The Hi-Link UR(A)B_LD-30WR3 series DC-DC Isolated Power Converter Modules offer a robust solution for various power conversion needs. These modules provide 30W output power with a 4:1 wide voltage input range and achieve an efficiency of up to 91%. Key features include a standard isolation voltage of 1500VDC and an allowable operating temperature range of -40°C to +85°C. They are equipped with essential protection functions such as input undervoltage, output overvoltage, overcurrent, and short-circuit protection. The bare units comply with CISPR32/EN55032 CLASS A standards, making them suitable for a wide array of applications including medical devices, industrial control systems, power equipment, instrumentation, communication systems, and railway applications.

Video: Overview of Hi-Link DC-DC Isolated Power Converter modules, showcasing various models and their compact design.

2. Safety Instructions

  • Ensure the input voltage is within the specified range (9-36Vdc) to prevent permanent damage to the product.
  • Do not exceed the maximum capacitive load specified for your product model, as this may prevent the module from starting normally.
  • When using capacitive loads, ensure a minimum load of 3% is maintained to prevent abnormal module output.
  • Observe proper polarity when connecting input and output terminals.
  • The module is designed for natural cooling. Ensure adequate airflow around the module during operation.
  • The module provides 1500Vdc isolation. However, always handle with care and ensure proper grounding in your application.

3. Product Features

  • Ultra wide input voltage range (4:1), output 30W
  • High conversion efficiency: 91% (Typical)
  • High isolation voltage: 1500Vdc
  • Ultra low standby power consumption: 0.036W (Typical)
  • Ultra fast startup time: 1mS (Typical)
  • Wide operating temperature range: -40°C to +85°C
  • Comprehensive output protection: short circuit protection, over current protection, over voltage protection
  • Durable metal case, ensuring low output ripple
  • International standard pin configuration for PCB board in-line installation
  • Sealed with high-quality environmental protection waterproof and thermal conductive glue, providing moisture-proof and vibration-proof properties, meeting IP65 requirements.
  • High reliability and long-life design for continuous operation.
Hi-Link UR(A)B24_LD-30WR3 series product overview highlighting isolation voltage, conversion efficiency, low power consumption, and low output ripple.

Figure 1: Key features of the UR(A)B24_LD-30WR3 series.

4. Specifications

4.1 General Specifications

Item Specification Unit
Voltage rangeLow voltage non-USB (below 75V DC, below 50V AC)
Power SourceDC
Inbox adaptorNo
High-concerned chemicalNone
Efficiency91%
Isolation1500Vdc
Low power consumption0.036W
Start time1ms
Work temp.-40~85°C
Input range9-36Vdc
Size50.8*25.4*11.8mm
Insulation voltage1500VDC
Insulation resistance1000 (Input-output, 500VDC)MΩ
Isolation capacitor1000 (Input-output, 100KHz/0.1V)pF
Storage temperature-40 ~ +125°C
Max operating case+100
Storage humidity5 ~ 95 (no condensation)%RH
Pin SolderingSolder joint distance from shell 1.5mm, 10 seconds°C
On-off levelPWM model, 250KHz
Vibration10-55Hz, 10G, 30 Min. along X, Y and Z
Shell materialAluminum shell
Minimum time between failures2X105 (MIL-HDBK-217F@25°C)Hrs

4.2 Input Characteristics

Item Working Conditions Min. Typ. Max. Unit
Rated input voltage24Vdc
Input voltage range936Vdc
Max input current≤3.4A
Reflected ripple currentDC24V rated input voltage series40mA
Impulse voltage (Isec.max)24VDC nominal input series-0.750
48VDC nominal input series-0.7100
110VDC nominal input series-0.7180
Starting voltage24VDC nominal input series9VDC
48VDC nominal input series18
110VDC nominal input series40
Input undervoltage protection24VDC nominal input series5.56.5
48VDC nominal input series1215.5
110VDC nominal input series3034
Start delay timeNominal input voltage and constant resistance load1mS
Input filter typePI version
Hot plugNot available
Remote control (Ctrl)Module openCtrl floating or connected to TTL high level
Module closeCtrl is connected to GND or low level
Input current at shutdown01mA

