1. Introduction
This manual provides comprehensive instructions for the installation, setup, operation, and troubleshooting of the VOTOL EM150SP Programmable DC Motor Controller. The EM150SP is designed for 72V systems with a rated current of 150A, featuring CAN-BUS communication and regenerative braking capabilities, suitable for motors up to 3000W.


2. Safety Warnings
Always ensure the controller is powered off before making any wiring connections or disconnections. Incorrect wiring or handling while powered on can lead to severe damage to the controller, motor, or other components, and may pose a risk of electric shock. Ensure all connections are secure and insulated. Refer to all diagrams carefully.
3. Package Contents
Upon opening your package, please verify that all components are present and undamaged:
- VOTOL EM150SP Controller
- Necessary wiring harnesses and connectors
- User Manual (PDF, referenced textually)

4. Specifications
| Feature | Specification |
|---|---|
| Model | EM150SP |
| Controller Type | DC Motor Controller |
| Rated Voltage | 72V |
| Rated Current | 150A |
| Peak Current | 380A |
| Boost Current | 200A |
| Max. Efficiency | 14400W |
| Flux Weakening | 200% |
| Waterproof Rating | IP67 |
| Net Weight | 2.03kg |
| Item Length | 200mm |
| Item Width | 110mm |
| Item Height | 65mm |
| Material | Aluminium |
| Special Features | Control, CAN-BUS, Regen Function |
| Placement on Vehicle | Rear |
5. Setup
5.1. Wiring Instructions
Carefully follow the wiring diagrams below for proper connection of the controller. Ensure all connections are secure and match the specified wire colors and functions.





5.1.1. Main Function Wiring (2x8 Connector)

5.1.2. E-lock Connector
Connects with the ignition key.
- Wire Color: Grey/Purple
- Function: E-lock (connects with ignition key)

5.1.3. Throttle Connector
Connects with throttle, display, and brake.
- Throttle 5V+: Pink
- Throttle -: Black
- Throttle Signal: Green
- Display Signal: White
- Brake Signal (12V): Purple

5.1.4. Gears Connector
Connects with the gears switch. The negative wire must be connected.
- Gear 3: Black/White
- Negative: Black
- Gear 1: Green/White
- Gear Sport: Yellow/White
- Gear Park: Brown/White

5.1.5. Back & Kick Stand Connector
Connects with the back switch and kick stand switch.
- Back (Reverse) Switch: Grey/White (Connect with GND. Press button and apply throttle for reverse rotation.)
- Kick Stand Switch: Grey/Black (Connect with GND.)

5.1.6. Restore Connector
Connects with the restore button.
- Restore Button: Brown (Double-press and long-press on second time to activate restore function when throttle/brake errors occur.)

5.1.7. Debugging Connector
Connects with PC USB cable and Bluetooth. Do not plug or unplug when the controller is powered on.
- 5V: Pink
- Negative Pole: Black
- Debugging RXD: Blue
- Debugging TXD: Orange

5.1.8. Hall Connector
Connects to the Hall sensor.
- Wire Colors: Yellow, Red, Green, Blue, Black

5.1.9. Anti-theft Connector
Connects to the anti-theft system.
- Negative Pole: Black
- Positive Pole: Red
- Power Input: Orange
- Motor Movement Signal: Yellow
- Anti-theft Signal Input: Red

5.2. Software Installation
To program and debug the controller, you need to install the necessary drivers and software on your PC.
5.2.1. Driver Installation (Non-CAN)
Connect the controller to your PC using the USB debugging cable. The driver should install automatically. If not, follow these steps:
- Decompress the file "USB-to-serial-win10-20150814", then decompress "YH-340 USB".
- Supported systems: WIN7/WIN8/WIN10. Choose the correct file for your PC system.
- Run "Setup 32.64位元" and install.
- After installation, connect the USB cable. If issues persist, right-click "My PC" and enter "PC management".
- In "Device Manager", expand "COM and LPT". If you see a port with "!", right-click it and choose "Update the driver software".
- Select "Browse my computer for driver software" and choose version 3.3.10.140 (2009-11-19).
- Once installed, the port should appear without "!".



5.2.2. Driver Installation (CAN Function)
If using the debugging cable with CAN function:
- Connect the USB cable to your PC. If internet is available, it may install automatically. Otherwise, decompress the "ft232r" driver.
- Connect the USB cable and open Device Manager. If the port shows "!", the driver needs to be installed.
- Right-click the USB Serial port and choose "Update driver software".
- Click "Browse my computer for driver software".
- Select the correct driver file and click next.
- If the port shows up correctly, the driver is installed. If "!" persists, reconnect the USB debugging cable.



5.3. Connecting Debugging Cable with Controller and PC
Once drivers are installed, connect the controller to the PC for parameter configuration.
- Select the correct USB debugging cable based on whether your controller has CAN function.
- Choose the appropriate baud rate (9600 for non-CAN, 115200 for CAN). Verify the USB port is installed correctly in Device Manager.
- Open the PC controller software. With the controller powered on, connect the correct port. All parameters should then be displayed in the software.
- If the controller cannot be connected, enter the advanced interface (type "~" and press "shift" in the error_count field) and choose the correct CAN baud rate and ID (or Auto_B).



6. Operating Instructions
6.1. Parameter Setting Description
The controller software allows for detailed configuration of various operational parameters. After adjusting parameters, click "Param write" to save changes to the controller, or "save prarm" to save to the computer.

