1. Introduction
The PowMr POW-LVM5K-48V-N is an advanced all-in-one hybrid solar inverter designed for energy storage and power conversion. It integrates solar energy storage, municipal power charge storage, and AC sine wave output capabilities. This model is specifically designed to output 110VAC/120VAC, making it suitable for regions such as the United States, Brazil, and Japan.
Key Features:
- Pure Sine Wave inverter with 120Vac AC output.
- High output power up to 5000W, supporting single-phase devices.
- Fast switching time of 10ms for seamless power transfer.
- Compatible with 24V/48V lithium-ion and lead-acid batteries, with user-definable settings.
- Maximum PV charging current up to 80A.
- Maximum AC charging current up to 40A.
- Maximum hybrid charging current up to 80A.
- Wide AC input voltage range of 90~140Vac.
- Broad PV input voltage range of 120~450Vdc for flexible solar panel configurations.
- Equipped with 1 MPP Tracker, boasting 99.9% efficiency.
- Multiple communication interfaces: USB, CAN, RS485 (with optional WiFi/GPRS), and Dry node control.
- Durable finish with high anti-corrosion properties.
- Effective forced air cooling system ensures stable equipment operation.
Product Overview Video:
This video provides a brief unboxing and overview of the PowMr 5000W 48V MPPT Hybrid Solar Inverter, highlighting its key features and applications.
2. Specifications
| Category | Parameter | Value |
|---|---|---|
| General | ||
| Model Number | POW-LVM5K-48V-N | |
| Brand Name | PowMr | |
| Certification | CE | |
| Origin | Mainland China | |
| Is Smart Device | Yes | |
| Dimensions (L*W*D) | 426mm*322mm*126mm (16.77in H, 12.68in W, 4.96in D) | |
| Weight | 11.5KG | |
| Noise | ≤60dB | |
| Hign-concerned Chemical | None | |
| is_customized | Yes | |
| AC Mode (Input) | ||
| Rated Input Voltage | 110/120Vac | |
| Input Voltage Range | 90Vac-140Vac | |
| Frequency | 50Hz/60Hz (auto-sensing) | |
| Overload/Short-circuit Protection | Circuit breaker | |
| Efficiency | >95% | |
| Maximum Bypass Overload Current | 63A | |
| Inverting Mode (Output) | ||
| Output Type | SINGLE | |
| Output Voltage Waveform | Pure sine wave | |
| Rated Output Power (VA) | 5000VA | |
| Rated Output Power (W) | 5000W | |
| Rated Output Voltage (Vac) | 120Vac | |
| Maximum Efficiency | >90% | |
| Peak Power | 10000VA | |
| Loaded Motor Capability | 4HP | |
| Rated Battery Input Voltage | 48V (minimum start voltage 44V) | |
| Power Saving Mode | Load ≤50W | |
| AC Charging | ||
| Battery Type | Lead acid or lithium battery | |
| Maximum Charge Current (settable) | 0-40A | |
| Charge Voltage Range | 40–60Vdc | |
| Breaker Specification | 63A | |
| Solar Charging | ||
| Maximum PV Open-Circuit Voltage | 500Vdc | |
| PV Operating Voltage Range | 120-500Vdc | |
| Battery Voltage Range | 40-60Vdc | |
| Maximum Input Power | 5500W | |
| Charge Current Range of Solar Energy (settable) | 0-80A | |
| Communication | ||
| Communication Interface | USB/RS485 (WiFi/GPRS)/Dry node control | |
3. Product Components
Familiarize yourself with the various components and ports of your PowMr Hybrid Solar Inverter:

Diagram showing the front and rear panel components of the inverter.
Front Panel:
- LCD Buttons: For navigating menus and making selections.
- Mounting Holes: For secure installation of the inverter.
- LCD Screen: Displays real-time charging information, system status, and settings.
- LED Indicators: Provide visual status updates (e.g., AC, Charge, Fault).
- AC Input Breaker: Protects the AC input circuit.
Rear Panel:
- Dry Contact Port: For external control or signaling.
- RS485 Communication Port: For data communication with other devices.
- USB Debugging Port (Internal Use): For service and diagnostics.
- AC Input Terminal: Connects to the utility grid or generator AC input.
- AC Output Terminal: Connects to household loads.
- Cooling Fans: Dissipate heat to maintain optimal operating temperature.
- PV Input Terminal: Connects to the solar panel array.
- Main On/Off Power Switch: Controls the main power to the inverter.
- Battery Input Terminal: Connects to the battery bank.
- Grounding Lug: For connecting the protective earth ground.
4. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your solar inverter. Please follow these guidelines carefully. It is recommended that installation be performed by a qualified professional.
Wiring Diagram:
The following diagram illustrates the typical wiring connections for the PowMr Hybrid Solar Inverter. Ensure all connections are secure and follow local electrical codes.

