RIDEN RD6018P

Contents

RD6018P 60V 18A Digital Display DC Power Supply Instruction Manual

Model: RD6018P

Brand: RIDEN

1. Introduction

Thank you for purchasing the constant voltage constant current DC power supply produced by Hangzhou Ruideng Technology Co., Ltd. This manual provides detailed instructions to help you understand the full functionality of your RD6018P power supply, ensure proper usage, and avoid misuse. Please read this instruction carefully before using it and keep it for future reference.

Note: This instruction corresponds to various RD series models (RD6006, RD6012, RD6018, RD6024, RD6030/RD6030-Max, RD6006P, RD6012P/RD6012P-Max, RD6018/RD6018-Max) with different firmware versions. Page layouts and operations may vary slightly. We recommend downloading the latest firmware for the best experience. This manual is specifically tailored for RD series assembled set users.

2. Safety Information

Always observe the following safety precautions to prevent injury or damage to the device:

  • Ensure proper ventilation around the power supply during operation.
  • Do not expose the device to moisture or extreme temperatures.
  • Use appropriate input voltage as specified in the technical parameters.
  • Avoid short-circuiting the output terminals.
  • Do not attempt to disassemble or modify the device unless explicitly instructed.
  • When performing calibration, ensure it is done by a professional electronic person with a high-precision multimeter. Incorrect operation can exceed hardware limits and cause damage, which is not covered by warranty.
  • When charging batteries, ensure you know the battery parameters well. Using the wrong charging method can pose a risk of fire and explosion. It is strongly recommended to use the original charger for batteries.

3. Package Contents

Verify that all items are present in your package:

  • RD power supply (x1)
  • Output cable (x1)
  • Input AC Power Cord (x1) - AC cord type may vary
  • Communication cable (x1) - inside cable bag
  • External Temperature Sensor (x1)
  • Backup Fuse (x1)

4. Technical Parameters

The following table outlines the technical specifications for the RD6018P and related models:

ParameterRD6006RD6012RD6018RD6024RD6030/RD6030-MaxRD6006PRD6012P/RD6012P-MaxRD6018P/RD6018P-Max
Input voltage rangeAC100-120V/200-240V
Display digit4-digit5-digit
Output voltage range0-60V
Output current range0-6A0-12A0-18A0-24A0-30A0-6A0-12A0-18A
Output power range0-360W0-720W(AC220V)0-1080W (AC110V)0-80W(AC220V)0-1440W (AC110V)0-1140W(AC220V)0-1800W (AC110V)0-1440W0-360W0-720W0-1080W
Output voltage resolution10mV1mV
Output voltage accuracy0.3%+30mV0.05%+4mV
Output current resolution1mA10mA0.1mA0.1mA/1mA1mA
Output current accuracy0.5%+5mA0.5%+50mA0.1%+0.6mA0.1%+0.6mA0.1%+6mA
Battery voltage resolution0.01V
Battery voltage accuracy0.5%+0.03V
Default battery charging cutoff current10mA100mA10mA
Output ripple typical (VPP)100mV250mV@6A100mV@12A, 150mV@24A, 50mV@15A, 90mV@30A20mV
Working temperature range-10°C ~ 40°C
External sensor Temperature detection range-10°C ~ 100°C / 0°F ~ 200°F
External sensor Temperature detection error±3°C/±6°F
Constant voltage mode response time2ms (0.1A-5A load)200µS (0.5A-18A)
Constant voltage mode load regulation±(0.1%+2mV)±(0.1%+0.2mV)
Constant current mode load regulation0.1%+3mA0.1%+3mA
Capacity measurement range0-9999.99Ah
Energy measurement range0-9999.99Wh
Capacity and energy statistical error±2%
Cooling fan start conditionOutput voltage >40V or Output current >4A or System temperature >45°C (for 4-digit models); Output current >8A or System temperature >45°C (for 5-digit models); Output current >4A or System temperature >50°C (for P-series models); Output current >6A or System temperature >45°C (for Max models)
Cooling fan shut down condition when workingOutput voltage <40V and Output current <3.9A and System temperature <40°C (for 4-digit models); Output current <7.9A and System temperature <40°C (for 5-digit models); Output current <3.9A and System temperature <45°C (for P-series models); Output current <5.9A and System temperature <40°C (for Max models)
Over temperature protectionSystem temperature >80°C
Screen brightness setting0-5 (6 levels)
Screen2.4 inch color HD display (3.2 inch screen for RD-Max version)
Input output fuse1808 fast blow fuse (for 4-digit models); 1032 fast blow fuse (for 5-digit models)
Fuse current10A20A25A30A40A10A20A25A
Package weight (about)3 kg3.4kg3.7kg4 kg3.2kg3 kg3.4kg3.7kg
Product dimension (about)17.3*9.2*33.6cm
USB communicationYES
WiFi communicationNO (Only RD6012P-W supports WiFi)

Ripple measurement method: Noise and ripple are measured at X1 range, AC coupling, 20 MHz of bandwidth on your oscilloscope with a 0.1uF parallel capacitor at the output terminals, pure resistor as load.

5. Panel Instruction

5.1 Front Panel

Front panel of the RD6018P DC Power Supply with labels for controls and display elements.
Figure 1: Front panel of the RD6018P DC Power Supply, showing the digital display, keypad, rotary encoder, and various input/output terminals.
LabelDescription
APower button
BSHIFT Second function button
CQuick storage button
DCurrent/Over current protection setting
EVoltage/Over voltage protection setting
FMicro USB port (USB-C port for Max version)
GPower supply output negative terminal / Battery charging negative terminal
HBattery charging positive terminal (Dedicated terminal for battery charging)
IPower supply output positive terminal
JOutput switch
KEnter/Confirm button
LEncoder potentiometer/Cancel button
MDirection button
NKeypad
OScreen

5.2 Back Panel

Back panel of the RD6018P DC Power Supply, showing input power socket, external temperature sensor socket, rocker switch, and heat dissipation holes.
Figure 2: Back panel of the RD6018P DC Power Supply.
LabelDescription
PInput power socket
QRocker switch
RExternal temperature sensor socket
SHeat dissipation holes

6. Setup

The RD6018P is a module that requires assembly with a power supply unit (PSU) and a case to form a complete power supply. These accessories are typically purchased separately.

Diagram showing the RD6018P module, a 1200W PSU, and an S800 case, illustrating how they combine to form a complete power supply.
Figure 3: Components required to assemble a complete power supply, including the RD6018P module, a 1200W PSU, and an S800 case.

To assemble your power supply:

  1. Mount the RD6018P module: Secure the RD6018P module into the designated slot in the S800 case.
  2. Install the PSU: Place the 1200W PSU (or compatible power supply) inside the case and secure it.
  3. Connect Wiring: Connect the output of the PSU to the input terminals of the RD6018P module. Ensure all connections are secure and correctly polarized.
  4. Connect AC Power: Use the provided AC power cord to connect the PSU to a suitable AC power outlet.
  5. Attach External Temperature Sensor: If desired, connect the external temperature sensor to its dedicated socket on the back panel.
  6. Insert WiFi Board (if applicable): If using a WiFi-enabled model (e.g., RD6018P-W), insert the WiFi board into the correct position.

After power-on, the device will display a boot image before entering the main operating page.

7. Operation

7.1 Main Page Overview

The main page displays critical information about the power supply's status and settings. It typically shows actual output voltage, actual output current, output power, input voltage, preset voltage/current, protection status, battery charging indication, communication interface status, and date/time.

Main display page of the RD6018P showing voltage, current, power, and various status indicators.
Figure 4: Main operating page displaying real-time output and settings.

You can switch between Traditional Style, Detail Style, and Curve Style displays by pressing the appropriate button. Note that the display style is not automatically saved; you must set your preferred default Home Style in the System Settings.

7.2 Output Voltage and Current Setting

To set the output current value, press the I-SET button. Use the encoder potentiometer to adjust the value. The value will be applied directly. You cannot set a value exceeding the device's limits. Use the direction buttons to move the cursor. Pressing the encoder potentiometer again will save the setting to the current data group (MB).

To set the output voltage value, press the V-SET button. The operation is similar to setting the output current.

If you enter a value that exceeds the limit, the device will display a "Set Error" message.

7.3 Over Current/Voltage Protection (OCP/OVP) Setting

Press SHIFT + I-SET or SHIFT + V-SET to set the over current protection (OCP) or over voltage protection (OVP) values. The operation is similar to setting output current/voltage. For OCP to function as an auto cut-off, your OCP value must be lower than the current setting value.

The device indicates its operating mode:

  • CV: Constant Voltage mode
  • CC: Constant Current mode
  • Protection Status Indicator: Appears when the device is working normally.
  • OCP: Over Current Protection, output cut off automatically if actual current exceeds OCP value.
  • OVP: Over Voltage Protection, output cut off automatically if actual voltage exceeds OVP value.
  • OTP: Over Temperature Protection, output cut off automatically if system temperature exceeds 80°C.
Input Over-Voltage Protection warning display on the RD6018P.
Figure 5: Over-Voltage Protection warning displayed when input voltage exceeds 72V.

