1. Introduction
This manual provides essential information for the safe and efficient operation of your Sumry 3600W Hybrid Solar Inverter. This inverter is designed to provide reliable power for various applications, integrating solar power, utility grid, and battery storage. Please read this manual thoroughly before installation and use, and keep it for future reference.
Key Features:
- Pure sine wave solar inverter (On/Off Grid capability)
- Output power factor 1.0
- WIFI & GPRS available for iOS and Android monitoring (optional)
- Ability to run without a battery
- One-key restoration to factory settings
- Built-in Lithium battery automatic activation
- AC output voltage 120VAC
- Built-in 120A MPPT Solar charge controller with max 4200W input (for 3.6kW model)
- High PV input voltage range (60~500VDC)
- Built-in anti-dust kit for harsh environments
- Smart battery charge design to optimize battery life
- Dual output functionality
2. Safety Information
Always observe all safety precautions when installing, operating, or maintaining the inverter. Failure to follow these instructions may result in electric shock, fire, or severe injury.
General Safety Guidelines:
- Installation should be performed by qualified personnel.
- Ensure proper grounding of the PE protective conductor before any connections.
- Do not attempt to disassemble or repair the inverter yourself. Contact qualified service personnel.
- Keep the inverter away from flammable materials and moisture.
- Ensure adequate ventilation around the inverter to prevent overheating.
Intelligent Protection System:
The inverter is equipped with 15 intelligent protection modes to ensure safety and longevity of the unit and connected devices. These include:
- Overload Protection
- Overheating Protection
- High Back Low Protection
- Battery Protection
- Short Circuit Protection
- Supercurrent Protection
- Anti Reverse Protection
- Energy Fallout Protection

3. Setup and Installation
Unboxing and Overview:
Upon receiving your Sumry Hybrid Solar Inverter, carefully unbox it and inspect for any damage. Familiarize yourself with the unit's components and connection points.
Wiring Connections:
The inverter features clearly labeled connection terminals on its rear panel for AC input, main output, second output, communication, battery, and PV input.

Basic System Architecture:
The inverter integrates solar panels, the utility grid, a generator, and a lithium battery to power home appliances. It supports both on-grid and off-grid operations.

Circuit Breaker Installation:
Before installing and using the inverter, it is highly recommended to install four circuit breakers in the following positions:
- Between the battery pack and the inverter battery input.
- Between the solar panel and the photovoltaic input of the inverter.
- Between the power input of the grid and the inverter.
- Between the inverter output and the load.
These circuit breakers prevent misconnection or reverse connection and protect the inverter from short circuits, load short circuits, or overloads by cutting off the circuit.

Grounding:
Attention: Be sure to first ground the PE protective conductor.
Battery Compatibility:
The inverter is compatible with most types of batteries, including GEL, LI (Lithium), AGM, and FLD (Flooded). It also supports a 'USER' defined battery type for custom settings. The inverter can power loads directly from the PV array without a battery connected.

485 Communication Line:
The 485 communication line connects the RS485 port of the lithium battery to the COMM port of the inverter. This allows for exporting lithium battery data to the machine's display screen for easy monitoring. Note that a BMS protection board is typically inside the lithium battery, and the most common protection boards are from PACE. Therefore, the 485 communication cable must be purchased from PACE to ensure compatibility.

4. Operating Instructions
Frequency Setting:
The default frequency of the machine is 50Hz. If you require 60Hz operation, you can change this setting by adjusting item '09' in the inverter's menu to 60Hz.
Charging Modes:
The inverter offers four distinct charging modes to optimize energy input:
- Solar First: Prioritizes solar power for charging.
- Mains First: Prioritizes utility grid power for charging.
- Hybrid Charge: Uses a combination of solar and mains power.
- Only Solar: Exclusively uses solar power for charging.
Output Modes:
The inverter also provides four output modes to manage power delivery to your loads:
- Solar First: Prioritizes solar power for loads.
- Mains First: Prioritizes utility grid power for loads.
- Inverter First: Prioritizes inverter output (from battery or solar) for loads.
- Hybrid Output: Uses a combination of available power sources.

