NJTY T6005 T6010

Contents

NJTY T6005 / T6010 Analog Insulation Resistance Tester User Manual

Models: T6005 (500V), T6010 (1000V)

1. Introduction and Overview

This manual provides essential instructions and safety guidelines for the safe operation and maintenance of your NJTY T6005 or T6010 Analog Insulation Resistance Tester. Please read these instructions thoroughly before using the instrument.

The T60 series pointer-type insulation testers, including models T6005 and T6010, are designed for measuring the insulation resistance of various electrical equipment and insulating materials. These devices are compact, portable, and offer high accuracy and reliability, making them ideal for routine maintenance, testing, and verification of electrical equipment such as transformers, motors, cables, switches, and appliances.

  • The T6005 model supports 500V insulation testing.
  • The T6010 model supports 1000V insulation testing.
NJTY T6010 Analog Insulation Resistance Tester front view with display and controls.
Front view of the T6010 model, showing the analog display, test button, and input terminals.

2. Safety Information

The symbol "▲" on the instrument indicates that users must follow the relevant safety instructions in this manual. Pay special attention to the safety rules and warning notes to avoid electric shock and damage to the instrument.

General Safety Rules:

  1. Read this manual carefully before use.
  2. Do not use the instrument if the battery cover is not securely closed, as this poses an electric shock hazard.
  3. Before use, ensure the test leads' insulation is intact and undamaged.
  4. To avoid damaging the instrument, perform insulation measurements only on disconnected circuits.
  5. Do not press the "Test Button" when measuring voltage.
  6. To avoid electric shock, do not touch the test leads or the circuit being tested during measurement.
  7. Avoid touching the tested circuit immediately after testing, as residual charge may cause electric shock.

Electrical Symbols:

  • ACV: AC voltage
  • DCV: DC voltage
  • ▲: Warning
  • ▲: High Voltage Hazard
  • Auto Discharge: Automatic discharge function
  • Withstand voltage test: Indicates capability for withstand voltage testing
  • Low resistance alarm: Indicates low resistance alarm feature

3. Product Features

The T60 series insulation testers offer a range of features designed for efficient and accurate measurements:

  • Wide Measurement Range: Capable of measuring up to 2000 MΩ.
  • Voltage Measurement: T6005 and T6010 can measure AC voltage below 500V. The T6015 (not covered in this manual) can measure AC and DC voltage below 500V.
  • Low Resistance Buzzer Alarm: An audible alarm sounds when measured resistance falls below a preset value, alerting the user.
  • Working Indicators:
    • Battery undervoltage status (red light).
    • Automatic shutdown after 15 minutes (single green light).
    • Continuous working indication (double green lights).
  • Rechargeable Battery: Uses a 3.7V 18650 rechargeable battery with a convenient Type-C charging interface.
  • Wider Dial Design: Provides a broader indication range for more accurate readings.
  • Automatic Discharge Function: Automatically discharges residual charge after shutdown to prevent electric shock.
  • Strong Output Load Capacity: Features a large output short-circuit current.
  • Transistor Withstand Voltage Measurement: Directly reads the withstand voltage value (load voltage) of the material under test.
T6010 Insulation Resistance Tester magnetically attached to an electrical cabinet.
The T6010 tester demonstrating its magnetic back, attached to a metal electrical cabinet.
Back view of the insulation resistance tester showing battery compartment and strong magnet.
Detailed view of the tester's back, highlighting the strong magnet for attachment and the compartment for the 18650 lithium battery.

4. Panel Diagram and Components

Familiarize yourself with the layout of your insulation resistance tester:

T6005 Insulation Resistance Tester Configuration Diagram showing included accessories.
Configuration Diagram for T6005, illustrating the main unit and accessories.

Key Components (Refer to diagram for T6005/T6010):

  1. Charging indicator light
  2. Work indicator light
  3. Gear position rotary switch (Note: T6005/T6010 models may not have this; primarily for T6015)
  4. EARTH input terminal (connects to the ground terminal of the circuit under test)
  5. LINE input terminal (connects to the circuit under test)
  6. Test button
  7. Pointer zero adjustment
  8. Insulation meter reading dial

5. Setup

5.1. Mechanical Zero Adjustment

Before performing any insulation measurement, check the pointer's position. Ensure it aligns with the "∞" (infinity/zero position on the left) mark on the insulation meter scale. If it does not, use a small screwdriver to rotate the "pointer zero adjustment" screw on the meter to correct the zero position.

5.2. Test Lead Connection

Insert the red test lead into the 'L' (LINE) port and the black test lead into the 'E' (EARTH) port of the meter.

5.3. Charging and Battery Replacement

The instrument uses a 3.7V 18650 rechargeable lithium battery. It features a Type-C charging interface.

  • Charging: Connect a 5V USB power supply (e.g., power bank, car charger) to the Type-C port. The charging indicator light will be red during charging and turn green when fully charged. Do not perform tests while charging.
  • Battery Status: When the instrument is working normally, a green work indicator light signifies sufficient battery. A red work indicator light indicates low battery (undervoltage), prompting you to charge or replace the battery.
  • Battery Replacement: To prevent electric shock, always remove test leads from the instrument before opening the battery compartment. If the battery fails, replace it with a battery of the same specification.