4.3 Output Characteristics

Project Working and test conditions +Vo1 -Vo2
Min. Typ. Max. Min. Typ. Max.
Output loadLoad percentage0%100%0%100%
Output voltage accuracy±1.0%±2.0%±2.0%±3.0%
Linear adjustment rateInput voltage range±0.2%±0.5%±1.5%±2%
Load regulation20% ~ 100% rated load±0.5%±1%±4.0%±5.0%

4.4 Product Mode List

The UR(A)B_LD-30WR3 series offers various models with different output voltages and currents. Below is a summary of typical models. For a complete list or specific requirements, please refer to the full PDF manual or contact Hi-Link directly.

Table showing various UR(A)B24_LD-30WR3 product models with input voltage range, output voltage/current, ripple and noise, maximum capacitive load, and efficiency.

Figure 2: UR(A)B24_LD-30W Mode List.

4.5 Package Size and Pin Function Diagram

Diagram showing the dimensions and pinout of the Hi-Link 30W DC-DC converter module.

Figure 3: Package Size and Pin Function Diagram.

Pin Single Output (S) Dual Output (D)
1+Vin (Input+)+Vin (Input+)
2-Vin (Input-)-Vin (Input-)
3CTRL (Remote control)CTRL (Remote control)
4Trim (Voltage regulator)-Vo2 (Output-2)
5-Vo (Output-)COM (Common ground)
6+Vo (Output+)+Vo1 (Output+1)

Note: If the definition of each pin of the power module is inconsistent with the selection manual, the label on the physical label shall prevail.

5. Setup and Wiring

All DC/DC converters in this series are tested according to the recommended test circuit shown below before leaving the factory. This circuit provides a baseline for proper operation.

Recommended test circuit diagram for Hi-Link DC-DC converter modules, showing input and output capacitor placement.

Figure 4: Recommended Test Circuit. General recommended capacitance: D1: 47-100 μF; C2, C3: 10-22μF.

To further reduce input and output ripple, you can increase the input and output external capacitors D1, C2, C3 or choose a capacitor with a small series equivalent impedance. However, the capacitance value cannot be greater than the maximum capacitive load of the product. For general ripple & noise requirements, use only C2 and C5 for the periphery. For strict ripple & noise requirements, the circuit shown below is recommended.

EMC solution circuit diagrams for single and dual output modules, showing recommended filter components like LDM3, LDM4, LDM5, and capacitors C2, C3, C4, C5, C6, C7.

Figure 5: EMC Solutions - Recommended Circuits (Positive and negative dual output products on left, Single output products on right).

Note: C2, C3, C5, C6 use high-frequency low-resistance electrolytic capacitors, and the total capacity cannot exceed the maximum capacitive load marked in the manual, otherwise the module will not be able to start normally. LDM5 is only used for dual output products.

5.3 Trim and Calculation of Trim Resistance

The Trim pin allows for fine-tuning of the output voltage. The application circuit and calculation formulas for Trim resistance are provided below. The dotted box indicates components inside the product.

Vout(V) R1(KΩ) R2(KΩ) R3(KΩ) Vref(V)
3.33018.26184.51.25
545.314.77884.51.25
93011.44184.52.5
125614.57184.52.5
155611.21884.52.5
2484.59.79184.52.5

5.4 Ripple & Noise Test Method

To measure ripple noise, connect a 12# twisted pair cable. Set the oscilloscope bandwidth to 20MHz and the probe bandwidth to 100M. A 0.1uF polypropylene capacitor and a 47uF high-frequency low-resistance electrolytic capacitor should be connected in parallel on the probe end. Use the Sample sampling mode on the oscilloscope.

For the output ripple noise test, connect the power input terminal to the input power supply and the power output to the electronic load through the fixture board. Use a 30cm ± 2cm sampling line to directly sample from the power output port. The power line should be selected with an insulation sheath of the corresponding wire diameter according to the magnitude of the output current.

6. Operation

The Hi-Link DC-DC converter module is designed for straightforward operation once properly installed. Ensure all connections are secure and correct before applying power.

  • Power On: Apply the specified DC input voltage (9-36Vdc) to the +Vin and -Vin terminals. The module will start up within 1ms (typical).
  • Output: The module provides a stable, isolated DC output at the +Vo and -Vo (or +Vo1, -Vo2, COM for dual output) terminals. Refer to the product mode list for specific output voltage and current ratings.
  • Remote Control (CTRL Pin):
    • To open the module (enable output), leave the CTRL pin floating or connect it to a TTL high level (3.5-12VDC).
    • To close the module (disable output), connect the CTRL pin to GND or a low level (0-1.2VDC).
  • Output Voltage Adjustment (Trim Pin - Single Output Models): For models with a Trim pin, the output voltage can be adjusted using an external resistor network as detailed in Section 5.3.

7. Maintenance

The Hi-Link DC-DC converter modules are designed for high reliability and long life, requiring minimal maintenance.

  • Cooling: The module uses natural cooling. Ensure that the operating environment allows for adequate heat dissipation and that the ambient temperature remains within the specified range of -40°C to +85°C.
  • Storage: When not in use, store the module in an environment with a temperature range of -40°C to +125°C and relative humidity between 5% and 95% (non-condensing).
  • Cleaning: Keep the module free from dust and debris to ensure optimal performance and heat dissipation. Use a soft, dry cloth for cleaning.
  • Inspection: Periodically inspect connections for any signs of wear or damage.

8. Troubleshooting

  • Module does not start:
    • Check if the input voltage is within the 9-36Vdc range.
    • Verify that the connected capacitive load does not exceed the maximum specified for your model. Exceeding this value will prevent normal startup.
    • Ensure the CTRL pin is either floating or connected to a TTL high level (3.5-12VDC) to enable the module.
  • Unstable or abnormal output:
    • If using capacitive loads, ensure a minimum load of 3% is applied to prevent abnormal output.
    • Check for proper connections and ensure no short circuits or overcurrent conditions are present. The module has built-in protection, but continuous stress can affect performance.
    • Review the EMC solution circuits (Section 5.2) to ensure proper filtering components are used to reduce ripple and noise.
  • Module overheating:
    • Ensure adequate ventilation and airflow around the module.
    • Verify that the ambient operating temperature is within the -40°C to +85°C range.
    • Confirm that the output load does not exceed the module's rated power (30W).
  • No output:
    • Check for input undervoltage, output overvoltage, overcurrent, or short-circuit protection activation. Remove the fault condition and reapply power.
    • Ensure the CTRL pin is not connected to GND or a low level.

9. User Tips

  • Pre-connection Check: Before connecting the module, double-check all wiring against the pin function diagram (Figure 3) to ensure correct polarity and pin assignment.
  • Filtering for Sensitive Applications: For applications sensitive to ripple and noise, it is highly recommended to implement the full EMC solution circuits (Figure 5) with the specified components to achieve optimal performance.
  • Load Management: Always ensure your load requirements are within the module's specifications to prevent overstress and ensure longevity. Pay particular attention to the maximum capacitive load.

10. Warranty and Support

Hi-Link modules are designed for high reliability and long operational life. For technical support, inquiries, or further information, please contact Shenzhen Hi-Link Electronic Co., Ltd using the details below:

  • Address: Room 301, Building 1, 1970 Science & Technology Park, Minzhi Community, Minzhi Street, Longhua District, Shenzhen
  • Website: www.hlktech.com
  • Email: sales@hlktech.com
  • Tel: 0755-23152658

A detailed PDF version of this manual is available for download from the manufacturer's website or via the provided link: User manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.