended.
- To insert the batteries, twist the KEY to unlock, remove the KEY, and then twist the main body of the sensor by removing the upper lid and lower lid with the included wrench.
- Refer to the Wrench Usage Instructions to open easily along the arrow direction.
- Install 4 x AAA batteries, paying close attention to battery polarity.
- Take out the desiccant pack from its plastic bag and place it into the main body of the sensor. This helps absorb moisture and keeps the main body dry.
- Before closing the battery door, ensure both red colored gaskets are properly seated in their tracks. Failure to properly seal the floating thermometer will result in water leakage and damage.
- To close the lid, twist the upper lid and lower lid with the wrench until it is firmly locked and the key hole is aligned. Insert the key and turn 90 degrees to lock the lid.
- A tether can be attached to the key hole to fix the sensor in a certain range (tether not included).
Figure 4: Pool Sensor Internal Components and Opening Mechanism. Shows dip switches, reset button, and how to twist the key and body to open.
Note: Place the sensor in the water and ensure it is within the effective transmission range (100' / 30m under most conditions) from the display console. Do not immerse the entire sensor into the water for extended periods.
3.2 Wrench Usage Instructions
The wrench should be faced up with the word “UP” facing upwards.
- The small wrench and the lower cover must be attached tightly.
- The big wrench and the upper cover must match tightly, especially the arrow positioning.
- Ensure the two wrenches are properly matched to 90 degrees for easy opening.
- Using your left hand, hold the big wrench and turn the lid counter-clockwise while holding the small wrench firmly with your right hand.
Note: You need to hold the big wrench with your right thumb to prevent it from slipping.
3.3 Display Console Battery Installation
- Remove the battery door on the back of the console.
- Insert 2xAAA (alkaline or lithium, avoid rechargeable) batteries.
- Close the battery door. The console can be placed on a desk or mounted on a wall.
- Do not touch any buttons until all data has been received.
Note: Move the sensor about 5' to 10' (1.5m to 3m) away from the display console. If the sensor is too close, it may not be received by the display console.
4. Operating Instructions
4.1 Pool Sensor Features
Note: If you have more than one remote sensor, ensure they are all powered up and transmitting on different channels.
- The pool sensor includes dip switches for assigning channel numbers (1-8).
- The pool sensor includes a reset button. If the display does not power up after inserting the batteries, press the reset button.
- All four dip switches are shown in the OFF position by default.
4.1.1 Setting Channel Number and Temperature Units
The display console supports up to 8 transmitters. To set each channel number (default is Channel 1), change Dip Switches 1, 2, and 3 as referenced in Table 1. To change the transmitter display temperature units (°F vs. °C), change Dip Switch 4 as referenced in Table 1.
| DIP SWITCH 1 | DIP SWITCH 2 | DIP SWITCH 3 | DIP SWITCH 4 | Function |
|---|---|---|---|---|
| DOWN | DOWN | DOWN | --- | Channel 1 |
| DOWN | DOWN | UP | --- | Channel 2 |
| DOWN | UP | DOWN | --- | Channel 3 |
| DOWN | UP | UP | --- | Channel 4 |
| UP | DOWN | DOWN | --- | Channel 5 |
| UP | DOWN | UP | --- | Channel 6 |
| UP | UP | DOWN | --- | Channel 7 |
| UP | UP | UP | --- | Channel 8 |
| --- | --- | --- | DOWN | °F |
| --- | --- | --- | UP | °C |
Note: Set up dip switches before inserting batteries. Press the Reset button after changing the Channel number or C/F unit.
After inserting batteries, the remote sensor's LED indicator will light for 4 seconds, then flash every 60 seconds, indicating data transmission.
Verify the correct channel number (CH) and temperature units (°F vs. °C) are on the display.
4.2 Display Console Features
When batteries are installed (without pressing any buttons), the console will instantly display indoor temperature and time. The pool temperature will update on the display within a few minutes on the appropriate channel.
Note: If the remote does not update, refer to the troubleshooting guide in Section 7.
4.2.1 Console SET Mode
Note: The console has three buttons for easy operation: SET button, MIN/MAX/- button, and CH/+ button.
To enter SET mode, press and hold the SET key for 3 seconds. The 12/24 hour format will start to flash.
| Step | Action (Short press SET) | Setting (Press [+] or [-]) |
|---|---|---|
| 1 | 12/24 Hour Format | 12 Hour or 24 Hour Format |
| 2 | Hour | Hour value up or down |
| 3 | Minute | Minute value up or down |
| 4 | Alarm Hour | Alarm Hour value up or down. (While flashing, press and hold SET for 3 seconds to turn alarm ON/OFF.) |
| 5 | Alarm Minute | Alarm Minute value up or down. (While flashing, press and hold SET for 3 seconds to turn alarm ON/OFF.) |
| 6 | Temperature Units | °F or °C |
| 7 | Max/Min Clearing | ON (Clears Daily) or OFF (Manually) |
Press the SET key to exit the settings Mode.
4.2.2 Console ALARM Mode
Alarm settings are available for Channel 1 and Channel 2 only.
| Channel | Condition | HI ALARM °C(°F) | LOW ALARM °C(°F) |
|---|---|---|---|
| 1 | OFF | 38(100) | 15(60) |
| 2 | OFF | 43(110) | 32(90) |
View and Set HI/Low Alarm
- Press the CH/+ button to switch the display between Channel 1 and Channel 2.
- Press the SET button once; the HI/Low alarm and alarm icon will be displayed.
- Press and hold the SET button for 3 seconds, and the temperature HIGH (Max) alarm will flash.
- Press the [+] or [-] button to increase or decrease the HIGH alarm. Press and hold the [+] or [-] button to change rapidly. While the alarm value is flashing, press and hold the SET button for three seconds to turn the alarm ON and OFF. The alarm icon will appear when set, and disappear when disabled.
- Press (do not hold) the SET button again to set the LOW (Min) temperature alarm. The LOW alarm for temperature will flash.
- Press the [+] or [-] button to increase or decrease the LOW alarm. Press and hold the [+] or [-] button to change rapidly. While the alarm value is flashing, press and hold the SET button for three seconds to turn alarm ON and OFF. The alarm icon will appear when set, and disappear when disabled. Press SET button to confirm and exit.
4.2.3 Console Min/Max Mode
- In normal mode, press the MIN/MAX button once and the high arrow will flash.
- Press the MIN/MAX button again and the low arrow will flash.
- To reset the Max/Min values, press and hold the MIN/MAX- button for 3 seconds.
4.2.4 Console Channel Mode
Channel Selection
Press the CH/+ button to switch the display between remote sensors 1 through 8, and scroll mode. In scroll mode, all detected outdoor sensors will be displayed in five-second intervals.
Sensor Search Mode
If any of the sensor communication is lost, dashes (--.-) will be displayed on the screen. To reacquire the signal:
- If a specific channel is lost, press the CH/+ button to display this channel, then press and hold the CH/+ button for 3 seconds. The remote search icon will be constantly displayed for up to 3 minutes. Once the signal is reacquired, the remote search icon will turn off, and the current values will be displayed.
- If new sensors are added, subtracted, or multiple sensor channels are lost, press and hold the CH/+ button for 5 seconds (on any channels). The remote search icon will be constantly displayed for up to 10 minutes. Once the signal is reacquired, the remote search icon will turn off, and the current values will be displayed.
4.2.5 Rate of Change Icon
The rate of change icon detects rapid changes in remote temperature. If the arrow points upward, the temperature increases at a rate of +2°C (4°F) per 30 minutes (or greater). If the arrow points downward, the temperature decreases at a rate of -2°C (4°F) per 30 minutes (or less).
4.2.6 Temperature Calibration
Pool Sensor Temp Calibration
- Prior to entering calibration mode, press the CH/+ button to select the pool temperature sensor (CH1-8) you want to adjust.
- To enter temperature calibration mode, press and hold the SET and CH/+ buttons simultaneously for 5 seconds. The pool sensor temperature value will begin flashing. Press the CH/+ button to increase the temperature and press the MIN/MAX button to decrease the temperature reading in 0.1° increments. To rapidly increase (or decrease) the temperature reading, press and hold the CH/+ or MIN/MAX button.
- To return the temperature to the actual or uncalibrated measurement, press the SET button.
- Once the displayed temperature equals the calibrated source, press and hold the SET button for three seconds, or wait 15 seconds for timeout. The temperature value will stop flashing.
Indoor Temperature Calibration
- To enter indoor temperature calibration mode, press and hold the SET and MIN/MAX buttons simultaneously for 5 seconds. The IN temperature value will begin flashing. Press the CH/+ button to increase the temperature and press the MIN/MAX button to decrease the temperature reading in 0.1° increments. To rapidly increase (or decrease) the temperature reading, press and hold the CH/+ or MIN/MAX button.
- To return the temperature to the actual or uncalibrated measurement, press the SET button.
- Once the displayed temperature equals the calibrated source, press and hold the SET button for three seconds, or wait 15 seconds for timeout. The temperature value will stop flashing.
Note: The calibrated value can only be adjusted on the console. The remote sensor always displays the un-calibrated or measured value.