6.1.1. Parameter Page 1
- Baudrate: Select 9600 (without CAN) or 115200 (with CAN).
- Voltage Settings: Set overvoltage, undervoltage, soft undervoltage, and undervoltage variation. The software presets values for lead-acid batteries; lithium batteries require specific settings.
- Regenerative Current: Set the value according to battery support for reverse charging. If the battery does not support reverse charging, set to 0. High regenerative current can trigger BMS protection.
- Phase Current: Set based on the motor's max phase current. The limit should be less than or equal to the technical department's provided parameter. High phase current can cause MOS tube burning.
- Throttle Voltage Set: Define start, end, low protect, and high protect values for throttle operation.
- Start Torque & Combination Torque: These settings are for mid-drive motors with gearboxes to manage gear backlash.
- Rate of Rise & Rate of Decline: Adjust acceleration and deceleration speed.





6.1.2. Parameter Page 2
- Current/Flux-Weakening: Adjust Max Current, Flux-Weakening, and KI settings for motor performance. High flux weakening can lead to demagnetization.
- Automatic Logout Enablers: Set logout time (S mode function to reduce speed/current) and recovery time.
- Constant Speed/HHC: Enable/disable slope stop, constant speed, and set max limited RPM.
- Speed Limit Setting: Enable/disable speed limiting and set speed ratio.
- Three-speed: Configure low, mid, and high speed ratios, start phase current, KP, and soft start settings.



6.1.3. Parameter Page 3
- Motor Setting: Configure pole pairs, hall wire exchange, hall shift angle, and motor type (surface-mount for hub motor, V-type for mid-drive).
- Output: Set speedometer communication method (One-line or Hall Speedometer), enable/disable cruise function, and configure moving vehicle booster.
- Double Voltage Setting: Set for single voltage or low voltage as default.
- Reverse Speed Limit: Set the maximum reverse speed.
- EBS Ratio: Set electric brake regen power.
- Secure Boot: Enable/disable special soft function.



6.1.4. Advanced Page Settings
- Download Process Display: Shows actual and comparison values for controller parameters.
- Display RPM/Q Axle Voltage/D Axle Voltage: Switch to display these values.
- Calibration: Adjust voltage, current, and weak flux calibration.
- Open File/Download: Import ECU program or configuration files.
- CAN Mode: Adjust CAN debugging line baud rate and ID.
- Motor Temp Protection: Set initial, over, and max temperatures for protection.
- DAMPING: Prevents motor auto-rotation failure.
- Port Interface: Select port functions according to vehicle needs and technical documentation.





6.1.5. Display Page Settings
The display page shows real-time data and fault information.
- RPM: Displays motor speed.
- Voltage: Displays controller voltage.
- Current: Displays controller current.
- Controller Status: Shows fault code, controller temp, external temp, temp coefficient, gears, and connection status.




7. Troubleshooting
7.1. Error Codes
The following tables list common error codes and their meanings to assist in troubleshooting.
| Error Code | Description |
|---|---|
| 0x001 | Brake |
| 0x02 | Hardware overcurrent |
| 0x04 | Under voltage |
| 0x08 | Hall error |
| 0x10 | Over voltage |
| 0x20 | Controller error |
| 0x40 | Motor block error |
| 0x80 | Throttle error |
| 0x100 | Run away |
| 0x200 | EEPROM writing |
| 0x800 | Quality inspection failure |
| 0x1000 | Controller overheat |
| 0x2000 | Software overcurrent |
| 0x4000 | Throttle failure |
| 0x8000 | Current sensor error 1 |
| 0x10000 | Current sensor error 2 |
| 0x20000 | Brake failure |
| 0x40000 | Hall error |
| 0x80000 | Driver failure |
| 0x100000 | MOS tube short circuit |
| 0x200000 | Phase wire connection failure |
| 0x400000 | Phase wire short circuit |
| 0x800000 | Controller failure |
| 0x1000000 | Pre-charge failure |
| 0x8000000 | Motor overheat |
| 0x80000000 | SOC 0 error |

| Error Code | Description |
|---|---|
| 0x24 | Controller error |
| 0x12 | Throttle error |
| 0x42 | Over current |
| 0x13 | Hall error |
| 0x22 | Relay driver error |
| 0x14 | Under voltage |
| 0x21 | Controller overheat |
| 0x23 | CAN communication timeout |
| 0x25 | Pre-charge error |
| 0x31 | Sensor communication error |
| 0x32 | Sensor error |
| 0x33 | Motor overheat |
| 0x34 | Radiator overheat |
| 0x35 | Motor block error |
| 0x43 | Relay error |
| 0x11 | Other (High level blinks quickly, low level blinks slowly) |

7.2. After-Sale Analysis
For detailed after-sale analysis and support, please refer to the dedicated "售后故障数据库.xlsx" file, which contains further diagnostic information.

8. User Tips
- Always ensure the controller is powered off before connecting or disconnecting any wires to prevent damage.
- If you encounter difficulties during setup or programming, do not hesitate to contact the seller's support for assistance.
- Note that this manual specifically covers the EM150SP model. If you have a different version (e.g., 200SP), some specifications or instructions may vary.
9. Warranty and Support
For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact your vendor directly. Ensure you retain your purchase records for any warranty claims.