7.4 Data Group Quick Storage and Call Out

Press MEM + keypad button (1-9) to store the current output voltage, OCP, OVP, and over current protection values into the corresponding data group. Press ENTER to confirm. To quickly call out saved data, press SHIFT + keypad button (1-9).

7.5 Keypad Lock and Unlock

Press SHIFT + LOCK to lock or unlock the keypad. The keypad will automatically lock when communication starts. During this time, only the power button can be used. The keypad will automatically unlock after 3 seconds if the connection is disconnected.

7.6 System Settings

Press SHIFT + 0 to enter the system setting menu. Use the direction buttons or encoder potentiometer to navigate and select options. Settings are automatically saved when returning from the menu page.

Key settings include:

  • System Language: Default is English. Options include Simplified Chinese, French, German, and Russian.
  • Take OK: (Default ON) When ON, calling a data group prompts for confirmation. When OFF, settings are applied directly.
  • Take Out: (Default OFF) When ON, calling a data group will automatically turn on the output.
  • Boot Power: (Default OFF) When ON, the output will automatically turn on after booting.
  • Boot Logo: (Default ON) When ON, the boot logo is displayed. When OFF, the device directly enters the main interface.
  • Buzzer: (Default ON) Controls audible feedback for button presses.
  • Backlight: Adjustable from level 0-5 (default 4).
  • Update Rate: Sets the refresh rate for real output voltage and current (Low/Mid/High).
  • Max Power: Sets the maximum output power (default 740W). The device will automatically decrease the output current if (setting voltage * setting current) exceeds this value.
  • Temperature Unit: Switch between °C and °F.
  • Battery Charger Sub-menu:
    • Cut-Off Current: Default 10mA. Output is cut off if real output current is lower than this value.
    • Cut-Off Temp: Default 60°C. Output is cut off if external temperature sensor detects over 60°C.
  • Communication Sub-menu: Set interface to USB, WIFI, or RS485.
    • USB: Micro USB port.
    • WIFI: Requires a WiFi board (only for RD6018P-W).
    • RS485: Requires an RS485 module.
  • Date and Time Sub-Menu: Set date and time (Year 2000-2100). Can be synchronized via PC software or phone APP.
  • Main Page Display Style Setting (Layout Sub-menu):
    • Digits Style: Normal/7-Seg V1/7-Seg V2.
    • Home Style: 0 (traditional), 1 (detail), or 2 (curve).
    • Custom Colors: Set display colors for output voltage, current, power, etc. (15 colors available).

7.7 Battery Charging Function

Connect the green terminal to the positive electrode and the black terminal to the negative electrode of the battery. The battery charging indicator will turn red when connected, then green when charging starts. The output will automatically cut off if the actual output current is lower than the set cut-off current (default 10mA) or if the external temperature sensor detects a temperature above the set cut-off temperature.

Important: The battery charging function of this device is for temporary use only. It is crucial to understand your battery's parameters. Improper charging can lead to fire or explosion. Always use the original charger for long-term battery charging.

7.8 Mobile APP Instruction (Android & iOS)

The RD6018P-W model supports WiFi connection for mobile app control. A WiFi board is required. The Android app supports Android 5.0-10.0. The iOS app supports iOS 10.0-14.3 on iPhone 6 and above.

Mobile APP interface for the RD6018P, showing voltage and current graphs, settings, and controls.
Figure 6: Mobile APP interface for monitoring and controlling the power supply.

APP Download:

  • Android: Download the RD60XX APP zip-file from this link. Install from your file manager.
  • iOS: Search for "Ruideng tech" in the Apple App Store.

Installation & Connection:

  1. Insert the WiFi board into the RD6018P-W.
  2. Set the communication interface to WIFI in the device's System Settings and restart.
  3. Ensure your mobile phone is connected to the same 2.4G WiFi network as the device.
  4. Open the APP, add the device, and follow the network distribution steps to connect.
  5. The APP may require location services and other permissions. Grant them for full functionality.

APP Operation: The app allows you to monitor and control the power supply, set output voltage/current, and export data. If the network connection fails, power off the module and re-operate. For Huawei phones, turn off the random MAC address function.

7.9 PC Software Instruction

The PC software allows monitoring and control of the power supply from a computer. It supports Windows 7-10 systems.

Video: Product overview and function demonstration, including PC software interface.

PC Software Download:

  • Download the PC software from this link.
  • Unzip the files to a local disk (e.g., Disk D).
  • Install the CH341SER driver first.
  • Run Net framework4.7.2.exe to install the .Net environment.
  • Run RidenPowerSupply.exe to use the software.

PC Software Connection:

  • USB Connection: Set the RD6018P communication interface to USB. Connect the device to your PC via a Micro USB cable. The PC software should prompt that the serial port has been updated. Click "Connect".
  • WiFi Connection (RD6018P-W only): Set the device's communication interface to WiFi and restart. On the PC software, click "WiFi Network" to open the configuration interface. Click "Initialize", then enter your WiFi name and password, and click "Network distribution". After successful connection, click "Connect".

PC Software Functions: The software provides basic functions like voltage/current preset, data group quick call out, calibration, brightness setting, and voltage/current curve exporting. You can monitor and control the power supply, program output sequences, and perform firmware updates.

8. Maintenance

8.1 Firmware Update

It is recommended to keep your device's firmware updated for the best performance and features. Firmware updates can be performed via the PC software.

Procedure:

  1. Press and hold ENTER and power on the RD6018P to enter boot mode.
  2. Connect the device to your computer via USB.
  3. In the PC software, navigate to the "Firmware Update" section.
  4. Click "Firmware Update". A prompt will appear; click "Now" to upgrade.

Note: Firmware updates are not supported under WiFi connection mode. If the device cannot start normally, always update in boot mode.

8.2 Boot Logo Update

You can customize the boot logo of your device using the PC software. Click "Start Logo Update" in the PC software, then select a picture file. Some logo samples are included in the installation package.

8.3 Software Version Update Detection

The PC software can automatically detect if a new version is available. Click "Software Update" in the PC software, and an update prompt will appear if a new version is found.

9. Troubleshooting

This section addresses common issues and protective measures of the RD6018P.

  • Over-Voltage Protection: If the input voltage exceeds 72V, the device will prompt an "Overvoltage at Input!" warning. If the input voltage exceeds 75V, the power supply will automatically cut off output to prevent damage. The device can withstand up to 100V DC input for a short time, but you must disconnect it promptly.
  • Input Reverse Connection: If the input is reverse connected (e.g., -50V), the device will not power on. Correct the connection for normal operation.
  • Battery Power Reverse: If a 12V battery is reverse connected to the output terminals, the indicator will light up, but the device will not be damaged.
  • Output Short Circuit: The device is designed to withstand output short circuits without damage.
  • APP/PC Software Connection Issues: Ensure the device's communication interface is correctly set (USB/WIFI). For WiFi, verify both the device and your control device are on the same 2.4G network and that the router's AP isolation and WMM functions are disabled. If using a Huawei phone, disable the random MAC address function.
  • Calibration Errors: If the measurement accuracy is not as expected, consider performing a calibration. This should only be done by experienced personnel with professional equipment.

10. User Tips

  • For quick adjustments, utilize the encoder potentiometer. For precise values, use the keypad.
  • Regularly check for firmware updates to ensure optimal performance and access to new features.
  • When using the device with a low-power power source, it's advisable to set the Max Power value to the rated power of your source to prevent overloading.
  • If you encounter issues with the mobile app, try restarting the RD6018P and ensuring your phone is on the same 2.4G network.
  • Always double-check wiring, especially when connecting batteries, to avoid potential hazards.

11. Appendix

11.1 Common Battery Voltage Comparison Table

Battery TypeNominal Voltage (V)Final Charge Voltage (V)Final Discharge Voltage (V)ApplicationCharacteristics
LiCoMnNiO23.74.23Digital DeviceHigh capacity
LiFePO43.23.652.5Electric bike/electric toolLarge discharge current, inexpensive
Lead Storage Battery1214.410.5Car/electric bikeInexpensive, Lead pollution
Dry Battery1.5Cannot charge0.9Clock/Remote controlInexpensive, widely used, not rechargeable
NiCD Battery1.251.51.1ToyInexpensive, Memory effect
Ni-MH Battery1.21.40.9Toy/ShaverNo memory effect

11.2 Common Electric Car/Bike Battery Voltage Comparison Chart

Nominal VoltageBattery TypeNumber of batteries connected in seriesFinal Discharge Voltage (V)Final Charge Voltage (V)
48VLiCoMnNiO2144258.8
LiCoMnNiO2133954.6
LiFePO4164058.4
Lead Storage Battery44257.6
36VLiCoMnNiO2103042
LiFePO4123043.8
Lead Storage Battery331.543.2
24VLiCoMnNiO272129.4
LiFePO482029.2
Lead Storage Battery22128.8

Note: If the final discharge voltage of the battery is higher than 60V, you cannot use RD6018P to charge, as it will damage the device.

12. Warranty and Support

For technical support, firmware updates, and additional resources, please refer to the official product page or contact the seller directly. Damage resulting from incorrect operation, exceeding hardware limits, or unauthorized modifications may not be covered under warranty.

A comprehensive user manual in PDF format is available for download: User Manual (PDF).


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.