EZAIOT Smart Radiator Thermostatic Valve

Contents

EZAIOT Tuya Smart Radiator Thermostat User Manual

Model: Smart Radiator Thermostatic Valve

1. Introduction

Thank you for choosing the EZAIOT Smart Radiator Thermostatic Valve (TRV). This device allows you to intelligently control your home's heating system, providing comfort and energy efficiency through smart app and voice control. This manual provides detailed instructions for installation, operation, and troubleshooting to ensure optimal performance of your TRV.

EZAIOT Smart Radiator Thermostat with key features
EZAIOT Smart Radiator Thermostat highlighting Voice Control, Silent Operation, Anti-Frost Function, Weekly Programming, and Low Power Consumption.

2. Safety Instructions

  • This product is designed for controlling water heating systems only.
  • Avoid exposing the device and its batteries to high temperatures and humidity.
  • If you observe any unusual issues such as overheating, leaks, or strange smells, immediately stop using the device and contact a qualified professional.
  • Do not attempt to disassemble or repair the device yourself.

3. Package Contents

Please check the box for the following items:

  • Smart Radiator Thermostatic Valve (TRV)
  • Adapter Set (for various valve types)
  • User Manual (this document)

4. Technical Specifications

FeatureSpecification
Power Supply3 x 1.5 V Alkaline AA Batteries (LR6)
Standby Current6 μA Min
Operating Temperature0~50 °C (For indoor use only)
Storage Temperature-20~70 °C
Wi-Fi Protocol802.11b/g/n (2.4 GHz)
Wi-Fi Range200m+ in open field
Temperature SensorNTC, B=3380, R25=10 KΩ 1%
Protection LevelIP20
Max Surface Temperature90 °C (at the radiator)
Connection Thread SizeM30 x 1.5 mm / M28 x 1.5 mm
Linear Travel6 mm
CompatibilityCompatible with most radiators on the market
Dimensions (W x H x D)59.4 mm x 94.7 mm x 59.4 mm
Weight145 g
Communication Protocol2.4GHz WiFi / Tuya Zigbee 3.0
APP ControlTuya Smart / Smart Life
Voice ControlGoogle Home, Alexa, Yandex Alice

5. Device Overview

Familiarize yourself with the components of your TRV:

  • Union Nut: For attaching to the heating valve.
  • Battery Compartment: Houses the AA batteries.
  • Set Button: Used for screen orientation adjustment.
  • LED Light: Indicates device status (network, heating, modes, low battery).
  • Lock Display: Shows child lock status.
  • Knob Button: Used to adjust temperature and navigate menus.
  • Middle Button: Used for mode switching, confirmation, and special functions.

Indicator Light Meanings:

  • Normal Display: Usually shows room temperature.
  • 'Set' Indicator Lit: Target temperature is displayed.
  • Off (No Mains Connection): LED is off.
  • Flashing (Network Connection): Device is connecting to the network.
  • Solid On (Network Connected): Network connection successfully established.
  • Heating Symbol: Device is actively heating.
  • Programming Mode Symbol: Device is in programming mode.
  • Comfort Mode Symbol (Default 20 °C): Device is in comfort mode.
  • ECO Mode Symbol (Default 15 °C): Device is in energy-saving mode.
  • Anti-Frost Mode Symbol (Default 5 °C): Device is in anti-frost mode.
  • 'E1' Symbol: Valve Calibration Failed.
  • Flashing Battery Symbol: Battery power is less than 20%, replacement recommended.

6. Setup

6.1. Battery Installation

  1. Press the battery compartment latch and slide the lid down to remove it.
  2. Insert 3 new LR6 AA alkaline batteries into the compartment, ensuring correct polarity.
  3. After installing batteries, the device will display '---'. Briefly press the 'Set Button' to adjust the screen orientation if needed.
  4. Reattach the battery compartment cover and latch it into place.

Important Note: Use LR6 alkaline batteries. Choose new, high-quality batteries and check levels regularly. Replace batteries promptly when the TRV or app indicates low battery.

6.2. Adapter Installation

First, check if your radiator valve interface is M30 x 1.5 mm. If it is, you can directly install the TRV. If not, an adapter is required.

  1. Identify your valve's connector type (e.g., Danfoss RA, RAV, RAVL, Caleffi, Giacomini, M28).
  2. Select the appropriate adapter from the provided set.
  3. Firmly screw the adapter onto your valve, ensuring it is properly secured for correct operation.

6.3. Thermostat Installation

  1. Wait for the '---' animation to complete. When you see the '---' animation loading, it indicates the device is initializing.
  2. After the '---' loading animation ends, use the valve nut to attach the device to the radiator.
  3. Once attached, quickly press the 'Middle Button'. The screen will display 'Ad', indicating the device is adapting to the valve. This process takes approximately 5-20 seconds.
  4. When adaptation is successful, the screen will display the initialized screen.

Important: It is essential to install the valve before pressing the Middle Button for adaptation. Otherwise, the screen will display 'E1'.

Troubleshooting 'E1' Symbol:

If 'E1' appears, check the installation location, connection security, and valve body compatibility. Then, try one of the following calibration methods:

  • Method 1 (Manual): Remove and reinstall the battery to restart the device. Repeat Step 3 of installation.
  • Method 2 (App): Complete network setup first (see 6.4), then follow app instructions for calibration.