Calibration is used to fine-tune or correct for sensor errors. It is optional and only useful if you have a known calibrated source. Do not compare readings to sources like the internet, radio, television, or newspapers, as they are often in different locations and update infrequently.
Discussion: Temperature errors can occur when a sensor is placed too close to a heat source (e.g., building structure, ground, or trees).
To calibrate temperature, a mercury or red spirit (fluid) thermometer is recommended. Bi-metal (dial) and other digital thermometers are not ideal due to their own margin of error. Local weather stations are also poor sources due to location, timing, and potential calibration errors.
5. Maintenance
5.1 Pool Sensor Maintenance
During each battery change (every 1-2 years), it is recommended to apply waterproof silicone grease to the seals. Silicone grease is available at most hardware and pool stores.
Note: Not recommended for covered spas. Wireless signals will not penetrate solid metal or earth.
6. Troubleshooting Guide
6.1 Wireless Remote (Thermometer) Not Reporting to Console (Dashes on Display)
Solution:
- If any sensor communication is lost, dashes (--.-) will be displayed. To reacquire the signal, press and hold the CH/+ button for 3 seconds. The remote search icon will be constantly displayed. Once the signal is reacquired, the icon will turn off, and current values will be displayed.
- The maximum line of sight transmission range is 300' (100m) and 100' (30m) under most conditions. Move the sensor assembly closer to the display console.
- If the sensor assembly is too close (less than 5' / 1.5m), move the sensor assembly away from the console.
- Ensure the pool sensor LCD display is working and the transmitter light is flashing once per 60 seconds.
- Install a fresh set of batteries in the remote thermometer. For cold weather environments, install lithium batteries.
- Ensure remote sensors are not transmitting through solid metal (acts as an RF shield) or earth barriers (e.g., down a hill).
- Move the display console away from electrical noise-generating devices, such as computers, TVs, and other wireless transmitters or receivers.
- Move the remote sensor to a higher location.
- Move the remote sensor to a closer location.
6.2 Indoor and Pool Sensor Temperature Do Not Agree in the Same Place
Solution:
- Allow up to one hour for the sensors to stabilize due to signal filtering. The indoor and pool sensor temperature should agree within 4°F/2°C (the sensor accuracy is ±2°F/1°C).
- Use the calibration feature to match the indoor and outdoor temperature to a known source.
6.3 Display Console Contrast is Weak
Solution:
- Replace console batteries with a fresh set of batteries.
7. Specifications
7.1 Wireless Specifications
- Line of sight wireless transmission (in open air): 300' (100m), 100' (30m) under most conditions.
- Frequency: 433 MHz
- Update Rate: 60 seconds
7.2 Measurement Specifications
| Measurement | Range | Accuracy (Resolution) |
|---|---|---|
| Indoor Temperature | 32 to 140 °F (0° - 60°C) | ±2°F / ±1°C (0.1°F/°C) |
| Outdoor Temperature | -40 to 140 °F (-40° - 60°C) | ±2°F / ±1°C (0.1°F/°C) |
7.3 Power Consumption
- Base station (display console): 2 x AAA 1.5V Alkaline or Lithium batteries (not included). Minimum 12 months battery life.
- Pool sensor: 4 x AAA 1.5V Alkaline or Lithium batteries (not included). Minimum 12 months battery life (use lithium batteries in cold weather climates less than -4°F / -20°C).
Intermittent reception and multiple sensors may reduce battery life.
8. User Tips
- For optimal wireless performance, ensure a clear line of sight between the pool sensor and the display console. Avoid placing the console near large metal objects or electronic devices that may cause interference.
- When changing batteries, always replace all batteries with new ones of the same type to ensure consistent performance.
- Regularly check the sensor's seals and apply silicone grease as recommended to maintain its IPX8 waterproof rating.
- If you notice inconsistent readings, try recalibrating the sensor against a known accurate thermometer.
- Consider the placement of the pool sensor to avoid direct sunlight for prolonged periods, which can affect battery life and sensor accuracy.
9. Warranty & Support
9.1 Customer Support
Urageuxy customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us via:
- E-mail: ucweatherstation@gmail.com
For the full user manual in PDF format, please refer to the official document: MASTFUYI Wireless Pool Thermometer User Manual (PDF)
9.2 FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.
9.3 Limited One Year Warranty
At Urageuxy, we warrant that all products it manufactures are of good material and workmanship, and are free of defects when properly installed and operated for a period of one year from the date of purchase.
The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose.
Urageuxy expressly disclaims all liability for special, consequential, or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Urageuxy further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Urageuxy's products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm, or corporation is authorized to assume for Urageuxy any other liability in connection with the sale of its products.
Furthermore, no person, firm, or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Urageuxy. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.