Monitoring via Smartess App:
The inverter can be monitored and controlled remotely using the Smartess App. WIFI and GPRS connectivity options are available for both iOS and Android devices.

Appliance Compatibility:
The 3600W Pure Sine Wave Inverter is suitable for powering a wide range of US appliances up to 3600W, providing clean and stable power to prolong their lifespan.

5. Maintenance
Cooling System:
The solar inverter features an intelligent cooling fan system. A built-in sensor chip intelligently adjusts the fan rotation speed based on the ambient temperature to maintain optimal operating conditions and prevent overheating.

Dust Protection:
A built-in anti-dust kit helps protect the internal components from dust accumulation, which is particularly beneficial in harsh environments. Regularly inspect the air vents for blockages and clean as necessary to ensure proper airflow.
Battery Care:
The smart battery charge design is implemented to optimize battery life. Ensure your batteries are compatible and correctly connected. Follow the battery manufacturer's guidelines for maintenance and charging cycles.
6. Troubleshooting
If you encounter any issues with your Sumry Hybrid Solar Inverter, please refer to the following general guidelines. For complex problems, contact customer support.
Common Issues and Solutions:
- No Power Output: Check all circuit breakers (battery, solar, grid, load) to ensure they are not tripped. Verify all wiring connections are secure.
- Overload Warning: Reduce the connected load. The inverter's intelligent protection system will activate to prevent damage.
- Overheating Warning: Ensure the inverter has adequate ventilation. Check for blocked air vents and clean them.
- Battery Not Charging: Verify solar panel connections and output. Check battery connections and health. Ensure the correct charging mode is selected.
- Communication Issues: Ensure the 485 communication cable is securely connected and is compatible with your lithium battery's BMS.
If problems persist, or for issues not listed here, please contact Sumry customer support for professional assistance.
7. Specifications
Below are the detailed technical specifications for the Sumry 3600W Hybrid Solar Inverter (Model: VICTOR NM-ECO-LV-3.6KW PLUS).

| Attribute | Specification |
|---|---|
| Brand Name | SUMRY |
| Model Number | 3600W 24V (VICTOR NM-ECO-LV-3.6KW PLUS) |
| Output Type | SINGLE |
| Size (L*W*H) | 500*415*180MM |
| Weight | 10KG |
| Output Frequency | 50/60HZ |
| Certification | CE |
| Battery Voltage | 24V |
| Maximum PV Input Power | 4200W |
| Rated Output Power | 3600W/3600VA |
| Maximum Solar Charging Current | 120A |
| Nominal DC Voltage/Maximum DC Voltage (PV) | 360/500VDC |
| MPPT Voltage Range | 60~450VDC |
| Maximum Input Current (PV) | 1/18A |
| Nominal Output Voltage (AC) | 120VAC (100/105/115V settable) |
| Output Voltage Range (AC) | 90-150VAC |
| Nominal Output Current (AC) | 30A |
| Maximum Conversion Efficiency (DC/AC) | 98% |
| Full Load | 3600W |
| Maximum AC Input Current | 40A |
| Output Wave Form | Pure sine wave |
| Operating Temperature | -15°C ~ 50°C |
| Operating Humidity | 5% to 95% Relative Humidity (Non-condensing) |
8. Warranty and Support
The Sumry 3600W Hybrid Solar Inverter comes with a 1-year warranty. For any technical assistance, troubleshooting, or warranty claims, please contact Sumry customer support. Our professional engineers are dedicated to providing expert answers and helping customers resolve any issues they may encounter.
9. User Tips
- Frequency Adjustment: If you are in a region that uses 60Hz power, remember to change the inverter's frequency setting from the default 50Hz to 60Hz via menu item '09'.
- Lithium Battery Communication: For optimal monitoring of lithium batteries, ensure you use the correct 485 communication cable, ideally from the same brand as your battery's BMS (e.g., PACE).
- Appliance Load Management: While the inverter supports up to 3600W, distribute your loads efficiently to avoid frequent overloads and ensure stable operation.
- Ventilation is Key: Always ensure the inverter has clear space around its cooling fans to prevent overheating, especially during high load operation or in warm climates.