Attention: Recalibration requires restarting power. Ensure stable power supply. If 'E1' persists, contact support.

6.4. App Download & Device Connection

Smart App & Voice Control diagram
Remote App Control and Voice Control integration with Tuya Smart, Alexa, and Google Home.

6.4.1. Download the Smart Life App

Search for 'Smart Life' in the App Store (iOS) or Google Play Store (Android) and download the app.

6.4.2. Enter Network Configuration Mode

  1. Turn the device's 'Knob Button' counter-clockwise until 'OF' appears on the display.
  2. Press and hold the 'Middle Button' for a minimum of 3 seconds. When '---' begins a circular animation on the display, the device has successfully entered network configuration mode.

6.4.3. Add Device via App

Attention: Ensure your phone's Bluetooth and Wi-Fi are on, and the Smart Life app has Bluetooth access permissions.

  1. Open the app's 'Home' interface, tap '+' in the upper right corner, and select 'Add Device'.
  2. The system will automatically search for and find the device. Tap 'Add'.
  3. Select your 2.4 GHz Wi-Fi network and enter the password, then tap 'Next'.
  4. Wait for the device to be successfully added, then tap 'Done' to complete the installation.

7. Operation

7.1. Temperature Setting

Rotate the 'Knob Button' to adjust the target temperature in 0.5°C increments.

7.2. Temperature Control Modes

Short press the 'Middle Button' to switch between the four standard modes and programming mode.

Standard Modes:

  • Comfort Mode (Default: 20 °C): Maintains an ideal indoor temperature for comfort.
  • ECO Mode (Default: 15 °C): Energy-saving mode, maintaining temperature slightly below comfort to prevent waste.
  • Anti-frost Mode (Default: 5 °C): Prevents pipe freezing by maintaining a safe temperature, ideal for absences or cold climates.
  • OFF Mode: Closes the valve when heating is not required. To set, turn 'Knob Button' until 'OF' appears, or short press 'Middle Button' to cycle modes.

Programming Mode:

Smart Weekly Scheduling interface
App interface for Smart Weekly Scheduling, showing Comfort, ECO, and Anti-Frost temperature settings.

When the screen shows the programming symbol, the device is in programming mode. Configure temperatures and schedules via the mobile app. Set up to 6 programs daily with options for Comfort, ECO, Frost Protection, and Custom modes.

Custom Mode:

When in any standard mode, rotating the 'Knob Button' activates custom mode. The temperature setting will remain constant until manually changed again.

Attention: Programming Mode, Vacation Mode, and Boost Mode are temporarily disabled until network setup is completed.

7.3. Special Features

  • Frost Protection Function: If enabled in software settings, the device automatically activates frost protection (valve opens below 5°C, closes above 7°C) even in OFF mode.
  • Vacation Mode: (App only) Used when away. Specify duration, and the device switches to anti-freeze mode. Displays 'HO'. To exit manually, press and hold 'Middle Button' for 3 seconds.
  • Boost Mode: (App only) Temporarily sets the device to full heat for a specified duration. Displays '60'. To exit manually, press and hold 'Middle Button' for 3 seconds.
  • Activating Switch-On Mode & Heating Pause: Turn 'Knob Button' clockwise until 'On' appears to fully open the valve. In winter, this forces heating. In summer, it allows the valve's internal spring to retract, extending lifespan.
  • Screen Display Rotation: Tap the 'Set Button' to change the screen orientation.
  • Child Lock Function: Locks device operation to prevent unintentional changes. To enable/disable, press and hold 'Middle Button' for 3 seconds; 'LC' (locked) or 'UL' (unlocked) will appear.
  • Detection of Window Opening: If room temperature drops over 1.5°C in 5 minutes while heating, the device activates window detection and stops heating. The valve closes for 30 minutes, and 'OP' appears. Detection cancels if temperature rises, mode changes, or after 30 minutes.
  • Anti-limescale Protection: The device automatically turns on every Monday at 12:00 p.m. for maintenance to prevent valve calcification. 'CA' appears on the screen during this time.
  • Restoring Factory Settings: Press and hold 'Middle Button' while inserting batteries until 'FA' appears and blinks for 3 seconds. All previous settings will be lost.
  • Power Failure Memory Function: The device retains its current working mode and resumes it after a power failure.

7.4. System Modes (For App Use Only)

Dual control mode options
Dual control mode options: PID for energy-efficient precision and ON/OFF for simplicity.
  • ON-OFF Mode: Valve operates fully open (100%) or fully closed (0%). Position remains fixed.
  • PID Mode: Valve continuously adjusts its opening percentage for gradual temperature alignment, maintaining comfort with minimal fluctuations. PID mode typically consumes more energy.

7.5. Switching Hysteresis (For App Use Only)

Range: 0.5-5°C. Reduces frequent switching by allowing downward deviation (e.g., 25°C target, 0.5°C hysteresis: heating activates at 24.5°C, deactivates at 25°C). Only adjustable in ON-OFF mode.

7.6. Calibration (For App Use Only)

Adjust the device's temperature measurements for accurate readings. Navigate to Settings > Temperature > Calibration in the app and adjust as needed.

7.7. Voice Control

The TRV supports voice commands via Amazon Alexa and Google Home. Ensure temperature units are consistent between the device and smart speaker.

  • General Commands: