1. Introduction
This manual provides essential information for the safe and effective installation, operation, and maintenance of your Sea YF-G1 Water Flow Sensor. Please read this manual thoroughly before using the device and keep it for future reference.
2. Product Overview
2.1 Features
- Suitable for petrochemical industry, community flow control, water plants, and farmland garden irrigation.
- High sensitivity, waterproof, heat-resistant, pressure-resistant, and cold-resistant design.
- Simple structure for easy installation and operation.
- Constructed from high-quality plastic for strong corrosion resistance, durability, light weight, and good insulation.
- Versatile for use in central air conditioning systems and swimming pool flow metering.
2.2 Components
The Sea YF-G1 Water Flow Sensor consists of a main plastic body with G1 inch male threaded inlet and outlet ports, an internal Hall effect sensor, and a 3-wire electrical connector.


3. Setup
3.1 Mechanical Installation
- Ensure the water supply is turned off and the system is depressurized before installation.
- Identify the desired installation point in your piping system. The sensor features G1 inch male threads for connection.
- Observe the flow direction arrow located on the bottom of the sensor body. Install the sensor so that the water flow matches this arrow.
- Apply appropriate thread sealant (e.g., PTFE tape) to the sensor threads.
- Carefully screw the sensor into the pipeline connections. Do not overtighten to avoid damaging the plastic body.
- Ensure all connections are watertight before proceeding.

3.2 Electrical Connection
The sensor operates on a DC5-24V power supply and has a 3-wire connector. Connect the wires as follows:
- Red Wire: Connect to DC Power Supply Positive (VCC, +5V to +24V)
- Black Wire: Connect to Ground (GND)
- Yellow Wire: Connect to Signal Output (Pulse Output)
Ensure all electrical connections are secure and insulated to prevent short circuits or water ingress.
4. Operating Instructions
The Sea YF-G1 water flow sensor generates a series of electrical pulses, the frequency of which is directly proportional to the rate of water flow. The pulse characteristic is given as F=1xQ, where F is the pulse frequency and Q is the flow rate. To measure flow, you will need an external microcontroller or pulse counter to read these signals.
- Once installed and wired, turn on the water supply and the DC power to the sensor.
- The sensor will begin outputting pulses on the yellow signal wire as water flows through it.
- Connect the yellow signal wire to a suitable input on your data acquisition system (e.g., a microcontroller's interrupt pin).
- Program your system to count the pulses over a specific time interval to determine the pulse frequency.
- Use the provided pulse characteristic (F=1xQ) to convert the measured frequency into a flow rate. Note: The '1' in the formula is a calibration factor; specific units for Q (e.g., L/min) should be determined through calibration or detailed specifications from the manufacturer if available.
5. Maintenance
- Regular Inspection: Periodically check the sensor for any signs of leaks, physical damage, or corrosion.
- Connection Check: Ensure all mechanical and electrical connections remain secure.
- Cleaning: If the sensor is exposed to water with high particulate matter, internal components may become fouled, affecting accuracy. If a decrease in accuracy is observed, the sensor may need to be removed and carefully flushed with clean water. Avoid using harsh chemicals or abrasive tools.
- Winterization: In freezing conditions, ensure the sensor and connected pipes are drained to prevent damage from ice expansion.
6. Troubleshooting
- No Pulse Output:
- Check if the DC power supply (5-24V) is correctly connected to the red and black wires.
- Verify that water is actually flowing through the sensor.
- Inspect the yellow signal wire connection to your reading device. - Inaccurate Readings:
- Ensure the sensor is installed in the correct flow direction (refer to the arrow on the sensor body).
- Check for any blockages or debris inside the sensor that might impede the internal rotor.
- Verify the calibration factor used in your calculation (F=1xQ). - Leaks at Connections:
- Turn off water supply and depressurize the system.
- Re-apply thread sealant and re-tighten connections. Do not overtighten.
7. Specifications
| Parameter | Value |
|---|---|
| Item Type | Flow Sensor |
| Material | Plastic |
| Model | YF-G1 |
| Interface Size | G1 inch male thread |
| Flow Range | 2-100 L/min |
| Working Voltage | DC5-24V |
| Pulse Characteristics | F=1xQ |
| Withstand Voltage Range | ≤2MPA |
For a downloadable version of these specifications and instructions, please refer to the official user manual PDF: Sea YF-G1 User Manual (PDF)
8. User Tips
No specific user tips were available from customer reviews or Q&A for this product.
9. Warranty & Support
For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.