SONGGER ZTS-300L

Contents

SONGGER ZTS-300L Total Solar Irradiance Sensor User Manual

Model: ZTS-300L

1. Introduction

The SONGGER ZTS-300L is a photoelectric solar radiation sensor designed for continuous measurement of total solar irradiance within the spectral range of 400 to 1100 nm. It is suitable for solar energy monitoring, agricultural research, environmental observation, and building material performance analysis. The sensor supports multiple industrial output signals and is designed for stable long-term outdoor operation.

ZTS-300L Total Solar Radiation Sensor with key specifications
Figure 1: ZTS-300L Total Solar Radiation Sensor with key specifications: Range 0-2000W/m², Power 7-30VDC, Output RS485/4-20mA/0-5V/0-10V, Cable 60/70cm, Temp -20~60°C.
Photovoltaic Solar Total Radiation Sensor illustrating its photoelectric principle
Figure 2: Photovoltaic Solar Total Radiation Sensor illustrating its photoelectric principle and high-precision photosensitive components for wide-spectrum absorption and stability.

2. Specifications

AttributeValue
Brand NameSONGGER
DIY SuppliesElectrical
Measurement PrinciplePhotoelectric
Spectral Range400~1100nm
Measurement Range (RS485)0~2000W/m²
Measurement Range (Analog)0~1800W/m²
Output Signal OptionsRS485 / 4-20mA / 0-5V / 0-10V
Power Supply (RS485)7~30VDC
Power Supply (Analog)10~30VDC
Recommended Rated Voltage24 VDC
Response Time≤10s
Resolution1W/m²
Accuracy±5%
Non-linearity (RS485)Less than ±2%
Non-linearity (Analog)Less than ±3%
Annual Stability (RS485)≤±2%
Annual Stability (Analog)≤±3%
Cosine Response Error≤±10%
Operating Temperature-25℃~60℃
Humidity Range0%~100% RH
Load Resistance (Current Output)≤600 Ω
Load Resistance (Voltage Output)≤250 Ω
Housing MaterialFull Aluminum Housing
Protective CoverHigh-transparency optical dome
Protection RatingIP67
Cable Length60 cm standard, customizable
Battery IncludedNo
High-concerned chemicalNone
OriginMainland China
ZTS-300L sensor with specifications for 0-5V output version
Figure 3: ZTS-300L sensor with specifications for 0-5V output version: Range 0-1800W/m², Power 10-30VDC, Output 0-5V, Cable 50cm, Temp -25~60°C.

3. Setup and Installation

3.1 Preparation

  • Verify that the supplied power voltage matches the selected output type.
  • Ensure correct wiring according to the output mode.
  • Install the sensor in an open area free from shading or reflective interference.
  • Use the integrated level to ensure the sensor is horizontally aligned unless a specific tilt angle is required for the application.
ZTS-300L sensor highlighting its built-in level gauge and adjustment knob
Figure 4: ZTS-300L sensor highlighting its built-in level gauge and adjustment knob for precise installation. Features include corrosion-resistant, weatherproof, full aluminum housing, and IP67 protection.

4. Operation

4.1 Connecting the Sensor

Connect the power supply and output lines to the monitoring or data acquisition system. For RS485 output, configure communication parameters according to the system requirements.

4.2 Data Reading

  • After powering on, allow the sensor to stabilize for several minutes before recording data.
  • For analog outputs (4-20mA, 0-5V, 0-10V), read the corresponding current or voltage signal and convert it proportionally to the selected measurement range.
  • For RS485 output, read the digital irradiance value directly from the communication interface. Ensure scaling parameters in the control system match the configured measurement range.

5. Storage and Maintenance

  • Store the sensor in a dry and ventilated environment when not in use.
  • Avoid long-term exposure to high humidity or corrosive gases.
  • Clean the optical dome periodically using a soft lint-free cloth and clean water.
  • Regularly inspect mounting stability and cable integrity.
  • Calibration is recommended periodically according to application requirements.
Close-up of the ZTS-300L sensor's transparent dust cover
Figure 5: Close-up of the ZTS-300L sensor's transparent dust cover, illustrating its special surface treatment to prevent dust adhesion, crucial for accurate readings and easy maintenance.

6. Troubleshooting

This section provides general guidance for common issues. For complex problems, contact technical support.

6.1 No Output / Incorrect Readings

  • Check Power Supply: Ensure the sensor is receiving the correct voltage (7-30VDC for RS485, 10-30VDC for analog) and that polarity is correct.
  • Verify Wiring: Confirm all connections are secure and match the specified wiring diagram for your chosen output type (RS485, 4-20mA, 0-5V, 0-10V).
  • Inspect Optical Dome: Ensure the transparent dust cover is clean and free from obstructions like dust, snow, or condensation.
  • Stabilization Time: Allow several minutes after powering on for the sensor to stabilize before taking readings.
  • Communication Parameters (RS485): For RS485 versions, verify that the communication parameters (baud rate, parity, data bits, stop bits) in your data acquisition system match the sensor's configuration.
  • Scaling Parameters (Analog): For analog outputs, ensure your data acquisition system's scaling parameters correctly convert the current/voltage signal to W/m².

6.2 Sensor Not Level

  • Use the built-in level gauge and adjustment knobs to ensure the sensor is horizontally aligned for accurate measurements, unless a specific tilt is required.

7. User Tips

  • Thoroughly Read the Manual: Users have found comprehensive documentation very helpful. Taking the time to read this manual thoroughly before installation and operation can prevent common issues and ensure optimal performance.
  • Optimal Placement: Always strive for an open installation area, free from any potential shading or reflective surfaces that could interfere with accurate solar radiation measurements.
  • Regular Cleaning: Keep the optical dome clean. Even small amounts of dust or debris can affect readings. A soft, lint-free cloth with clean water is usually sufficient.

8. Safety and Precautions

8.1 General Precautions

  • Ensure correct polarity during wiring to avoid permanent damage.
  • Do not exceed the specified supply voltage range.
  • Avoid mechanical shock or impact to the optical dome.
  • Keep the optical surface clean and free from dust, snow, or condensation.
  • Do not use solvents or corrosive chemicals for cleaning.
  • Operate only within the specified temperature (-25℃~60℃) and humidity (0%~100% RH) range.
  • Disconnect power before performing maintenance.

8.2 Important Warnings

WARNING!

  • Installation and wiring must be performed by qualified technical personnel.
  • Incorrect wiring may cause equipment damage or measurement errors.
  • This device is intended for low-voltage DC systems only.
  • Do not modify or disassemble the product.
  • Keep out of reach of children.
  • Proper disposal: Follow WEEE directives for electronic waste.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.

9. Warranty and Support

For warranty information, please refer to the terms and conditions provided by your point of purchase or contact the seller directly. For technical support, please reach out to the manufacturer or authorized distributor.

For a comprehensive user manual, including detailed wiring diagrams and advanced configurations, please refer to the official PDF document available at: ZTS-300L User Manual (PDF).

10. Frequently Asked Questions (FAQ)

No specific FAQ content is available at this time. Please refer to the troubleshooting section or contact support for assistance.