Detailed wiring diagram for connecting the inverter to solar panels, battery bank, utility grid, generator, and household appliances. Note: This diagram is for reference ONLY, and the wiring method is determined by the actual situation.
Connection Details:
- AC Input: Connect to Generator or Utility. Max AC Bypass Current: 63A. Max AC Charge Current: 40A. Recommended AC Wire: 7AWG. Always connect the PE protective conductor (Ground) first.
- AC Output: Connect to household loads (e.g., washing machine, TV, refrigerator). AC Output Power: ≤ 5000W. Rate Voltage: 120Vac ± 5%. Rate Current: 41.7A.
- PV Input: Connect to Solar Panel Array (all in series). Max PV Input Power: ≤ 5500W. Max PV Input Current: ≤ 22A. Start-up Voltage: > 150V. Total Open Circuit Voltage (VOC): ≤ 500V. Recommended PV Wire: 10AWG.
- Battery: Connect to 48V Lithium or Lead-acid battery bank. Recommended battery capacity: 200AH. Recommended Battery Wire: 2AWG. Max Charge Current: 80A. The battery MUST be connected for proper operation.
Appliance Compatibility:
The inverter is compatible with a variety of daily appliances. Refer to the table below for guidance on load power and inverter selection. Always ensure that the inverter's capacity matches or exceeds the starting impulse current of your equipment.

This image displays common household appliances and a table guiding the selection of inverter models based on load type and power requirements. Note: Different types of loads have different starting impulse currents. The values are for reference ONLY. Customers need to select the appropriate inverter model according to the actual equipment power, current, and load characteristics.
| S/N | Load Type | Start Impact Coefficient | Minimum Continuous Output Power of Inverter Recommended | Example |
|---|---|---|---|---|
| 1 | Resistive load | 1 | P | Electric Soldering Iron, Resistance Stove, Oven, Water Heater, Disinfection Cabinet, Rice Cooker, etc. |
| 2 | Inductive Load | 3-10 | S=P*η | Electric motors, Refrigerators, Transformers, Air conditioners, Electric drills, Lawn mowers, Range hoods, Vacuum cleaners, Washing machines, etc. |
| 3 | Resistive load | 3-5 | TV, Computer host, Display projector, etc. | |
| 4 | Mixed load | 1.5-3 | Induction cookers, Hair dryers, Microwave ovens, etc. |
5. Operating Modes
The inverter offers various charge and output modes to optimize energy management based on your preferences and available power sources.

Visual representation of the inverter's charge and output priority modes.
Charge Modes:
- Photovoltaic Priority: Solar charging is prioritized. Mains power is used only when photovoltaic power is insufficient or unavailable.
- Mains Supply Priority: Mains supply is the primary charging source. Solar power is used as a backup.
- Mixed Charge: Utilizes both solar and mains power for charging, prioritizing solar when available and supplementing with mains as needed.
- Only Solar: Exclusively uses solar energy for charging, maximizing renewable energy utilization.
Output Modes:
- PV Priority: Prioritizes power from solar panels to supply the load. Switches to utility or battery if PV power is insufficient.
- Utility Priority: Prioritizes power from the utility grid. Switches to battery or PV only when the utility grid is unavailable.
- Inverter Priority: Prioritizes power from the battery bank. Switches to utility or PV when the battery voltage is low.
- Mixed Functions Mode: When the battery is not available or fully charged, the load is supplied by a combination of PV and commercial power, with PV providing maximum output.
Monitoring and Control:
The inverter can be monitored and controlled via the SmartESS App. An optional Wi-Fi/GPRS data acquisition module (purchased separately) is required for this functionality.

Monitor and control your inverter settings and performance using the SmartESS App. The Wi-Fi/GPRS data acquisition module needs to be purchased separately.
6. Maintenance
To ensure the longevity and optimal performance of your PowMr Hybrid Solar Inverter, regular maintenance is recommended.
Cooling System:
The inverter features an intelligent variable speed fan system that adjusts its rotation speed based on ambient temperature and environmental conditions. Ensure that the cooling vents are not obstructed to allow for proper airflow.

The intelligent variable speed fan will adjust the fan rotation speed according to the ambient temperature as well as the environmental conditions.
General Maintenance Tips:
- Keep the inverter clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Periodically check all wiring connections to ensure they are tight and free from corrosion.
- Ensure the inverter is installed in a well-ventilated area, away from direct sunlight, moisture, and flammable materials.
- Monitor the LCD display and LED indicators for any fault codes or unusual behavior.
- If using lead-acid batteries, perform regular maintenance as recommended by the battery manufacturer.
7. Troubleshooting
This section provides general guidance for common issues. For complex problems, please contact customer support.
Common Issues and Solutions:
- No Power Output:
- Check if the main ON/OFF power switch is in the 'ON' position.
- Verify AC input and output connections.
- Ensure the battery is properly connected and charged.
- Check the AC input breaker for trips.
- No Solar Charging:
- Ensure solar panels are connected correctly to the PV input terminals.
- Check PV operating voltage and open-circuit voltage against specifications.
- Verify there is sufficient sunlight.
- Overload Warning:
- Reduce the connected load to within the inverter's rated output power.
- Check the starting impulse current of connected inductive loads.
- Unusual Noise/Overheating:
- Ensure cooling fans are operating and not obstructed.
- Verify proper ventilation around the inverter.
- If noise persists or overheating is severe, power down the unit and contact support.
8. User Tips
No specific user tips were available from customer reviews or Q&A for this product at this time.
9. Warranty and Support
Your PowMr Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use conditions.
Customer Support:
For any technical assistance, troubleshooting, or warranty claims, please contact our customer support team. All inquiries will be answered within 24 hours.
Please have your product model number (POW-LVM5K-48V-N) and purchase details ready when contacting support.