6. Operating Instructions

6.1. Insulation Resistance Measurement

  1. Power On/Off:
    • Press and hold the "test button" for 1 second to turn on the meter. The green "working" indicator light on the upper right corner of the dial will illuminate.
    • The meter will automatically shut down after 15 minutes of normal operation.
    • For continuous working state, press the "test button" three times within 5 seconds after powering on. Both green indicators will light up, and the automatic shutdown function will be canceled.
    • To manually shut down, press and hold the "test button" for 1 second after 5 seconds of powering on.
    • In undervoltage state, the working indicator light is red, and it will automatically shut down after 15 minutes.
  2. Measurement: After starting the insulation measurement, touch the test leads to the insulator being measured and read the value from the pointer scale.
Insulation resistance testing of an electric motor using the T6010 tester.
The T6010 tester connected to an electric motor for insulation resistance measurement.

6.2. AC and DC Voltage Measurement

  1. Ensure no insulation measurement is active (working indicator light is off).
  2. For T6015 (if applicable), switch to the corresponding voltage range. T6005 and T6010 can measure directly.
  3. Touch the test leads to the two ends of the voltage to be measured.
  4. Read the measured value from the pointer scale.
  5. Note: When measuring DC voltage with T6015, insert the red test lead into "+" and the black test lead into "-".

6.3. Transistor Withstand Voltage Measurement

  1. Connect the transistor to be tested to the meter, observing polarity.
  2. Press the test button to directly read the BV(V) voltage scale. This value represents the withstand voltage of the transistor (the DC load voltage value L(V) at both ends of the material being tested).
  3. The maximum withstand voltage measurement for T6010 is 1000V. The maximum withstand voltage measurement for T6005 is 500V.

7. Specifications

Parameter T6015 T6005 T6010
Power Supply 1 x 3.7V 18650 rechargeable lithium battery
Dimensions 161 × 96 × 45 mm
Weight Approximately 534 g (including accessories)
Operating Temperature 0°C - 40°C, Relative Humidity <75% (non-condensing)
Storage Temperature -10°C - 50°C, Relative Humidity <85%
Calibration Temperature 23°C ±5°C, Relative Humidity <70%
Rated Test Voltage 1000V, 500V, 100V 500V 1000V
Low-Resistance Alarm <2MΩ, <1MΩ, <200kΩ <2MΩ <2MΩ
Transistor Withstand Voltage Test 1000V, 500V, 100V 500V 1000V
Output Short-Circuit Current Max 0.75 mA Max 0.65 mA Max 1.3 mA
Measurement Range 0-1000MΩ 0-2000MΩ 0-2000MΩ
Measurement Accuracy 1M-2000MΩ ±10% 1M-1000MΩ ±10% 1M-2000MΩ ±10%
Voltage Measurement Range DCV500V, 50V; ACV500V (50HZ) ACV500V (50HZ) ACV500V (50HZ)
Insulation Test Output Voltage 90%-120% of Rated Voltage
Discharge Resistance 10MΩ
Voltage Measurement Error ±5% (Full Scale)
Battery Detection 3.3V Low Voltage Indication
Insulation (Movement circuit and case) >50MΩ

8. Maintenance

This instrument is a precision electronic device and requires careful maintenance to ensure longevity and accuracy.

  1. Long-Term Storage: If the instrument will not be used for an extended period, recharge the battery every two months to maintain its health.
  2. Storage Environment: Store the instrument in a dry place, away from humid environments.
  3. Physical Handling: Avoid strong vibrations or impacts, as these can damage the meter head or internal circuitry.
  4. Internal Circuitry: Do not attempt to modify the internal circuitry. If a malfunction occurs, contact customer support for assistance.

9. Troubleshooting

This section provides general guidance for common issues. For complex problems, please refer to the support section.

  • No Power/Display: Ensure the battery is charged. Check the battery compartment for proper battery insertion.
  • Inaccurate Readings: Perform mechanical zero adjustment as described in Section 5.1. Ensure test leads are properly connected and undamaged.
  • Device Text in Chinese: Some units may have Chinese text on the device. Refer to this manual for English instructions and diagrams.

10. Package Contents

Upon unpacking, verify that all the following items are included:

  • T60 Series Insulation Resistance Tester x 1
  • Portable Tool Bag x 1
  • Insulation Resistance Tester Test Leads x 1 pair
  • User Manual x 1 (This document, and a PDF version is available here)
  • 18650 Rechargeable Lithium Battery x 1
  • USB Charging Cable x 1 (Type-C)
T6005 Insulation Resistance Tester Configuration Diagram showing included accessories.
Visual representation of the T6005 tester and its included accessories.

11. User Tips

  • Many users find this product very useful and effective for its intended purpose.
  • The device is generally reported to work well and as described.
  • Be aware that some units may have text on the device itself in Chinese. Refer to the English user manual for all operational instructions.

12. Frequently Asked Questions (FAQ)

Q: Does the device only come in Chinese?
A: While the text on the physical device itself might be in Chinese, this user manual provides comprehensive instructions in English. Please refer to this manual for all operational guidance.

13. Warranty and Support

For warranty information, technical support, or assistance with any malfunctions, please contact your retailer or the manufacturer's customer service. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.