1. Introduction
The IKSLED PIR Motion Sensor Light Switch is an infrared-based automatic control product designed for convenient, safe, and energy-efficient lighting. It detects changes in the human infrared spectrum. When a person enters its sensing range, the switch automatically connects the load (turns on the light). The light remains on as long as movement is detected within the range. After the person leaves, the switch automatically disconnects the load after a set delay, turning off the light.
2. Safety Information
Please read and understand all instructions before installation and use. Improper installation can lead to electrical shock or fire hazards. Always disconnect power at the circuit breaker before performing any electrical work.
- Ensure the power supply is turned off before installation or maintenance.
- Installation should be performed by a qualified electrician if you are unsure.
- Do not exceed the maximum load capacity of 40W.
- This product is rated IP22, meaning it is protected against solid objects over 12.5mm and vertically falling drops of water. It is not suitable for direct exposure to heavy rain or submersion.
3. Product Features
- Automatic Control: Infrared-based detection for automatic light activation.
- Energy Efficiency: Lights turn on when a person is present and off after they leave.
- Auto Metering: Features no light detection in bright conditions (factory default), with auto-locking during daylight or in well-lit environments to prevent unnecessary activation.
- Adjustable Settings: (Note: Some product variations may have fixed settings and lack physical adjustment switches. Please check your specific unit.)
- Adjustable illumination threshold (Deepdark: <2LUX, Lightdark: <25LUX, Allday).
- Adjustable time delay (15 seconds, 45 seconds, 5 minutes).
- Wide Application: Suitable for various lighting fixtures including LED ceiling lights, downlights, panel lights, energy-saving lamps, and traditional bulb lamps.
- Versatile Use: Ideal for stairwells, corridors, lobbies, courtyards, garages, and basements.
4. Specifications
| Parameter | Value |
|---|---|
| Working Voltage | AC85-265V |
| Controllable Load | Under 40W |
| Inclination Angle | 120 degrees |
| Sensing Distance | 3-5 meters |
| Recommended Installation Height | 2-3 meters (up to 3.5 meters) |
| Waterproof Rating | IP22 |
| Recommended Hole Size | 20mm |
| Item Size (Diameter x Height) | D28*H37mm |
| Single Item Weight | 12g |
5. Installation
The sensor switch is designed for easy integration into various lighting setups. Follow these guidelines for optimal performance:
- Power Disconnection: Always turn off the main power supply at the circuit breaker before beginning installation.
- Mounting Location:
- Install the switch in a location where it will not be obstructed.
- It should preferably be installed vertically downward.
- Recommended installation height is between 2 to 3 meters, with a maximum height not exceeding 3.5 meters.
- Ensure the sensor faces the direction of anticipated human movement.
- Hole Preparation: If recessing the switch, prepare a hole with a diameter of approximately 20mm.
- Wiring: Refer to the wiring diagrams below for correct connection.
6. Wiring Diagrams
The sensor switch typically uses a 3-wire connection for input (Fire Line, Null Line) and output to the lighting fixture. Ensure all connections are secure and insulated.
6.1. Bulb or Energy Lamp Wiring
For traditional bulbs or energy-saving lamps, connect the brown wire to the Fire Line (L), the blue wire to the Null Line (N), and the yellow wire to the lighting fixture's live input. The lighting fixture's neutral input connects to the Null Line (N).
6.2. LED or Ring Tube Wiring
For LED lights or ring tubes, connect the brown wire to the Fire Line (L), the blue wire to the Null Line (N). The yellow wire connects to the driver or ballast of the LED/ring tube, which then powers the light. The neutral side of the driver/ballast connects to the Null Line (N).
6.3. Connection Examples
The switch can control a single luminaire or multiple lamps, provided the total load does not exceed 40W.
- Single Switch, Single Luminaire: Input (L) Fire Line and (N) Null Line connect to the switch. Output (L) Fire Line and (N) Null Line connect to the single lamp.
- One Switch, Many Lamps: Input (L) Fire Line and (N) Null Line connect to the switch. Output (L) Fire Line and (N) Null Line connect to multiple lamps in parallel.
7. Operation and Adjustments
Once installed and powered on, the sensor will automatically detect motion and control the connected lighting. If your unit features adjustment switches, you can customize its behavior:
7.1. Adjustable Illumination
This setting determines the ambient light level at which the sensor will activate. Use the switch to select:
- Deepdark (<2LUX): Activates only in very dark conditions.
- Lightdark (<25LUX): Activates in dim conditions.
- Allday: Activates regardless of ambient light level.
7.2. Adjustable Time Delay
This setting controls how long the light remains on after the last detected motion. Use the switch to select:
- 15Sec: Light stays on for approximately 15 seconds.
- 45Sec: Light stays on for approximately 45 seconds.
- 5Min: Light stays on for approximately 5 minutes.
8. Troubleshooting
- Light does not turn on:
- Check power connections and ensure the circuit breaker is on.
- Verify the load (lamp) is functioning correctly.
- Ensure the sensor is not obstructed.
- Check the illumination setting; if set to 'Deepdark' or 'Lightdark', it may not activate in brighter conditions.
- Light stays on constantly or turns on/off unexpectedly:
- Ensure the installation environment is free from wind, moving air, or heat sources (e.g., heaters, vents) that could cause false triggers.
- Avoid installing near cameras or other devices that emit infrared.
- Check the time delay setting; if set to '5Min', it will stay on for a longer period.
- Sensor not detecting motion effectively:
- Verify the installation height is within the recommended 2-3 meters range.
- Ensure the sensor is facing the primary area of movement.
- Clean the sensor lens if it appears dirty.
9. User Tips
- Check for Adjustments: Before installation, verify if your specific unit has the advertised illumination and time delay adjustment switches. Some units may have fixed settings.
- Optimal Placement: For best results, install the sensor in a location where it has a clear line of sight to the area you want to monitor, free from obstructions and environmental interferences like strong drafts or heat sources.
- Easy Connection: Users have reported the switch is easy to connect, making installation straightforward for those familiar with basic wiring.
- Test Thoroughly: After installation, test all settings (if applicable) and the detection range to ensure it meets your needs before finalizing the setup.
10. Warranty & Support
For detailed warranty information and customer support, please refer to the seller's policies or contact the point of purchase. A comprehensive user manual in PDF format may also be available for download from the product page or seller's website. You can find a PDF version of the item guide here.